• Title/Summary/Keyword: spray frequency

Search Result 120, Processing Time 0.031 seconds

Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures (스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험)

  • Sim, Kyuho;Jeong, Min-Seong;Lee, Yoon-Pyo;Jang, Seon-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.

Spray Characteristics of a Pressure Swirl Nozzle for an Ambient Condition due to Flash Boiling (감압 비등에 의한 상압 환경에서의 압력식 와류 노즐의 분무 특성)

  • Kim, Won-Ho;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.686-691
    • /
    • 2010
  • Flash boiling takes place when the thermodynamic state of the liquid deviates from its saturation limit over which the liquid temperature exceeds by a certain degree of superheat. The liquid jet introduced into the lower pressure zone than the liquid saturation pressure experiences a sequence of the atomization and disintegrated into numerous faster and smaller droplets. In the present study spray characteristics for a flash swirl spray were experimentally investigated. Injectant temperature is raised by a high frequency dielectric heating method and local spray characteristics are instantly measured by Global Sizing Velocimetry (GSV, TSI Inc.). Dependence of dimensionless superheat degree and injection pressure on total and local SMDs and mean droplet size is quantitatively examined. The flash swirl spray has the relation in the injection pressure and nozzle diameter in order to determine the spray quality, including the dimensionless superheat degree. Small droplets occur in the void core and local droplet size distributions largely depend on the dimensionless superheat degree and the injection pressure.

  • PDF

An Experimental Study on the Electrohydrodynamic Atomization of Conducting Liquid Using the AC High Voltages (교류 고전압을 이용한 대전액체의 전기수력학적 미립화에 관한 실험적 연구)

  • Sung, K.A.
    • Journal of ILASS-Korea
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • An experimental study was performed to explore the drop formation and atomization characteristics in electrohydrodynarnic atomization with flow rate, power supply, voltage frequency, and nozzle size. A basic electrohydrodynarnic atomizer equipment was developed for the analysis of spray visualization and tested for the exploration of relationship between several experimental parameters. In results, the varicose wave had been taken place and the small droplets had been generated less than outer diameter of nozzle on the conditions of 25G of nozzle, flow rate of 2 mL/min, and applied frequency of 50kV at AC power over 5kV voltage. The whipping motion had been grown at applied frequency of 400kV and AC power around 2kV voltage

  • PDF

Improvement of the Efficiency of a Twin-fluid Nozzle using Ultrasonic Vibration (초음파 가진을 이용한 2-유체 노즐의 효율 향상)

  • 주은선;나우정;정진도;송민근;이경열
    • Journal of Biosystems Engineering
    • /
    • v.27 no.4
    • /
    • pp.317-326
    • /
    • 2002
  • Characteristics of a twin-fluid spray with ultrasonic vibration were examined in order to obtain a high efficiency of cold-fog spray of the automatic pest control machine which has been widely used in protected horticulture recently. An electrostrictive vibrator of PZT BLT and a magnetostrictive $\pi$-type vibrator were used applied as the ultrasonic transducers with a frequency of 28 kHz. All experiments were conducted in 4 methods of spray ; a conventional spray method without ultrasonic forcing, an indirect vibration method with ultrasonic forcing, an improving-quality method by ultrasonic forced within liquid, and a combined-use method with both of the indirect vibration method and the improving quality method. It was found that the ultrasonic energy increased the atomization efficiency of spray droplets about 10% and especially much more in the case of the combined-use method.

An Accurate Method to measure Shielding Effectiveness of EMI Spray Coating Film (EMI 스프레이 코팅막의 차폐효과를 측정하기 위한 정확한 방법)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.79-83
    • /
    • 2018
  • An accurate method to measure shielding effectiveness(SE) of EMI spray coating film is presented. After high frequency simulating, Circular coaxial standard test fixture is fabricated. A sample of EMI spray coating film was fabricated for insertion into a circular coaxial standard test fixture. The measuring instrument used an Agilent 8722ES vector network analyzer for the SE measurement. The exact SE of copper and silver mixed spray coating sample was measured by the composition of the measuring instrument and the measuring sample. The SE of copper sample was measured at 70 dB and the SE of copper and silver mixed spray coating sample was measured at 60 dB. As a result of the measurement, the reliability of the circular coaxial standard test fixture was confirmed.

Tensile Analysis of Plasma Spray Coating Material by Classification of AE Signals (Acoustic Emission 파형분류에 의한 플라즈마 용사 코팅재의 인장해석)

  • ;;K. ONO
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.60-65
    • /
    • 2001
  • Thermal spray coating is formed by a process in which melted particles flying with high speed towards substrate, then crash and spread on the substrate surface cooled and solidified in a very short time, Stacking of the particles makes coating. In this study, the exfoliation of $Al_2$O$_3$ and Ni-4.5wt.%Al thermally sprayed coating which were deposited by an atmospheric plasma spray apparatus are investigated using an AE method. A tensile test is conducted on notch specimens in a stress range below the elastic limit of substrate. The wave forms of AE generated from the three coating specimens can be classified by FFT analysis into two types which low frequency(type I waveform is considered to corresponds exfoliation of coating layers and type II waveform corresponds the plastic deformation of notch tip or the resultant fracture of coating. The fracture of the coating layers can estimate by AE event and amplitude, because AE features increase when the deformation generates.

  • PDF

Effects of Benomyl Application on Phomopsis Seed Decay of Early Soybeans (조생종 콩의 Phomopsis 종자부패에 대한 베노밀 처리효과)

  • 이충식;박은우;김홍식;김석동;홍은희;고문환
    • Korean Journal Plant Pathology
    • /
    • v.10 no.3
    • /
    • pp.222-227
    • /
    • 1994
  • Effects of field applications of benomyl on Phomopsis seed decay of early soybeans were investigated at Suwon in 1992 and 1993. Pod and immature seed infections were markedly suppressed by benomyl application at the R6 stage whereas the spray at the R7 stage was not as effective as the spray at R6. When compared with unsprayed plots, benomyl spray at R6 resulted in decrease in Phomopsis seed infection by 37.1% and 73.9%, and increased in frequency of seed germination by 1.8% and 8.0% in 1992 and 1993, respectively. The results indicated that only one spray at early R6 could effectively reduce seed infection by Phomopsis spp.and could be adopted in a disease management program for commercial production of healthy soybean seeds.

  • PDF

PRESSURE MODULAION ON MICRO-MACHINED PORT FUEL INJECTOR PERFORMANCE

  • Kim, H.;Im, K.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • An experimental study was carried out to characterize the spray atomization process of micro-machined port fuel injectors with a piezoelectric atomization device, which can generate pressure pulsations through vibration of a piezoelectric transducer. In this study, several types of micro-machined arrays such as 30∼200-microns of hole arrays were tested. Both a dual-stream and a central-port injectors with micro-machined arrays were tested and compared with normal port fuel injectors. The spray visualization was conducted to characterize overall spray structure and phase Doppler particle analyzer (PDPA) system was used to quantify the droplet size and velocity. In addition, the pressure history was recorded by using digitized signal from pressure transducer. The results showed that modulation is effective to the spray atomization for tested injectors and atomization performance depends on injector design factors, orifice sizes, and frequency and power of the modulator. A number of resonance frequencies of the modulator was modified by injector parameters and temperature. In addition, our results suggested that design of sufficient space among holes is critical to avoid droplet coalescence in the multi-hole micro-machined injectors.

Post-infectional Activities of Non-systemic Fungicides Against Apple White Rot

  • Park, Chang-Hee;Hyun Woo;Kim, Dae-Hee;Uhm, Jae-Youl
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.92.1-92
    • /
    • 2003
  • In order to develop an effective spray program for control of apple white rot with reduced use of fungicides, the control efficacy of several fungicides that has been intensively used for control of the disease was assessed. They were sprayed on the same tree with 15 day interval from late May to early August. Just prior to and after each spray, 100 fruits were bagged with two layered fruit bag to limit the chemical application in only one time, and the disease incidence and latent infection frequency on the bagged apples were examined. Some fungicides such as folpet, iminoctadine-triacetate and azoxystrobin showed a high post-infectional activity even though the former two are non- systemic. Folpet suppressed symptom development, iminoctadine-triacetate reduced infection frequency and azoxystrobin acted in both ways. When those fungicides were !! adopted in a spray program, once in a cropping season, their post-infectional activity became much greater. This activity shown by the non-systemic fungicides was supposed to be derived from the peculiar infection process of the white rot fungus of which the pathogen is usually remain latent in the corked cells of lenticel until the apple reach mature stage.

  • PDF