• Title/Summary/Keyword: spray line

Search Result 101, Processing Time 0.025 seconds

Parametric Analysis of Digital Particle Holography for Spray Droplets (분무 액적을 위한 디지털 입자 홀로그래피의 파라미터 해석)

  • Yang, Yan;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.191-197
    • /
    • 2007
  • This study presents in-line digital particle holography and its application to spray droplets to measure the characteristics of spray droplets. Several important parameters at the time of hologram recording such as the object distance and the region of laser beam used were verified. The correlation coefficient method with important parameters such as the reconstruction interval and the correlation interval was used for determination of the focal planes of particles. The optimal values of all these parameters are obtained by either numerical simulation of holograms or experiments. Using these optimal parameters, double pulse digital spray holograms in a short time interval were recorded with the synchronization system for the time control. The spatial positions of droplets that are used for the evaluation of the three dimensional droplet velocities can be easily located, which proves the feasibility of the digital holographic technology for measurements of several important features of spray droplets.

  • PDF

Spray Distribution Measurement at High Ambient Pressure (고압 환경 하에서의 분무 분포 측정)

  • Cho, Seong-Ho;Im, Ji-Hyuk;Yoon, Young-Bin;Choi, Seong-Man;Han, Young-Min
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.59-65
    • /
    • 2008
  • Distribution of spray was measured. Optical Line Patternator (OLP) was used to measure the planar distribution of the spray from a swirl-coaxial type injector. Ambient pressure was varied and injection pressure was fixed in experiment. As ambient pressure increased, spray distribution was changed from hallow cone to solid cone shape, and spray angle was decreased. Limitation in measuring dense spray was found at high ambient pressure condition.

Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

Experimental Study on the Flow Characteristic of a Confined Ppray (제한된 공간내 분무의 유동특성 실험)

  • 정선재;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.1011-1018
    • /
    • 1992
  • A series of experiment has been performed on the spray characteristics in a cylindrical confined space with the injection pressure taken as a parameter. By using a single-hole patternator and the Malvern particle sizer, the spray mass flux, drop size and volume concentration distributions along the radial and axial directions were obtained ; the line-of- sight data by Malvern particle sizer have been converted to the ring-of-sight data by using the tomographical transformation techniqe. The experimental results show that, due to the restriction on the ambient gas entrainment by the wall boundary, the effective spray angle is increasing. The spray drops were measured to be smaller in the confined space because of a large number of floating small drops by recirculation of the gas phase and the breakup of large drops by the wall collision. Also the details on the flow behavior of the confined spray are discussed.

Measuring the characteristic of aerial spray by rotary wing (회전익 항공기 공중살포 특성 측정)

  • Lim, Se-Hoon;Song, Byung-Heum
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.17 no.1
    • /
    • pp.46-51
    • /
    • 2009
  • This paper presents results from field studies carried out to monitor off-target droplet movement of endosulfan insecticide applied to the Korea chestnut tree area. As a results, mean airborne drift values were recorded 25m as average from downwind of a single flight line(sample line) in mountain terrain and mean effective swath width was recorded 19.5m as average in a plain. In terms of characteristics of geography of Korea aerial application is mainly carried out in mountain terrain. The equipment, weather conditions, and appropriate aerial spray technic are required for effective aerial application. In particular, the pilot can get effective results when he only sprays with consideration of environment factors since there is much turbulence in mountain terrain. Eventually, the most effective factor of droplets drift is to estimate the local weather conditions exactly.

  • PDF

STUDY ON THE CURVE DEPENDENT WHEEL FLANGE LUBRICATOR WITH CREASE SPRAY TYPE (곡선감지형 그리스 분사식 후렌지 도유기에 관한 연구)

  • 이주호;노양환;양방섭
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.188-192
    • /
    • 2002
  • In this study, Curve dependent wheel flange lubricator with grease spray type is introduced and checked and estimated a point of view reducing wheel flange wear and noise in the curve. Advantage of curve dependent wheel flange lubricators with grease spray type is found on the basis of the result of field test applied to KNR No. 1 Line(reconstruction car).

  • PDF

Comparisons of Diesel and DME Fuel in Macroscopic Spray Characteristics (디젤 및 DME 연료의 거시적 분무특성 비교)

  • Park, Junkyu;Chon, Munsoo;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.205-209
    • /
    • 2012
  • This study focused on comparing macroscopic characteristics of DME and diesel fuel experimentally. DME fuel is one of the most promising alternative fuels because of its superiority in atomization characteristic and clearness in terms of exhaust gas compared with existing fossil fuels. In addition, DME fuel has high cetane number so it could be applied to compression ignition engine. However because DME fuel exists in gas phase at room temperature and atmospheric pressure, and it corrodes rubber parts of fuel line, DME fuel is hard to apply to commercial vehicles. To establish knowledge about DME fuel and furthermore, to develop commercial DME vehicles such as passenger cars, many research have been proceeded steadily. The present study, by comparing spray characteristics of DME fuel to those of diesel fuel, improved atomization characteristics in DME were revealed. Injection quantity measurement and spray visualization experiment were progressed and it was revealed that DME fuel shows small injection quantity than that of diesel fuel and axial development of spray in terms of spray tip penetration decreases when DME fuel was injected.

Analysis of spray cone angle of air assisted flash atomization (공기보조식 (air-assisted) 플래쉬 분무의 분무 각 확대 특성 연구)

  • Yu, Tae-U;Kim, Sae-Won;Bang, Byong-Ryeol
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • When the water jets heated up to the saturation temperature at a high line pressure are sprayed into a reduced (atmospheric) pressure through an air-assisted nozzle, the jets experience sudden exposure into a reduced pressure, get superheated and produce steam bubbles while atomization processes of jets are taking place. This process is called flash atomization. In this study the flash atomization of superheated water jets assisted by air has been studied. Sprays with flash atomization have been photographed at various water and air flow rates and water superheats. It has been found that the spray angle with flash atomization increases with water superheat and water flow rate but decreases with air flow rate. The degree of change of spray angle has been analyzed and correlated as a function of superheat, air and water flow rates.

  • PDF

Mass Distribution and Spray Characteristics to Liquid-Gas Line Selection of Unlike Triplet Impinging Injector (비동질 3중 충돌형 인젝터의 기체-액체 라인 선택에 따른 분무특성)

  • Lee, I.C.;Lee, C.J.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.205-211
    • /
    • 2006
  • Impinging angle, impinging distance, length eve. diameter and injection pressure of a triplet injector were tested to evaluate the spray characteristics injected by liquid/gas combinations. Two different kinds of unlike triplet sprays were produced by changing the gas and liquid feed lines. One was the G-L-G(Gas-Liquid-Gas) type, and the other was L-G-L(Liquid-Gas-Liquid) type. Spray angles were wider with the G-L-G type than with L-G-L type. Mass distributions in spray were obtained with a, mechanical patternator. Mass distributions were not circular but elliptical distributions. When the range of mechanical patternator to injector decreased, mass distributions were more concentrated in the center region.

  • PDF

Tomographic reconstruction of Asymmetric Spray by Direct Sampling Method (직접샘플링에 의한 비대칭 분무의 토모그래피 재구성)

  • Lee, C.H.;Won, J.C.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2002
  • Convolution Fourier transformation tomographically reconstructs the spatially resolved spray injection rate from direct measuring cells. Asymmetric sprays generated from a twin-hole air shroud injector are tested with 12 equiangular projections of measurements. For each projection angle, line of sight integrated injection rate was measured at 35 positions with equal spacing measuring cells of 3 mm in width, 100 mm in length, 55 mm in depth and 0.5 mm thickness of separating wall. Interpolated data between the projection angles effectively increase the number of projections, which significantly enhances the signal-to-noise level in the reconstructed data. This modified convolution Fourier transformation scheme predicts well the structure of asymmetric sprays. Comparative study has been made between sprays with and without air shrouding. Tomograhpic reconstruction of injection rate from direct measuring cells obtained can be used to estimate the accuracy of volume fraction of spray from the LDPA tomographic reconstruction.

  • PDF