• Title/Summary/Keyword: square wave voltage

Search Result 127, Processing Time 0.027 seconds

Digital Control Methods of Two-Stage Electronic Ballast for Metal Halide Lamps with a ZVS-QSW Converter

  • Wang, Yijie;Zhang, Xiangjun;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.451-460
    • /
    • 2010
  • This paper presents a new kind of digital control metal halide lamp electronic ballast. A zero-voltage-switch quasi-square-wave (ZVS-QSW) dual Buck converter is adopted here. In this paper, a digital control method is proposed to achieve ZVS for the converter. This ZVS can be realized during the whole working condition. Single-cycle-peak-current control is proposed to solve the problem of excessive inductor current during a low-frequency reversal transient. Power loop control is also realized and its consistency for different lamps is good. An AVR special microcontroller for a HID ballast is used to raise the control performance, and the low-frequency square-wave control method is adopted to avoid acoustic resonance. A 70W prototype was built in the laboratory. Experimental results show that the electronic ballast works reliably. Furthermore, the efficiency of the ballast can be higher than 92%.

Electro-mechanical Properties of Piezoelectric Ceramic Bimorphs (압전 세라믹 바이모프의 전기기계적 특성)

  • Lee, Yong-Kuk;Lee, Hae-Ryong;Kim, Chang-Kyo;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1416-1418
    • /
    • 1994
  • Expressions for the displacement of a bimorph, one end fixed and the other free, has been introduced when sinusoidal inputs were applied to the ceramic plates on a thin metal plate. Maximum displacements at the free end and strains at the position of strain gage attached were measured when various wave forms, voltages, and frequencies were applied to the bimorph whose length is 6.6[cm], width 2.5[cm], and thickness 0.0365[cm]. Under the constant voltage ( $70[V_{peak}]$ ), the strains and the displacements at the free end were larger than the case of the sinusoidal input when the square wave was applied and were smaller when triangular wave. It was shown that the displacements at the free end and the strains of the gage position were increased as the applied voltage in the range of $30-90[V_{peak}]$ and effective length were increased. And it was also found that the resonant frequency of a bimorph was decreased as its effective length was increased, and that the displacements and the strains were maximum at the resonant frequency.

  • PDF

DYNAMICAL PERFORMANCE OF A NEW TYPE OF THREE PHASE SYNCHRONOUS MOTOR DRIVE SUPPLTED BY SQUARE-WAVE INVERTERS

  • Soltani, Jafar
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.493-497
    • /
    • 1998
  • In this paper, a three phase voltage source inverter synchronous motor drive is introduced which is capable of producing an approximate to sine-wave currents in the stator windings. Compare to a conventional current forced synchronous machine drive, for the same machine loss, a gain in out put per unit overall volume of 125% at a 50Hz supply frequency has been achieved. In addition, the torque pulsation has been drastically reduced. These improvements are achieved by introducing new rotor windings which are capable of controlling the stator current waveforms an approximate to sine-wave. A computer program has been developed which can be used to predict the dynamic performance of this drive/system. The paper describes the design of rotor windings for cylindrical rotor motor but the theory is equally applicable to salient-pole designs.

  • PDF

Luminous efficacy according to operating voltages of high flux RGB LEDs (고출력 RGB 발광다이오드의 구동전압에 따른 발광효율 비교)

  • Song, Sang-Bin;Kwon, Yong-Seok;Im, Sung-Mu;Yeo, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1710-1712
    • /
    • 2003
  • This paper analyzes the effects of various operating voltages on the luminous efficacy of high flux RGB LEDs. At first, their equivalent diode model are established from measurements of the V-I characteristics. Operating voltages of three types are applied to a simple LED circuit: DC, square-wave, and full-wave-rectified sine wave. As the result, DC voltage driving gives the hightest efficiency, but invokes much greater variation in the luminous flux and more shift in the peak wavelength.

  • PDF

Characteristics of high-power RGB LEDs according to types of operating voltage (고출력 발광다이오드의 구동전압 유형에 따른 특성)

  • 임성무;권용석;송상빈;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.169-173
    • /
    • 2003
  • This paper analyzes the effects of various operating voltages on the electrical and light output characteristics of 20mW(5mm-Ф), 1W and 5W high-power RGB LEDs. Operating voltages of three types are compared on a simple LED circuit: DC, full-wave rectified DC. and square-wave DC. As a result, it is found that the 1W and 5W high-power LEDs should be provided with appropriate heat sinks that hold down the increase of junction temperature. As for the operating efficiency the case of full-wave rectification gives the highest value.

  • PDF

Measurement and Analysis of Risk Voltages by Various Current Sources in Grounding System (다양한 전류원에 대한 접지시스템의 위험전압 측정과 분석)

  • Kil, Gyung-Suk;Moon, Byoung-Doo;Kim, Hwang-Kuk;Park, Dae-Won;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.113-118
    • /
    • 2009
  • Grounding systems set the reference voltage level of electric circuits and suppress the Ground Potential Rise (GPR) by flowing fault currents to the ground safely. There are several parameters which evaluate the performance of grounding systems as ground resistance, touch voltage and step voltage. The touch and step voltages, which is called "risk voltage", are especially important to ensure the safety of human body. This paper dealt with the influence of current sources with the different frequency components on the touch and the step voltages. Three types of current sources as commercial frequency, square wave, and surge with the fast risetime of $50\;ns{\sim}500\;ns$ were used to analyze the risk voltages in a grounding system. The risk voltages showed remarkable difference in the same current amplitude depending on the current sources, and increased linearly with the current amplitude in the same current source. From the experimental results, it was confirmed that the risk voltages can be evaluated by a small current application in large-scale grounding systems and the possible largest risk voltage can be calculated by a surge current with the risetime of 200 ns or a current source with the same frequency component as the surge current.

Study on Electronic Ballast for Metal Hallide Lamps (메탈 할라이드 램프용 전자식 안정기에 관한 연구)

  • 오병석;정화진;지철근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.16-21
    • /
    • 1992
  • Incandescent lamps and discharge lamps are generally used as light sources and special ballasts are needed thor stable operation of discharge lamps. In this paper, the author proposes the electronic ballast thor metal hallide lamps, experiments with high frequency square wave of frequency 22.52 KHz to avoid the acoustic resonance phenomenon and proves the usefulness of the proposed ballast. Furthermore, the author uses 220 AC voltage as a input voltage source of the proposed ballast. By examining the proposed ballast, lamp voltage of 139 V(max.) and lamp current of 1.4 A(max) can be measured. Furthermore, stable operation antral great luminouse fluxes are recognized.

  • PDF

Characteristics Analysis of Flux-Reversal Machine considering BEMF Current (역기전력 전류를 고려한 자속 역전식 기기의 특성 해석)

  • Kim Tae Heoung;Lee Ju
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.709-717
    • /
    • 2004
  • Flux-reversal machine (FRM) is a new brushless doubly salient permanent magnet machine. Its operation is similar to that of the brushless DC motor, so it can be driven by 120 degree square wave voltage and use PWM pulse patterns in two-phase feeding scheme to control the speed. In this driving method, the back electromotive force (BEMF) current in the open phase is generated by the BEMF. It can be appeared or disappeared according to the changes of the neutral voltage of the machine. In this paper, the time-stepped voltage source finite-element method taking BEMF current into account is proposed. Its influences on the performances of the FRM are also investigated. To prove the propriety of the proposed analysis method, a Digital Signal Processor (DSP) installed experimental devices are equipped and the experiment is performed.

New Control Strategy for Reducing Switching Losses in Three-Phase Voltage-Source PWM Converters

  • Dong, Xiaopeng;Wang, Zhaoan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.366-373
    • /
    • 1998
  • In this paper, a new control strategy to reduce switching losses in three-phase voltage-source PWM converters is proposed according to Modified-Period-Average-Model (MPAN). The basic concept of this strategy is aimed at calculating the phase control voltages for controlling the source currents to be sinusoidal and in phase with the source voltages, and reducing the number of switching in each period. The phase control voltages of Period-Average-Model(PAM) is obtained according to analyzing the operation of PWM converter. In order to reduce the sensitivity to system parameters in PAM, MPAM is deduced. Then a square wave whose frequency is three times of utility frequency is added to the phase control voltages derived from MPAM. The control strategy reduces the switching losses since there exists about one-third blanking time for every phase in one period. The theoretical derivation and the control strategy are experimentally verified on a 2.5 kW three-phase voltage source converter.

  • PDF

Improved Signal Processing Method for IPMSM Sensorless Technique using Switching Frequency Square-wave Voltage Injection (스위칭 주파수의 구형파 전압 주입을 이용한 IPMSM 센서리스 기법의 개선된 신호처리 기법)

  • Nam, S.H.;Park, N.C.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.15-16
    • /
    • 2012
  • 본 논문에서는 스위칭 주파수의 구형파 전압 주입을 이용한 IPMSM의 센서리스 제어 기법에서 개선된 신호처리 방법을 제안하였다. 제안된 기법에서는 기본파 전류와 고주파 성분 전류추출에 필요한 필터를 간단히 구현함으로써 신호처리에서 발생하는 시지연을 줄일 수 있으며, 그 결과 센서리스 제어의 동특성을 개선할 수 있다. 800[W]급 IPMSM에 대한 실험을 통해 제안된 방법의 타당성을 검증하였다.

  • PDF