• 제목/요약/키워드: standard fire

검색결과 856건 처리시간 0.032초

병원 전 심정지 환자의 자발순환 회복에 관한 병원전 처치 - 하트세이버 수상자를 중심으로 - (Prehospital care after return of spontaneous circulation in out-of-hospital cardiac arrest patients: Based on Heart Saver laureate)

  • 고봉연;홍성기;김진영
    • 한국응급구조학회지
    • /
    • 제18권2호
    • /
    • pp.125-136
    • /
    • 2014
  • Purpose: We aimed to improve the survival rates of out-of-hospital cardiac arrest patients. Methods: We analyzed data regarding cardiopulmonary resuscitation (CPR) outcomes and clinical characteristics of out-of-hospital cardiac arrest patients. The data included prehospital emergency medical service reports of 207 patients, 135 patients of Heart Saver, who survived over 72 hours after return of spontaneous circulation (ROSC) in Gyeonggi-do from January, 2012 to December, 2013. Data were analyzed using SPSS 18.0 descriptive statistics. Results: Among patients who achieved ROSC, 87.6% were men and 73.6% were aged 41-70 years; 86.7% were cases of witnessed cardiac arrest, and cardiopulmonary resuscitation was performed by bystanders in 65.9% of cases. The initial electrocardiogram showed ventricular fibrillation or pulseless ventricular tachycardia in 96.3% of patients. The call time was 1.0 minutes, arrival time was 6.3 minutes, time spent at the scene was 8.0 minutes, hospital arrival time was 10.0 minutes, and total CPR duration was 9.6 minutes. The certificate of them was paramedics in 89.6%. Conclusion: To improve the survival rates of out-of-hospital cardiac arrest patients, standard prehospital care for these patients and educational programs regarding CPR for lay rescues should be developed.

스마트 디바이스를 활용한 교육시설물 자원관리 시스템에 관한 연구 (A Study on Educational Facilities Resource Management System using Smart Devices)

  • 류창수
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1013-1014
    • /
    • 2015
  • 현재 교육시설은 학교시설관리기준에 의거한 엄격한 적용과 예방교육을 함에도 불구하고 학교 안전사고는 책임의식이 매우 낮은 미성년학생들에 의한 우발적 사고와 화재 및 시설물에 관한 안전 불감증으로 인해 인적 물적 피해가 발생하고 있다. 교육시설 안전을 위해서는 신속한 업무 처리와 현장에서 손쉽게 교육시설물에 관한 전자도면 및 관련문서들을 스마트 디바이스를 통하여 다양한 방법으로 확인 할 수 있도록 하는 기술이 요구되고 있다. 본 논문에서는 안전사고 발생시 전자도면, 문서관리, 다양한 교육시설물 문서 등을 다양한 스마트 디바이를 통한 교육시설물 자원관리 시스템(EFRMS)으로 교육시설의 점검과 통제를 할 수 있도록 문서변환 기능과 해상도 고효율화, 사물인터넷(IoT) 기술를 활용하여 교육업무시스템(NEIS)과 연계한 시스템 설계를 제안하였다.

  • PDF

비(鼻)의 생리기능(生理機能)에 대한 연구(硏究) (Literatural Study on Physiological Function of Nose)

  • 허준영;강정수
    • 혜화의학회지
    • /
    • 제9권1호
    • /
    • pp.121-134
    • /
    • 2000
  • The following results obtained through studies related on nose. 1. Nose is called mingtang(明堂) mianwang(面王), as it emphasize the meaning of viewing diagnosis(望診) and is called yuanpinzhimen(元牝之門), tianpinzhimen(天牝之門), qiqizhimen(七氣之門) as it emphasize the meaning of the entrance of atmosphere flow. Because it's position is the middle of face, we call tianzhongzhiyue(天中之嶽), zhongyue(中嶽). 2. As the organ of body, nose comes under the category of lung-iron(肺金), functionally comes under the category of heart-fire(心火). Functionally we can smell oder, organically nose is the pathway of respiration and to be resonator. 3. Wuzangliufu(五臟六腑) is arranged closely around the nose. The essence of wuzangliufu(五臟六腑) reflect nose, so nose becomes the standard of coloring diagnosis(色診). 4. We call nose is feihou(肺候), but it is not connected directly between the lung channel and nose. In case of lung symptom(肺證), first of all, nose become to appear the condition of lung, the lung channel and nose is close functionally. 5. The view of channels, nose is a connection with channels of yangming(陽明), bladder(膀胱), du(督脈) directly. By the connecting of each three channels, spleen stomach heart and kidney(脾胃心腎) are connected with indirectly. As the result of the relation, nose helps for body to breathe and to circulate qi(氣) and smell. And so the nature of wuzangliufu(五臟六腑) appear to the nose. 6. Particularly, the yangming channel(陽明經), and the bladder channel(膀胱經) are important. Because air-qi(天氣) reach to kidney lung through nose, ground-qi(地氣) reach to spleen stomach through mouth and yingwei(營衛) revolve through the bladder channel(膀胱經). As the result nose becomes the essential organ of circulation of yinewei(營衛), ascent and descent of qi(氣).

  • PDF

고강성 스터드볼트의 역학적 특성에 관한 연구 (Mechanical Properties of High Stiffness Shear Connector)

  • 엄철환
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.491-496
    • /
    • 2015
  • 합성보의 쉬어코넥트로 널리 사용되고 있는 스터드볼트는 현재 학회규준에 강재의 재질은 용접성을 고려한 SS400이 규정되어 있으며, 그 전단내력의 산정식은 압축강도 $300kgf/cm^2$ 이하의 콘크리트를 대상으로 하고 있다. 한편 합성구조의 보급에 따라 합성보 뿐만 아니라 다른 구조부분에서도 강재과 콘크리트를 결합하는 쉬어코넥트 혹은 다른 용도의 접합재의 필요성과 함께 강재와 콘크리트의 고강도화, 프리캐스트화가 예상된다. 따라서 본 연구에서는 고강도 콘크리트와 강부재를 결합하기 위한 고강도 스터드의 개발을 목적으로 행하여진 일련의 실험결과를 보고하였다. 또한 스터드의 강성을 증대시키기 위한 강관을 이용한 쉬어콘넥트(이하, 파이프 스터드라고 한다)를 고안하였다. 본 논문에서는 고강도 스터드의 용접성, 역학특성에 관한 실험적 검토와 동시에 고강도 고강성 스터드인 파이프 스터드의 강성 내력을 종래의 스터드 볼트와의 비교실험을 하여 파이프 스터드의 유효성을 검증한다.

CFT 기둥용 초고강도 충전콘크리트에 관한 연구 (A Study on High Strength Concrete of Concrete Filled Steel Tube Column)

  • 정근호;임남기;이영도
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.127-132
    • /
    • 2004
  • CFT(Concrete Filled Steel Tube) is a structure of circular or squared of steel column filled with concrete. The steel tube holds the concrete inside and that makes this structure to perform superior features on stiffness, proof stress, transformation, fire resistance and construction itself. In this study, by over the 800kgf/$\textrm{cm}^2$ of high strength concrete for CFT column, research has been done on the basic property of matter such as fluidity, resistance on segregation, compressive strength, setting icons of the concrete filled in the steel tube under conditions of standard weather. Physical properties of concrete for CFT that Concrete with silica fume, fly ash of air entraining and high-range water reducing agent, that used to CFT column research purpose to find the most ideal composition, which is achieved by the investigation in the concrete's property of matter like ability of Slump, Slump Flow, Air content, Bleeding, and Settlement. For this study, experiments which are bused on obtained the result through physical test are practiced, with all of the experiment, specimens only for control are produced in each method of curing and analyzed to relations with core strength in mock-up test. In mock-up test, the research is studied compactability of concrete filled in tube and degree of hydration hysteresis, as a basic reference for applying to field of CFT column which is used over 800kgf/$\textrm{cm}^2$ high strength concrete.

경인지역 일부 5인미만 사업장 근로자의 작업환경실태와 관리대책 (The Current Status and Recommendation of Work Environment Management in Small Scale Industry with less than 5 Workers)

  • 김대식;노영만;김현욱;정춘화;유기호
    • 한국산업보건학회지
    • /
    • 제11권3호
    • /
    • pp.179-189
    • /
    • 2001
  • This study was performed to identify the current status of work environment management and to provide appropriate recommendations for small scale industry with less than 5 workers from September, 2000 to October, 2000 in Seoul city and Gyoung-gi province. The 211 companies were surveyed by checklist included the elements of management of work environment, hazardous chemicals, MSDS, personal protective equipment, and ventilation system. The proportion of metal products manufacturing and printing industries are 25.6 % and 22.3%, respectively. The daily working hours in printing industry is longer than others. The industries that produce potentially hazardous agents, such as noise, dust, metal, organic solvents, radiation and chemical material are pulp, plating, machinery, and printing, respectively. In above industries, only 2.8 % of those recognised and had MSDS. The proportion of companies providing fire extinguishers, safety showers are found to be 13.3 %, 7.1 %, respectively. Only 24.2 % of companies provided personal protective equipment to the workers. The ventilation system was operated in most of companies. But local exhaust ventilation system is provided to 22.3 % of those, also had not been annually inspected. This study showed that the current status of occupational safety and health was not appropriate for workers in small scale industries. It is suggested that annual physical examination have to be performed, MSDS usage must become widespread, and employer and emplyees in small scale industry should be educated for the treatment and storage of hazardous chemicals to improve the occupational safety and health of the working environment. also, regulatory standard has to be applied to local exhaust ventilation system in small scale industry to improve the working condition.

  • PDF

항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계 (Heat Dissipation Design for KW Class Power Control Unit Mounted on Aircraft Store)

  • 최석민;김형재;정재원;이철
    • 한국항행학회논문지
    • /
    • 제24권4호
    • /
    • pp.261-266
    • /
    • 2020
  • 항공기 장착물에 KW급 전력변환장치가 탑재되는 경우, 전력 변환 시 발생하는 대량의 발열에 대한 방열설계가 고려되어야 한다. 적절한 방열을 하지 못하는 경우, 장비 오작동 및 화재의 우려가 발생하며 이는 항공기 운항에 있어 치명적인 요인이 될 수 있다. 본 논문은 항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계에 관하여 기술하였다. 전산해석을 통한 설계 및 제작 후 시험을 수행하였으며, 고전력 변환에 따른 발열부품의 급격한 발열 현상을 확인하여 해석 모델을 보정하였다. 모델 보정 후 방열구조가 개선된 형상으로 설계를 개선하였으며, 미 군사규격인 MIL-STD-810G 의 고온동작 시험을 수행하여 개선된 형상의 타당성을 검증하였다.

사향의 크로마토그램 패턴 분석을 통한 품질비교 연구 (Quality comparison of musk products using a chromatographic pattern analysis)

  • 조종운;가오단;강종성;정효원;박용기
    • 대한본초학회지
    • /
    • 제36권4호
    • /
    • pp.41-50
    • /
    • 2021
  • Objectives : This study is to check the quality of Moschus products in Korean markets using a chromatographic analysis. Methods : We collected musk products, two genuine products from Russia (A, B), two authentic products from Hong Kong (C) and Korea (D), the Ministry of Food and Drug Safety (MFDS) standard (E), and two fire ants products (E, F). Results : For identification, TLC analysis of 60% ethanol extracts of each product showed that A, B, C, and E have the suitable patterns before color development at 365 nm UV light for the MFDS regulation in Korea. A clear red spot was observed from the E at Rf 0.6 with 365 nm UV light after color development, but this spot was not found in A and B. For the purity test, a distinct violet spot with Rf 0.87 was observed from the A and B in TLC analysis of methanol extracts of each product at white light, however, this spot was not matched with the impurities of E and F. In HPLC-UV pattern analysis, a similar peak pattern was shown in A, B and E, and similar peaks were observed C, although the similarity was weaker than that of A, B, and E. The F and G showed different peak patterns compared with the peak patterns of other samples. Conclusions : Hence, it is considered that the test methods need flexibility in application for identification and purity test depending on the type of sample.

가스 누출 실험, CFD 및 거리산출 비교를 통한 LP가스 누출 검지농도 분포에 대한 고찰 (A Comparison on Detected Concentrations of LPG Leakage Distribution through Actual Gas Release, CFD (FLACS) and Calculation of Hazardous Areas)

  • 김정환;이민경
    • 공업화학
    • /
    • 제32권1호
    • /
    • pp.102-109
    • /
    • 2021
  • Recently, an interest in risk calculation methods has been increasing in Korea due to the establishment of classification code for explosive hazardous area on gas facility (KGS CODE GC101), which is based on the international standard of classification of areas - explosive gas atmospheres (IEC 60079-10-1). However, experiments to check for leaks of combustible or toxic gases are very difficult. These experiments can lead to fire, explosion, and toxic poisoning. Therefore, even if someone tries to provide a laboratory for this experiment, it is difficult to install a gas leakage equipment. In this study we find out differences among actual experiments, CFD by using FLACS and calculation based on classification code for explosive hazardous area on gas facility (KGS CODE GC101) by comparing to each other. We develpoed KGS HAC (hazardous area classification) program which based on KGS GC101 for convenience and popularization. As a result, actual gas leak, CFD and KGS HAC are showing slightly different results. The results of dispersion of 1.8 to 2.7 m were shown in the actual experiment, and the CFD and KGS HAC showed a linear increase of about 0.4 to 1 m depending on the increase in a flow rate. In the actual experiment, the application of 3/8" tubes and orifice to take into account the momentum drop resulted in an increase in the hazardous distance of about 1.95 m. Comparing three methods was able to identify similarities between real and CFD, and also similarities and limitations of CFD and KGS HAC. We hope these results will provide a good basis for future experiments and risk calculations.

구급상황관리사에 의한 심폐소생술 안내 실태 연구 (A study on the cardiopulmonary resuscitation by the emergency medical dispatcher)

  • 김창성;피혜영;이슬기;이현범
    • 한국응급구조학회지
    • /
    • 제25권1호
    • /
    • pp.223-234
    • /
    • 2021
  • Purpose: The purpose of the study is to check up the status of 119 emergency control centers usage. Therefore, the status of use of 119 emergency control centers and the incidence of pre-hospital cardiac arrest patients were investigated. Methods: The emergency activity daily reports and first aid diaries of 119 emergency control centers from January to December 2018 were reviewed. For more accurate status analysis, Among the first aid guidance received in the emergency rescue standard system, the cardiopulmonary resuscitation guide log was reviewed. Results: In 2018, the total usage of the 119 emergency control centers was 1,358,356 calls, hospital guidance werethe most commom (n=629,676, 46.4%), followed by first aid (n=428,027, 31.5%), disease consultation (n=170,238, 12.5%), medical oversight (n=111,188, 8.2%), and interhospital transfer (n=5,052, 0.4%). Regarding the user number per 1,000 persons, Jeju was the greatest at 48.0, whereas Changwon was the lowest at 13.0. A total number of dispatcher-assisted cardiopulmonary resuscitation was 12.181. The time from report to chest compression were 156.2±80.8 seconds for those with previous cardiopulmonary resuscitation training and 168.0±79.3 seconds for those without such training (p<.05). Conclusion: The ratio of first aid instructions, including dispatcher-assisted cardiopulmonary resuscitation, among total usage of the 119 emergency control centers increased. Therefore, additional efforts are required to improve the quality and expertise of information provided through the 119 emergency control centers.