• 제목/요약/키워드: stand characteristics

검색결과 543건 처리시간 0.023초

경기장 구조물의 효율적인 진동해석 (Efficient Vibration Analysis of Stadium Structure)

  • 김기철;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.475-482
    • /
    • 2001
  • Stadium stand could be led to significant dynamic response due to rhythmical activities of spectator. The dynamic loads induced by spectators movements are considered as static loads in design standard of many countries but these loads have dynamic characteristics. So, it is desirable to apply measured dynamic loads created by spectator activities and to analyze the dynamic behavior of stadium system. The precise investigation of the dynamic loads on stadium structures and the accurate analysis of dynamic behavior of stadium systems are demanded for effective design. As the floor mesh of stadium stand is refined, the number of nodes increase in numerical analysis. So it is difficult to analyze entire stadium structures and much more computer memory are necessary for vibration analysis of stadium system. In this study, the various dynamic loads induced by spectator movements are measured and analyzed. And new modeling method that reduce the nodal points of stadium systems are introduced. Vibration analysis of stadium system is executed to inspect the accuracy and the efficiency of proposed method in this paper.

  • PDF

진동모니터링을 위한 자가진동발전기의 개발 (Development of Vibration Powered Generator for Vibration Monitoring)

  • 김재민;최남섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.434-441
    • /
    • 2003
  • This paper presents a generator for stand-alone vibration monitoring system of bridge structure based on ambient vibration of bridge. In this paper, a novel electric power generator which has minimum effect of armature reaction is proposed. The related mechanical and electrical design equations are obtained and a pilot generator has been implemented. In addition, the charging system for extremely low generator current is discussed, and some improvements are identified for the system. This investigation reveals that diode characteristics of rectifier is dominant factor in the charging process. Finally, both the simulation, which uses real measurement data of the Namhae bridge as input of the pilot generator, and indoor test are carried out. The results showed the applicability and effectiveness of the stand-alone vibration powered generator.

  • PDF

Large Cryosorption Pump for the NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제7권2호
    • /
    • pp.27-32
    • /
    • 2003
  • A large cryo-pumping system composed of 4 cryosorption pumps was designed and manufactured to satisfy the pressure requirements of the NBI test stand. The cryosorption pump consists of a thermal shield/baffle assembly and a cryopanel coated with activated carbon granules. The thermal shield is cooled by liquid nitrogen, and the cryopanel by a commercial helium refrigerator. The operation characteristics and vacuum performance of the cryosorption pump were investigated. The cooling down time of the cryopanel to 20 K was about 6 hours with a liquid nitrogen consumption rate of about 35 L/hr. The maximum pumping speed of the cryosorption pump for the hydrogen gas measured by the steady pressure method was about 90,000 L/s.

  • PDF

최소 컷셋법에 의한 화력발전소 기동전원의 신뢰도 예측에 관한 연구 (A Study on the Reliability Evaluation of Start-up Power Supply in Fossil Power Plant by Minimal Cut-Set Method)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.358-364
    • /
    • 1999
  • The auxiliary transformers or start-up/stand-by transformer(s) are installed against the start-up and shut-down of generator and emergency status in fossil power plant. The on-site power supply configuration using these transformers must be determined, considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and ecfonomy of plant. The auxiliary or start-up/stand-by power supply configuration has been determined considering only safety requirements and construction cost until now in Korea. This paper presents general theorems for the reliability estimation and proposes 2-unit based 4 alternatives for the start-up power supply stystem of 500㎿ standardized fossil power plant. The reliability and unavailability of equipment, system and configuration are determined using minimal cut-set methodology. The optimized plan of 4 alternatives is determined based on this ultimate reliability and unavailability.

  • PDF

FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구 (A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod)

  • 최규식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권5호
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

1kW소형 풍력발전기의 진동 모니터링 (Vibration Monitoring of a 1kW Small Wind Turbine Generator)

  • 김석현;남윤수;유능수;김윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.308-311
    • /
    • 2006
  • A vibration monitoring is performed on a 1kW class stand alone wind turbine(W/T). When a W/T model is developed, general performance under various wind condition should be verified to introduce the product in the market. Especially, vibration characteristics within operating speed range are very important in the aspect of structural stability as well as generator's electrical efficiency. This paper examines the vibration performance of a home made 1kW W/T Various data of the W/T model are acquired in real time using a remote vibration monitoring system installed in Daekwanryung test site. Vibration stability of the W/T structure is diagnosed based upon the data and the result is used to estimate the applicability of the W/T model.

  • PDF

LED를 이용한 감성조명디자인 개발 연구 - 토요 이토 건축의 관계성 개념을 중심으로 - (Study on the Development of Sensitivity Lighting Design Using LED - Focused on the Concept of Relationship in Toyo Ito's Architecture -)

  • 김종서
    • 한국가구학회지
    • /
    • 제28권4호
    • /
    • pp.332-339
    • /
    • 2017
  • Today, our indoor space requires a user-centered considering design that satisfies even human sensitivity. The word 'sensitivity' is being frequently used in the design market recently and this means that consumers are becoming more sensitive. For this reason, the characteristics of Toyo Ito's architecture, which are innocent due to its natural structure and materials, are suggested as a sensitive lighting stand design which can relieve users' stress from daily life and bring a psychological stability. As such, sensitivity lighting can create a lighting environment that considers consumers in various spaces along with the development of new scientific technologies and develop in a new direction of aesthetical beauty and eco-friendly area. In this study, a natural and sensitive lighting stand is suggested where a variety of digital art techniques of LED are applied based on formative characteristics of relationship, one of Toyo Ito's architectural concept factors. Such sensitivity lighting designs can not only realize a type-free design but also suggest a creation of the atmosphere which is close to nature.

칼라눕힘분에 따른 칼라 및 라펠의 특성 연구 -테일러드 칼라 재킷을 중심으로- (A Study on the Character of Collar and Lapels According to Collar Laying Amount -Focused on Tailored Jacket-)

  • 이소영
    • 한국의류학회지
    • /
    • 제35권4호
    • /
    • pp.421-430
    • /
    • 2011
  • This study suggests the proper collar laying amount to be actively used in the clothing industry by identifying the characteristics of collar and other related components according to the collar laying amount. This study comparatively analyzed the characteristics of each collar laying amount (2cm, 2.5cm, 3cm, 3.5cm, 4cm, and 4.5cm) after making 6 tailored jackets. The results are as follows: 1. The best shape of collar and lapel appeared when the collar laying amount was 3cm and 3.5cm. 2. Depending on the collar laying amount, the shape of collar, roll line form of collar and lapel, collar width, collar stand, the position and width of roll line changed. As the collar laying amount increased, the length of collar edge became longer, and the collar stand decreased. In case the collar laying amount was small (2cm, 2.5cm), the width of collar and lapel became narrower. On the contrary, when it is large (4cm, 4.5cm), the width of collar and lapel became wider. 3. Collar laying amount as well as the length of the neck line of collar affected the shape of the collar roll line around the neck.

쿨링용 슬레트 핀 M/C Form Roll의 Roll Stand부 마찰 특성 (The Friction Characteristics of Roll Stand in the Cooling Slat Fin M/C)

  • 최원식;이성용;권주리;진은영;문희준;이인
    • Tribology and Lubricants
    • /
    • 제26권1호
    • /
    • pp.52-55
    • /
    • 2010
  • This study investigates the friction of the roll stands in the high performance multi- holes slate fin machine which pin is using in heat transfer of radiator, oil cooler, inter cooler, condenser and evaporator. The roll stand part is very important to maintain the high performance fin machine. This multi-holes form roll type is the first time in our country so it will be helpful to increases the export and product of heat transfer. It was include the technical of form rolling system which was self development. Then it will be improve the electric home appliances, future motor vehicle device and industrial machine.

재진입 비행체 외부 열유동장의 고온반응기체 효과에 관한 전산해석 (COMPUTATIONAL INVESTIGATION OF THE HIGH TEMPERATURE REACTING GAS EFFECTS ON RE-ENTRY VEHICLE FLOWFIELDS)

  • 강은지;김준영;박재현;명노신
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.7-14
    • /
    • 2014
  • Aerothermodynamic characteristics of re-entry vehicles in hypersonic speed regimes are investigated by applying CFD methods based on the Navier-Stokes-Fourier equations. A special emphasis is placed on the effects of high temperature chemically reacting gases on shock stand-off distance and thermal characteristics of the flowfields. A ten species model is used for describing the kinetic mechanism for high temperature air. In particular, the hypersonic flows around a cylinder are computed with and without chemically reacting effects. It is shown that, when the chemically reacting effects are taken into account, the shock stand-off distance and temperature are significantly reduced.