• Title/Summary/Keyword: stainless steel wastewater

Search Result 30, Processing Time 0.024 seconds

Improvement of Drainage Material for Attached Algae Growth Control in Sedimentation Basin (부착성장 조류 제어를 위한 침전지 배수로의 재질개선에 관한 연구)

  • Jun, Dae-Young;Lim, Byung-Ran;Yu, Hyun-Sun;Cho, Jin-Woo;Hwang, Jong-Hyuk;Ahn, Kyu-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.193-199
    • /
    • 2005
  • The objective of this study was to investigate the characteristics of adhesion and detachment of algae on various materials of drainage canal in the sedimentation basin. The influence of surface washability, surface roughness, phosphorous concentration was studied using stainless steel, cement block and ceramic panel. The algae attached content of cement block was higher than that of the ceramic coating panel. The attachment varied significantly with respect to exposure time and different materials. the attachment was higher on rough surface (cement block) when compared to smooth surfaces. The content of attached algae increased with increasing phosphorous concentration in water. The detachment efficient of algae was higher on ceramic panel.

Effects of Current Density and Electrolyte on COD Removal Efficiency in Dyeing Wastewater Treatment by using Electro-coagulation (전기 응집법을 이용한 염색 폐수의 처리에서 전류 밀도와 전해질의 COD 제거율에 대한 영향)

  • Jang, Seong-Ho;Kim, Go-Eun;Kang, Jeong-Hee;Ryu, Jae-Yong;Lee, Won-ki;Lee, Jae-Yong;Park, Jin-Sick
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.7
    • /
    • pp.653-659
    • /
    • 2018
  • In the industrial wastewater that occupies a large proportion of river pollution, the wastewater generated in textile, leather, and plating industries is hardly decomposable. Though dyeing wastewater has generally been treated using chemical and biological methods, its characteristics cause treatment efficiencies such as chemical oxygen demand (COD) and suspended solids (SS) to be reduced only in the activated sludge method. Currently, advanced oxidation technology for the treatment of dyeing wastewater is being developed worldwide. Electro-coagulation is highly adapted to industrial wastewater treatment because it has a high removal efficiency and a short processing time regardless of the biodegradable nature of the contaminant. In this study, the effects of the current density and the electrolyte condition on the COD removal efficiency in dyeing wastewater treatment by using electro-coagulation were tested with an aluminum anode and a stainless steel cathode. The results are as follows: (1) When the current density was adjusted to $20A/m^2$, $40A/m^2$, and $60A/m^2$ under the condition without electrolyte, the COD removal efficiency at 60 min was 62.3%, 72.3%, and 81.0%, respectively. (2) The removal efficiency with NaCl addition was 7.9% higher on average than that with non-addition at all current densities. (3) The removal efficiency with $Na_2SO_4$ addition was 4.7% higher on average than that with non-addition at all current densities.

Current Generation from Microbial Fuel Cell Using Stainless Steel Wire as Anode Electrode (스텐철사를 전극으로 이용하는 미생물연료전지의 전류 발생)

  • Jang, Jae Kyung;Kim, Kyung Min;Byun, SungAh;Ryou, Young Sun;Chang, In Seop;Kang, Young Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.753-757
    • /
    • 2014
  • Anode electrode in a microbial fuel cell (MFC) should transfer the receiving electron as well as provide large surface area that can be immobilized microorganisms. Microorganisms' population is one of important factors to improve the current generation and to treat the livestock wastewater by biological treatment. These studies were attempted to investigate if stainless-steel wire skein (SSWS) could be used as anode electrode replacement a graphite felt electrode in microbial fuel cell. For these studies, pretreated livestock wastewater was used diluted to 500 mg/L as COD before use. At this time, the current showed a little difference of about 5% when using each of a SSW and graphite felt (control). There was no significant difference in the current value. The organic removal rate in the microbial fuel cells used graphite felt and SSWS was 82.4% and 88.3%, respectively. The COD removal in the MFC used the SSWS was higher than that of graphite felt. Ammonium nitrogen was showed similar trend in two case all. These results about current generation and organic matter reduction seem possible that SSWS was used to anode electrode. When SSWS is used, the initial investment for system construction is expected to be able to reduce by approximately 1/50.

Studies on a Feasibility of Swine Farm Wastewater Treatment using Microbial Fuel Cell (미생물연료전지의 가축분뇨 처리 가능성 연구)

  • Jang, Jae-Kyung;Kim, Se-Hee;Ryou, Young-Sun;Lee, Sung-Hyoun;Kim, Jong-Gu;Kang, Young-Goo;Kim, Young-Hwa;Choi, Jung-Eun
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.461-466
    • /
    • 2010
  • In this study the feasibility of simultaneous electricity generation and treatment of swine farm wastewater using microbial fuel cells (MFCs) was examined. Two single-chamber MFCs containing an anode filled with different ratio of graphite felt and stainless-steel cross strip was used in all tests. The proportion of stainless-steel cross strip to graphite felt in the anode of control microbial fuel cell (CMFC) was higher than that of swine microbial fuel cell (SMFC) to reduce construction costs. SMFCs produced a stable current of 18 mA by swine wastewater with chemical oxygen demand (COD) of $3.167{\pm}80\;mg/L$ after enriched. The maximum power density and current density of SMFCs were $680\;mW/m^3$ and $3,770\;mA/m^3$, respectively. In the CMFC, power density and current density was lower than that of SMFC. CODs decreased by the SMFC and CMFC from $3.167{\pm}80$ to $865{\pm}21$ and $930{\pm}14\;mg/L$, achieving 72.7% and 70.6% COD removal, respectively. The suspended solid (SS) of both fuel cells was also reduced over 99% ($4,533{\pm}67$ to $24.0{\pm}6.0\;mg/L$). The concentration of nutritive salts, ${NH_4}^+$, ${NO_3}^-$, and ${PO_4}^{3-}$, dropped by 65.4%, 57.5%, and 73.7% by the SMFC, respectively. These results were similar with those of CMFC. These results show that the microbial fuel cells using electrode with mix stainless-steel cross strip and graphite felt can treat the swine wastewater simultaneously with an electricity generation from swine wastewater.

The Study of Advanced Treatment of Sewage Wastewater by the Electro Coagulation and Oxidation System (전기응집산화를 이용한 하수처리장의 고도처리방안 연구)

  • Lim, Jin-Hwan
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.556-562
    • /
    • 2018
  • Due to the enforcement of effluent water regulation the advance sewage treatment system is needed to retrofit and remodelling. In this case the most important issue is the effluent concentrations of TP and there are a lot of system to reduce its concentration. But biological treatment processes have many restrictions to enhance the removal efficiency of TP. In this study the efficient ECO operating condition to improve and retrofit biological sewage wastewater treatment system is as follow; 1) The treatment efficiency of BOD, TN and TP at the current density of $15mA/cm^2$ was higher than the treatment efficiency at $5mA/cm^2$ in the electrodes arranged with Al-SUS(Stainless Steel) regardless of the reaction time, The TP concentration was 0.1 mg/L or less. Especially, when the reaction time was maintained at 10 min, the TP concentration was 0.06 mg/L or less irrespective of the current density. 2) The change of TP concentration is not influenced by the change of current density and rather the concentration of treated water changes according to the reaction time. In the case of electro coagulation reaction, a few seconds to several minutes are required. However, the reaction time of electro coagulation and oxidation was studied to be more than 10 minutes. 3) As a result, it has been studied that the economical current density of the electro coagulation oxidation process for TN and TP treatment of domestic wastewater is $15mA/cm^2$ or less and the reaction time is 10 minutes.

Nitrogen Removal by Electrochemical Oxidation Using the Tube Type Electrode (튜브형 전극을 이용한 전기화학적 산화에 의한 질소제거에 관한 연구)

  • Cho, Jae-Jun;Jeong, Jong-Sik;Lee, Jae-Bok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.580-587
    • /
    • 2004
  • The objective of this research is to investigate the electrochemical oxidation process for nitrogen removal in wastewater involving chloride ion and nitrogen compounds. The process experiment of electrochemical oxidation was conducted by using the stainless steel tube type reactor and the $Ti/IrO_2$ as anode. Free chlorine production and current efficiency variation for total nitrogen removal was compared depending on whether electrolyte is added, and the nitrogen type distribution under an operating condition. When chloride was added as electrolyte, it was found that production of free chlorine increased and the concentration of the chloride decreased as retention time passed. The concentration of chloride in influent decreased from 1,660 to 1,198 mg/L at the current density of $6.7A/dm^2$, while concentration of free chlorine increased to 132 mg/L. Current efficiency in removal of ammonium nitrogen was increased when chloride was dosed as electrolyte. It was observed that ammonium nitrogen was oxidized to nitrite and nitrate through electrochemical oxidation and that the concentration of total nitrogen in influent was reduced from 22.58 to 4.00 mg/L at the short retention time of 168 seconds through the electrochemical oxidation of nitrogen.

A Study on the Corrosion Characteristics Evaluation for Reactor Material of Waste Water Treatment (폐수처리 반응기용 재질의 부식특성 평가에 대한 연구)

  • Kim, Ki-Tae;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.2
    • /
    • pp.60-65
    • /
    • 2008
  • As the operating conditions in a supercritical oxidation reactor are set in high temperature with high pressure causing a reactor suffering from the harsh circumstances. It means the reactor adopts itself with Fe-Cr alloy in acidic atmosphere with low pH value and Ni alloy in basic atmosphere with high pH value due to its superior corrosion resistance. The study, whose target waster water is pertinent to the latter part, has selected Ni alloy such as ostenite type stainless steel 304 and 316, superstainless steel AL6XN, Inconel 625, MAT 21, and titanium Gr. 5 in order to measure corrosion resistance against those samples under the same conditions of temperature and pressure applied for a supercritical oxidation reactor. The result shows the identifiable difference in corrosion resistance by observing the surface states through a scanning probe microscope as well as measuring the weight loss through making the samples above deposited in wastewater for two-week and four-week stay. The purpose of this corrosion experiment is to identify the most corrosion-resistant material among sample species pre-selected according to pH concentration of wastewater in pursue of applying for a reactor exposed to the extreme corrosion environment. It is because such a reactor made of a verified material enables to safeguard a stable operation under the supercritical wastewater processing facility.

  • PDF

Fluoride and nitrate removal in small water treatment plants using electro-coagulation (전기응집을 이용한 소규모 수도시설의 질산성질소와 불소이온 제거)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.767-775
    • /
    • 2011
  • In this study we verified if the electro-coagulation process can treat properly the nitrate and fluoride that are not removed well in the conventional small water treatment plants which usually employ chlorination and filtration only. As we gave a change of electrode material and gap-distance between electrodes, removal efficiency of the nitrate and fluoride was determined by electro-coagulation process which were equipped with aluminum and stainless steel (SUS304) electrodes. In addition, electrode durability was investigated by determination of electrodes mass change during the repetitive experiments. Removal efficiency was great when aluminum was used as an anode material. Nitrate removals increased as electric density and number of electrodes increased, but fluoride removal was less sensitive to both parameters than nitrate. After 10 minutes of contact time with the current density from $1{\times}10^{-3}$ to $3{\times}10^{-3}A/cm^{2}$, nitrate and fluoride concentration ranged from 9.2 to 1.2mg/L and from 0.02 to 0.01mg/L, which satisfied the regulation limits. Regardless of the repeating number of experiments, removal efficiency of both ions were almost similar and the change of electrode mass ranged within ${\pm}$0.5%, indicating that the loss of the electrode mass is not so much great under the limited circumstances.

The Investigation of Treatment of Pistachio Processing Industrial Wastewater by Electrochemical Methods in Terms of Chemical Oxygen Demand and Total Phenol Removal

  • Alper Erdem Yilmaz;Baybars Ali Fil;Murat Tolga Yilmaz;Serkan Bayar;Zuhal Koksal
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.178-189
    • /
    • 2024
  • This work aims to investigate the efficiency of electrocoagulation (EC) of pistachio processing industrial wastewater (PPIW) using the continuous EC process. The tubular reactor made of stainless steel with an internal diameter of 60 mm was used as a cathode electrode. The effect of some parameters was examined on the removal of chemical oxygen demand (COD) and total phenols (TP) removal efficiency. The influences of the initial pH of wastewater (from 4 to 8), flow rate (from 25 to 125 mL/min), current density (from 7 to 21 mA/cm2), and supporting electrolyte type (NaCl, NaNO3, and Na2SO4), supporting electrolyte concentration (from 10 to 100 mg/L NaCl) on removal efficiency were investigated to determine the best experimental conditions. The examination of the physico-chemical parameters during the EC treatment showed that the best removal efficiency was obtained under conditions where the flow rate was 25 mL/min (20 min reaction time), the pH value was 5.2, and the current density was 21 mA/cm2 has set. Under these experimental conditions, COD and TP removal efficiency were found to be 75% and 97%, respectively, while energy consumption was 18.5 kW h/m3. The study results show that the EC can be applied to PPIW pre-treatment.

Electrochemical Destruction of Cyanide Ions and Recovery of Zinc Ions from Electroplating Wastewater (도금폐수 중의 시안착이온의 전기화학적 분해 및 아연 회수에 관한 연구)

  • Niu, Lin;Ro, Byung-Ho;Jung, Cheul;Lee, Yong-Ill
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.699-704
    • /
    • 2000
  • A study has been made for the electrochemical destruction of cyanide ions and removal of zinc ions from a simulated electroplating wastewater by the use of a platinum platized-titanium anode and a stainless steel cathode. Several experimental parameters, including electrolysis time, cell current, additives, and chloride concentration, have been investigated and used for efficient destruction of cyanide waste and removal of zinc ions from aqueous solutions. It was found that cell current and type of additives gave great effects on the destruction of cyanide ions and removal of zinc ions. The optimized conditions (electrolysis time: 1hr, current: 12A, additive: 0.5 M NaCl) have been defined to destroy cyanide ions and remove zinc ions with high efficiency and low operation cost. The proper reaction mechanism leading to the destruction of cyanide on the anode has also been discussed.

  • PDF