• Title/Summary/Keyword: standard addition method

Search Result 1,440, Processing Time 0.026 seconds

Development of Wireless Earphone Playback Time Measurement Method and Report Form (무선이어폰 재생 시간 측정 방법 및 보고 양식 개발)

  • Han, Mun-Hwan;Jeong, In-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_2
    • /
    • pp.299-307
    • /
    • 2022
  • Wireless earphones, along with smart devices, are the most sought-after products by consumers. Compared to general earphones, wireless earphones do not have twisted wires and are easy to use, so various types of products are currently on the market. However, information on quality is somewhat lacking, so consumers tend to purchase products according to brand awareness, and manufacturers are delivering information to consumers using different standards for each product because there is no standard for quality control. In particular, the playback time of wireless earphones is a factor that directly affects consumers' purchases, so a standard measurement method is needed to properly measure it. In this paper, we present a method for measuring the audio playback time of wireless earphones derived from domestic wireless earphone status survey, commercial product measurement test, and research analysis, and a developed standard measurement method. In addition, this paper proposes a measurement result reporting format to provide accurate information to consumers and induce a fair competitive environment for each product to manufacturers.

Reliability assessment standard development of pneumatic valves (공압 전자밸브 신뢰성 평가기준 개발)

  • 강보식;성백주;김도식;조정대;김형의
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.105-111
    • /
    • 2001
  • In this study, for improvement of pneumatic valve reliability, we grasped the falling-off problem in efficiency of domestic valve and performed detailed analysis the relating International standards, and we also decided sampling method and reliability evaluation items to be evaluated valves. And, in addition, we describe the developed evaluation standard to increase the competition power and to improve the reliability of domestic pneumatic valve manufacturers through deciding of test conditions and thesis of evaluation procedures to each evaluation items.

  • PDF

HIERARCHICAL ERROR ESTIMATORS FOR LOWEST-ORDER MIXED FINITE ELEMENT METHODS

  • Kim, Kwang-Yeon
    • Korean Journal of Mathematics
    • /
    • v.22 no.3
    • /
    • pp.429-441
    • /
    • 2014
  • In this work we study two a posteriori error estimators of hierarchical type for lowest-order mixed finite element methods. One estimator is computed by solving a global defect problem based on the splitting of the lowest-order Brezzi-Douglas-Marini space, and the other estimator is locally computable by applying the standard localization to the first estimator. We establish the reliability and efficiency of both estimators by comparing them with the standard residual estimator. In addition, it is shown that the error estimator based on the global defect problem is asymptotically exact under suitable conditions.

Analytical method to estimate cross-section stress profiles for reactor vessel nozzle corners under internal pressure

  • Oh, Changsik;Lee, Sangmin;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.401-413
    • /
    • 2022
  • This paper provides a simple method by which to estimate the cross-section stress profiles for nozzles designed according to ASME Code Section III. Further, this method validates the effectiveness of earlier work performed by the authors on standard nozzles. The method requires only the geometric information of the pressure vessel and the attached nozzle. A PWR direct vessel injection nozzle, a PWR outlet nozzle, a PWR inlet nozzle and a BWR recirculation outlet nozzle are selected based on their corresponding specific designs, e.g., a varying nozzle radius, a varying nozzle thickness and an outlet nozzle boss. A cross-section stress profile comparison shows that the estimates are in good agreement with the finite element analysis results. Differences in stress intensity factors calculated in accordance with ASME BPVC Section XI Appendix G are discussed. In addition, a change in the dimensions of an alternate nozzle design relative to the standard values is discussed, focusing on the stress concentration factors of the nozzle inside corner.

Practical Silicon-Surface-Protection Method using Metal Layer

  • Yi, Kyungsuk;Park, Minsu;Kim, Seungjoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.470-480
    • /
    • 2016
  • The reversal of a silicon chip to find out its security structure is common and possible at the present time. Thanks to reversing, it is possible to use a probing attack to obtain useful information such as personal information or a cryptographic key. For this reason, security-related blocks such as DES (Data Encryption Standard), AES (Advanced Encryption Standard), and RSA (Rivest Shamir Adleman) engines should be located in the lower layer of the chip to guard against a probing attack; in this regard, the addition of a silicon-surface-protection layer onto the chip surface is a crucial protective measure. But, for manufacturers, the implementation of an additional silicon layer is burdensome, because the addition of just one layer to a chip significantly increases the overall production cost; furthermore, the chip size is increased due to the bulk of the secure logic part and routing area of the silicon protection layer. To resolve this issue, this paper proposes a practical silicon-surface-protection method using a metal layer that increases the security level of the chip while minimizing its size and cost. The proposed method uses a shift register for the alternation and variation of the metal-layer data, and the inter-connection area is removed to minimize the size and cost of the chip in a more extensive manner than related methods.

Determination of Recombinant Human Epidermal Growth factor (rhEGF) in a Pharmaceutical Preparation by Capillary Electrophoresis

  • Hwang, Kyung-Hwa;Lee, Kang-Woo;Kim, Chang-Soo;Han, Kun;Chung, Youn-Bok;Moon, Dong-Cheul
    • Archives of Pharmacal Research
    • /
    • v.24 no.6
    • /
    • pp.601-606
    • /
    • 2001
  • A simple assay method of recombinant human epidermal growth factor (rhEGF) in a pharmaceutical preparation was studied and validated by capillary electrophoresis (CE) using micellar electrokinetic chromatography (MEKC) techniques. Factors affecting the migration behavior and separation performances of the peptide; type of buffers pH, butler concentration, and concentration of sodium dodecyl sulfates (SDS) were investigated to optimize the analytical performance. CE was performed using running buffers 50.0 mM borate (pH 8.5) containing 12.5 mM SDS at 20 $mutextrm{V}$ of the applied voltage. Calibration curves for the rhEGF showed good linearity (r>0.999) over the wide dynamic range from 1.25 to $100{\mu\textrm{g}}/ml$. Sample analysis was performed by using standard addition method to eliminate the matrix effects of dosage vehicle. This method is assumed to be useful for quality control (QC) of various forms of pharmaceutical products of the peptide.

  • PDF

X-Ray Spectrometric Analysis of $Ta_2O_5$,$Nb_2O_5$ and $SnO_2$in Tin Slags using Standard Addition and Dilution Method (표준물첨가 및 희석법을 이용한 주석 슬랙중$Ta_2O_5$,$Nb_2O_5$$SnO_2$의 X-선 분광분석)

  • Young-Sang Kim;Dong-Hui Lee
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.424-482
    • /
    • 1983
  • Determination for $Ta_2O_5$,$Nb_2O_5$ and $SnO_2$ in tin slags was investigated by X-ray spectrometric method. Standard addition-dilution method was attempted and showed a comparable accuracy with standard calibration curve method. Pure chemicals($Ta_2O_5$,$Nb_2O_5$ and $SnO_2$) were added to the samples and diluted with silica or ferric oxide. For the determination of $Ta_2O_5$and$SnO_2$ , silica was more suitable than ferric oxide while the latter was more preferable than the former for $Nb_2O_5$.

  • PDF

A Study on Measurement Method of Audio Playback Time for Standardization of Wireless Earphone Quality (무선이어폰 품질 표준화를 위한 오디오 재생 시간 측정법에 관한 연구)

  • HAN, Munhwan;Jeong, Inho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.141-151
    • /
    • 2022
  • Wireless earphones are products that are consumed together with smart devices (mobile phones, etc), and there is no twisting and convenience compared to general earphones. However, due to the lack of information on the quality of wireless earphones, consumers tend to purchase products based on brand awareness, and manufacturers deliver information to consumers based on different standards for each product due to the lack of standards for measurement methods for quality evaluation. In particular, the playback time of wireless earphones is a factor that can directly affect consumers' purchases, so it is necessary to prepare a standardized test method to properly measure it. This paper introduces the current status of wireless earphones and related standard trends, and proposes a method for measuring the audio playback time of wireless earphones developed through this. In addition, this measurement method will be proposed as an international standard (IEC) after being established as the national standard, the Korean Industrial Standard (KS).

A Robust Watermarking Method against Partial Damage and Geometric Attack (부분 손상과 기하학적 공격에 강인한 워터마킹 방법)

  • Kim, Hak-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.9
    • /
    • pp.1102-1111
    • /
    • 2012
  • In this paper, we propose a robust watermarking method against geometric attack even though the watermarked image is partially damaged. This method consists of standard image normalization which transforms any image into a predefined standard image and embedding watermark in DCT domain of standard normalized image using spread spectrum technique. The proposed standard image normalization method has an improvement over existing image normalization method, so it is robust to partial damage and geometric attack. The watermark embedding method using spread spectrum technique also has a robustness to image losses such as blurring, sharpening and compressions. In addition, the proposed watermarking method does not need an original image to detect watermark, so it is useful to public watermarking applications. Several experimental results show that the proposed watermarking method is robust to partial damage and various attacks including geometric deformation.

Establishment of HPLC-UV Analysis Method Validation for Simultaneous Analysis of Standard Compounds of Oplopanax elatus Nakai Stem (HPLC-UV를 이용한 땃두릅나무 줄기의 지표 성분 동시 분석법 확립)

  • Yoo, Nam Ho;Kwon, Yongsoo;Kim, Myong Jo
    • Korean Journal of Pharmacognosy
    • /
    • v.50 no.2
    • /
    • pp.133-140
    • /
    • 2019
  • In our previous study, we found uracil, adenosine, protocatechuic acid, syringin (eleutheroside B) and scoparone (6, 7-dimethoxycoumarin) in the Oplopanax elatus Nakai Stem. High-performance liquid chromatography (HPLC) -UV was used to quality and quantify the internal marker compounds in the O. elatus extract after validation of method with linearity, limit of detection (LOD), limit of quantitation (LOQ), accuracy and precision. The specificity assessment visually confirmed that the substance was detected without the introduction of other substances. The established method showed high linearity of the calibration curve and coefficient of correlation ($R^2$) of over the 0.999. HPLC was reported as five standard compounds equivalent using the following linear equation based on the calibration curve. The accuracy of measurement was 84.34 ~ 119.74% and the relative standard deviation (RSD) value was 0.28 ~ 1.60%. In addition, our established method showed high repeatability. The RSD value was 1.10 ~ 6.81%. So, we found the amount of the internal marker compounds in the O. elatus extract. These results demonstrated that can be used to quality evaluation of the O. elatus.