• Title/Summary/Keyword: standard impact source

Search Result 84, Processing Time 0.025 seconds

Comparison of the Standard Floor Impact Sound with Living Impact Source by Subjective Evaluation

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • In the previous test, the verification of the standard floor impact source was carried out comparing the physical characteristics with living impact sources. The result was appeared the validation of the standard impact source was very low because of differences of physical characteristics. This study aims to evaluate annoyance and loudness of standard impact source which is used for the measurement of floor impact sound, and to compare the annoyance and loudness of living impact sources which are produced in real life. The impact sources considered are tapping machine, tire and impact ball as standard sources, and nine real sources which were chosen from the existing researches. The result showed differences of annoyance and loudness between standard impact sources and living impact sources, which means the standard impact sources may rate the performance of floor system inappropriately. In the future, the rating method should be examined how the standard impact sources are similar with real sources in the point of rating the performance of floor system.

Verification of Effectiveness of the Standard Floor Impact Source by Comparing with Living Impact Sources (실생활 충격소음을 통한 표준 바닥충격원의 실효성 검증)

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.12
    • /
    • pp.1117-1126
    • /
    • 2013
  • The standard impact sources, standardized to rate the sound insulation performance of floor structure, should simulate well the real floor impact sources, which is very important to grade the floor structure then to establish counter plan to improve the performance of floor. Recently the tire, the standard heavyweight impact source, has been discussed that the impact force is too big to represent the real impact force. And researches have been carried on the applicability as a substitute or a supplementary. In addition, tapping machine, the standard lightweight impact source, is also questionable if it is representative of real lightweight impact source. This study aims to examine the similarity of standard impact sources with living impact sources, comparing the physical characteristics such as impact force, frequency contents and sound level. The result showed that the physical characteristics of standard impact sounds were somewhat different with that of living impact sounds, and the standard sources couldn't be verified from this result. Later subjective evaluation should be followed to compare how the physical differences make relationship with the subjective differences.

Comparison of Standard Floor Impact Sources with a Human Impact Source (바닥충격음 측정용 표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Park, Jun-Hong;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.789-796
    • /
    • 2006
  • The characteristics of the four standard floor impact sources (impact ball, bang machine, tapping machine, modified tapping machine) and a human impact source (jumping children) were investigated. First, the mechanical impedance of each source were evaluated. Then, the impact force exposure level of each source were measured. The results showed that fundamental frequency and impedance produced by the impact ball are the most similar to those of the human impact source. The frequency characteristics of the impact ball were most similar to those of jumping children. Consequently, the impact ball more accurately reproduces human impact compared to the other standard impact sources. Therefore, the impact ball should be considered as the reliable impactor in evaluating floor impact noise.

Comparison of the Standard Floor Impact Source with the Human Impact Source (표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.804-807
    • /
    • 2005
  • The characteristics of the standard floor impact sources and the human impact source were investigated. First, the mechanical impedance of the each source was evaluated. Second, the impact force exposure levels and impact sounds level driven by the each source were measured. The results showed that the mechanical impedance and impact force exposure level of the impact ball are the most similar to those of the human impact source among the standard impact sources.

  • PDF

Analysis on the Vibration Transmission Characteristics of the Standard Test Building by Using Standard Impact Source (경량 및 중량 충격원에 의한 표준 실험동의 진동전달 특성 분석)

  • Jin, Pil-Hwa;Kim, Heung-Sik;Kim, Do-Heong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.371-371
    • /
    • 2006
  • The purpose of this study is to provide a fundamental data for efficient and economical reduction method and predict ion method of floor impact noise. In order to get the useful results, the measurement on the vibration transmission characteristics of standard test building with four rooms by using heavy and light-weighed impact source were carried out. In this measurement various conditions such as the change of test structure construction, the pick-up sensor location, the excitation posit ion, and the resilient material types were applied to get the vibration characteristics transmitted from excitation room to adjacent rooms.

  • PDF

Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors (실충격음과 표준충격원으로 발생된 바닥충격음의 비교)

  • Sato, Shin-Ichi;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

Korean Industrial Standard of “Rating of floor impact sound insulation for impact source in building and of building elements” (바닥충격음 차단성능 평가방법의 KS 규격화 방안)

  • 송민정;장길수;김흥식;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.383-386
    • /
    • 2001
  • The KS of “Measurements of impact sound insulation of floors” was established before the years. But the KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is not founded yet. To establish the rating measurement of floor impact sound insulation. The studies on the rating method of domestic floor system of impact sound insulation and response of its inhabitant’s were reviewed. And the rating method of ISO’s and JIS’s were studied in this consideration. The result of this study, KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is proposed.

  • PDF

Evaluation of Floor Impact Sound by Floor Coverings in Standard Test Building (표준시험동에서 바닥마감재에 따른 바닥충격음 특성평가)

  • Kim, Hak-Cheon;Kim, Yong-Gil;Kim, Sang-Chul;Lee, Hyun-Lyul;Cho, Hyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.439-440
    • /
    • 2008
  • Five floor coverings were tested with three different types of floor structures in the standard test building in order to evaluate the effectiveness of the floor impact sound reduction. The level of floor impact sound reduction is influenced by not only the types of floor coverings but interrelationship between the floor coverings and floor structures. From the tests, it was found that floor coverings were effective in reducing the floor impact sound using the light impact source. In addition, proper mixtures of the floor structure and the floor covering have shown effectiveness to a certain extent in reducing the floor impact sound using the heavy impact source.

  • PDF

A Study on the Characteristic and Reproducibility of Floor Impact Sound Source (바닥충격음원의 특성과 재현성에 관한 연구)

  • Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.3 no.4
    • /
    • pp.23-31
    • /
    • 2003
  • From 1998, the number of household who live in apartment house outnumber that of household live in detached dwelling by 0.3% in Korea. As walls and floors are shared with neighbourhood in apartment houses, percent complaints to the impact noise from the upper floor was so high that it represents an important factor in apartment indoor noise. And the rate is closely correlate with children's running, playing and jumping. In this study, comparisons of standard impact source, such as Tapping Machine and Bang Machine, with real life impact sources were made in order to investigate acoustical characteristics between them. Also reproducibility tests for impact sound sources were carried out.

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.