• 제목/요약/키워드: standard interface

검색결과 1,022건 처리시간 0.026초

음성기반 멀티모달 인터페이스 및 표준 (Speech Based Multimodal Interface Technologies and Standards)

  • 홍기형
    • 대한음성학회지:말소리
    • /
    • 제51호
    • /
    • pp.117-135
    • /
    • 2004
  • In this paper, we introduce the multimodal user interface technology, especially based on speech. We classify multimodal interface technologies into four classes: sequential, alternate, supplementary, and semantic multimodal interfaces. After introducing four types of multimodal interfaces, we explain standard activities currently being activated.

  • PDF

User interface for remote control robot

  • Kim, Gi-Oh;Jeon, Jae-Wook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.52-56
    • /
    • 2005
  • The recent growth of the robot technology has made robots be popular and provides people with many opportunities to apply various robots. But most robots are controlled by its unique program, users feel hard and unfamiliar with robot. Therefore we need to find ways to make user feel comfortable and familiar with the usage of robot. First we will analyze how the user interacts with the robot. Next we will discuss a standard human-robot interface provide more usability with that analysis. In this paper, 10 degree of the Level Of Autonomy(LOA) are proposed. It is evaluated that what interface components and designs are proper to each LOA. Finally we suggest a way to design the standard human-robot interface for remote controlleds robot through handheld devices like the Personal Digital Assistant(PDA) and smart phone.

  • PDF

자동열차방호장치와 건널목보안장치간의 인터페이스 안전요구사항에 관한 연구 (A Study on Safety Requirement of ATP/LCS Interface)

  • 신덕호;이재훈;이기서
    • 한국철도학회논문집
    • /
    • 제8권2호
    • /
    • pp.161-169
    • /
    • 2005
  • In this paper, we provide safety requirements and advices to guarantee the safety of an interface in a level crossing system which is an interface between the conventional facilities and the new ATP (Automatic Train Protection) system, as well as we accomplish a safety management for the facilities of a country that has a different standard with already standardized ATP system. The system model has been made based on a safety activity of the international standard, and then a tolerance of a risk by the safety activity through PHA (Preliminary Hazard Analysis) has been analyzed. finally we achieved HIA (Hazard Identification and Analysis) for the assumptions that have been produced from a operating scenario and a functional interface. Thus, the safety requirements for the interface has been provided from the safety plan of HIA, and we showed the safety activity to guarantee the system safety through HIA which was depend on the design.

흙-토목섬유 Interface 특성에 관한 연구 (A Study on the Characteristics of the Soil-Geotextile Interface)

  • 고홍석;고남영;홍순영
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.82-93
    • /
    • 1991
  • The objective of this paper is to show that the soil-geotextile interaction needs to he addressed in addition to the usual tensile and modulus properties when the geotextile is being designed for a specific application. The soil-geotextile interaction can be directly assessed by standard direct shear test. The data presented here show that the shear strength paramaters describing the soil-geotextile interface can he greatly influenced by the type of the geotextile. In this investigation, we examined nine different geotextiles of varying construction and surface textures with two standard soil, under five loading conditions, and compared the shear strength and the frictional resistance with the corresponding values of soil itself The following conclusions were drawned from this study. 1. The shear stress-strain curve shows that there are the residual shear stresses at the soil-geotextile interface. Because of the hydraulic gradient between the soil and the geotextile, the excessive pore water can migrate into the geotextile and among the filaments and dissipate through the soil-geotextile interface. 2. The shear strength of the soil-geotextile interface is affected by the moisture content of the soil. At moisture content lower than the optimum water content of the Proctor compaction test, the shear strength of the soil-geotextile interface is greater. 3. The type and surface roughness of the geotextile have the greatest influence on the interface friction angle between the soil and the geotextile.

  • PDF

역사내 기존 시스템 인터페이스 방안 (A Plan of Existing System Interface within Station)

  • 이원재;안태기;신정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

Gas-liquid interface treatment in underwater explosion problem using moving least squares-smoothed particle hydrodynamics

  • Hashimoto, Gaku;Noguchi, Hirohisa
    • Interaction and multiscale mechanics
    • /
    • 제1권2호
    • /
    • pp.251-278
    • /
    • 2008
  • In this study, we investigate the discontinuous-derivative treatment at the gas-liquid interface in underwater explosion (UNDEX) problems by using the Moving Least Squares-Smoothed Particle Hydrodynamics (MLS-SPH) method, which is known as one of the particle methods suitable for problems where large deformation and inhomogeneity occur in the whole domain. Because the numerical oscillation of pressure arises from derivative discontinuity in the UNDEX analysis using the standard SPH method, the MLS shape function with Discontinuous-derivative Basis Function (DBF) that is able to represent the derivative discontinuity of field function is utilized in the MLS-SPH formulation in order to suppress the nonphysical pressure oscillation. The effectiveness of the MLS-SPH with DBF is demonstrated in comparison with the standard SPH and conventional MLS-SPH though a shock tube problem and benchmark standard problems of UNDEX of a trinitrotoluene (TNT) charge.

동기 병렬연산을 위한 응용수준의 결함 내성 연산시스템 (An Application-Level Fault Tolerant System For Synchronous Parallel Computation)

  • 박필성
    • 인터넷정보학회논문지
    • /
    • 제9권5호
    • /
    • pp.185-193
    • /
    • 2008
  • 대규모 병렬 시스템의 MTBF(moon time between failures)는 아주 짧아 겨우 수 시간 단위에 불과하여 장시간의 연산 도중 연산 실패로 끝나 소중한 계산 시간이 낭비되는 경우가 많다. 그러나 현재의 MPI(Message Passing Interface) 표준은 이에 대한 대안을 제시하지 않고 있다. 본 논문에서는, 비표준의 결함 내성 MPI 라이브러리가 아닌 MPI 표준 함수들만을 사용하여, 일반적인 동기 병렬 연산에 적용할 수 있는 응용 수준의 결함 내성 연산 시스템을 제안한다.

  • PDF

에이전트 인터페이스 및 응용 서비스 개발 (A Study on the Development of Agent Interface and Agent Application Service)

  • 이길흥
    • 정보처리학회논문지C
    • /
    • 제10C권4호
    • /
    • pp.493-500
    • /
    • 2003
  • 본고에서는 에이전트의 제어 및 관리를 위한 인터페이스 표준과, 각 인터페이스에 필요한 메시지를 구현하였다. 에이전트 인터페이스는 에이전트, 에이전트를 생성하고 활동 토대를 제공하는 에이전트 시스템, 서비스를 요구하는 클라이언트, 서비스를 중재하는 에이전트 매스터, 망내의 에이전트 관리 기능을 수행하는 에이전트 관리자 사이의 메시지 교환으로 정의된다. 이러한 인터페이스 표준은 OMG의 MAF와 FIPA의 에이전트 표준을 반영하여 만들어 졌으며, 논문에서 정의한 인터페이스와 메시지를 이용한 응용을 구현하여 실험하였다 실험 망은 컨텐츠를 분배해주는 망을 에이전트로 구현한 망으로서, 에이전트 인터페이스를 통해 이를 제어하고 관리하였다.

CMOS IC-카드 인터페이스 칩셋 (A CMOS IC-Card Interface Chipset)

  • 오원석;이성철;이승은;최종찬
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1141-1144
    • /
    • 2003
  • For proper communication with various types of IC-Card, multiple IC-Card interface complying with the IC-Card standard (ISO7816) is embedded and realized as a peripheral on the 32-bit RISC based system-on-a-chip. It provides the generation of either 3.3V or 5V power supply for the operation of the inserted IC-Card as well. IC-Card interface is divided into an analog front-end (AFE) and a digital back-end (DBE). The embedded DC-DC converters suitable for driving IC-Cards are incorporated in the AFE. The chip design for multiple IC-Card interface is implemented on a standard 0.35${\mu}{\textrm}{m}$ triple-metal double-poly CMOS process and is packaged in a 352-pin plastic ball grid array (PBGA). The total gate count is about 400,000, excluding the internal memory. Die area is 7890${\mu}{\textrm}{m}$ $\times$ 7890${\mu}{\textrm}{m}$.

  • PDF

현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 - (Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 -)

  • 김선칠
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF