• Title/Summary/Keyword: spiral

Search Result 1,758, Processing Time 0.56 seconds

Study on velocity profiles around spiral baffle plates in a horizontal circular tube without inner tubes

  • Chang, Tae-Hyun;Lee, Kwon-Soo;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.403-411
    • /
    • 2016
  • Usually shell and tube heat exchangers are employed to recover energy between fluids. Recently, numerous papers on these heat exchangers have been published; however, the velocity and temperature profiles or comparison of the features of the flow with or without inside tubes have rarely been described. In this research, experimental and numerical studies were carried out to investigate the characteristics of the flow around the spiral baffle plates without inside tubes in a horizontal circular tube using a particle image velocimetry method and ANSYS 14.0~15.0 version (Fluent). The results showed that swirling flow was produced between the spiral baffle plates. The tangential components were strong between the two spiral baffles; however, the axial or radial velocities components were indicating nearly zero. From the spiral motion in the space of the two baffles, it is considered that there were no dead zones between the spiral baffle.

Effects of Spiral Taping in Motor Disturbance of the Neck Induced by Cervical Sprain -Randomized Clinical Controlled Trials-

  • Kwon, Ki-Rok
    • Journal of Acupuncture Research
    • /
    • v.23 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • Objectives : This study was conducted for objective verification of effects of spiral taping therapy for the patients with motor disturbance. Methods : To verify whether spiral taping therapy is effective for treating motor disturbance from cervical sprain, 28 patients were randomly allocated into the control and experiment groups. Then 23 subjects who fulfilled the experiment requirements were measured for lateral rotation angle using the goniometer. Changes in rotation were observed and compared. Control group received acupuncture and herbal acupuncture treatment, whileas the experiment group received spiral taping therapy in addition. Results : Differences in age and the degree of motor disturbance were disregarded in comparison of the groups prior to rendering treatments. For the control group, significant changes were observed after the second treatment until the termination of treatment. For the experiment group, significant changes were observed after the first treatment until the termination of treatment. Difference between the groups was insignificant but experiment group with spiral taping therapy showed better results. Conclusion : Spiral taping therapy can be an effective complementary treatment method for treating neck motor disturbance. Further studies in the subject should be conducted to yield more concrete verification.

  • PDF

Analysis and Design of a Spiral Antenna using Moment Method (모먼트법을 이용한 스파이럴 안테나의 해석 및 설계)

  • 한정세;이갑수;박병우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.5
    • /
    • pp.857-871
    • /
    • 1994
  • In this paper, six kinds of spiral antenna, a combination of two types of spiral arm-width and three types of spiral curvature are analyzed by using moment method. Dividing spiral arms into N sections, the current distribution is calculated by Galerkin`s method. The radiation pattern and the antenna gain are derived from antenna currents. All os the six spiral antenna have amni-dirctional and wide-band characteristics, although the antenna gain changes within +_ 5dB bound for operating range(600MHz-2GHz). The variation of antenna`s gain is caused by the return loss in connection the Balun to the antenna. Simulation and experimental results on the radiation pattern also show spiral antennas have omni-directional and wide-band characteristics.

  • PDF

Low Phase Noise VCO Using Spiral Resonator (Spiral 공진기를 이용한 저위상 잡음 전압 제어 발진기)

  • Jwa, Dong-Woo;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.7
    • /
    • pp.77-80
    • /
    • 2008
  • In this paper, low phase noise VCO using novel compact microstrip spiral resonator is proposed. A spiral resonator has super compact dimension, low insertion losses in the passband and high level of rejection in the stopband with sharp cutoff and a large coupling coefficient value, which makes a high Q value, and has reduced the phase noise. To increase the tuning range of VCO, varactor diode has been connected at the tunable negative resistance in VCO. This VCO has presented the oscillation frequency of $5.686{\sim}5.841GHz$, harmonics -29.83 dBc and phase noise of $-115.16{\sim}-115.17dBc/Hz$ at the offset frequency of 100 KHz.

Stress Analysis of Composite Double Lead Spiral in 20mm Universal Ammunition Loading System (20mm 범용탄약적재장비의 복합재 이중리드나선구조 설계)

  • Je, Hyun-Min;Kim, Wie-Dae
    • Composites Research
    • /
    • v.31 no.6
    • /
    • pp.340-346
    • /
    • 2018
  • This paper addresses the stress analysis and design of composite double lead spiral which is boarded in 20mm universal ammunition drum by finite element method. The spiral system is very important to transfer the ammunition in stable and reliable manners for aircraft. Some verifications are done to check the possibility of composite application in spiral system. The design variables, stacking sequence and fiber orientation angles, are investigated for reliable design for practical design. The Tsai-Wu failure theory is applied to see the safety of the spiral structure. The design result is suggested to manufacture the double lead spiral part.

Detection of Intrinsic Spin Alignments in Isolated Spiral Pairs

  • Koo, Hanwool;Lee, Jounghun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.79.3-79.3
    • /
    • 2019
  • Observational evidence for intrinsic galaxy alignments in isolated spiral pairs is presented. From the catalog of the galaxy groups identified by Tempel et al. in the flux-limited galaxy sample of the Sloan Digital Sky Survey Data Release 10, we select those groups consisting only of two spiral galaxies as isolated spiral pairs and investigate if and how strongly the spin axes of their two spiral members are aligned with each other. We detect a clear signal of intrinsic spin alignment in isolated spiral pairs, which leads to the rejection of the null hypothesis at the 99.9999% confidence level via the Rayleigh test. It is also found that those isolated pairs comprising two early-type spiral galaxies exhibit the strongest signal of intrinsic spin alignment and that the strength of the alignment signal depends on the angular separation distance as well as on the luminosity ratio of the member galaxies. Using the dark matter halos consisting of only two subhalos resolved in the EAGLE hydrodynamic simulations, we repeat the same analysis but fail to find any alignment tendency between the spin angular momentum vectors of the stellar components of the subhalos, which is in tension with the observational result. Several possible sources of this apparent inconsistency between the observational and the numerical results are discussed.

  • PDF

Detection of Intrinsic Spin Alignments in Isolated Spiral Pairs

  • Koo, Hanwool;Lee, Jounghun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.35.2-35.2
    • /
    • 2019
  • Observational evidence for intrinsic galaxy alignments in isolated spiral pairs is presented. From the catalog of the galaxy groups identified by Tempel et al. in the flux-limited galaxy sample of the Sloan Digital Sky Survey Data Release 10, we select those groups consisting only of two spiral galaxies as isolated spiral pairs and investigate if and how strongly the spin axes of their two spiral members are aligned with each other. We detect a clear signal of intrinsic spin alignment in isolated spiral pairs, which leads to the rejection of the null hypothesis at the 99.9999% confidence level via the Rayleigh test. It is also found that those isolated pairs comprising two early-type spiral galaxies exhibit the strongest signal of intrinsic spin alignment and that the strength of the alignment signal depends on the angular separation distance as well as on the luminosity ratio of the member galaxies. Using the dark matter halos consisting of only two subhalos resolved in the EAGLE hydrodynamic simulations, we repeat the same analysis but fail to find any alignment tendency between the spin angular momentum vectors of the stellar components of the subhalos, which is in tension with the observational result. Several possible sources of this apparent inconsistency between the observational and the numerical results are discussed.

  • PDF

Immediate Effect of the Proprioceptive Spiral Taping Method on Changes in Muscle Stiffness (고유수용성감각 촉진을 위한 나선형 테이핑 방법이 근육 경도 변화에 미치는 즉각적인 효과)

  • Yang, Jae-Man
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.321-329
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the immediate effect on the change in muscle stiffness in the common extensor muscle (CEM) when using the spiral taping method to promote proprioception. Methods: There were 18 participants in this study. CEM stiffness was measured using a MyotonePRO device with the subject in a sitting position and according to the proprioceptive neuromuscular facilitation (PNF) arm pattern. Elastic tape was used as the material for the three taping methods employed in the study: kinesiotaping (KT), right spiral taping (RST), and left spiral taping (LST). The taping methods were applied to the wrist extensor muscle with elongation position. Additionally, when performing PNF arm patterns, spiral taping in diagonal and spiral directions was used to promote CEM proprioceptors. The change in CEM stiffness was compared with the initial data values. Results: The results of this study were obtained by comparing and measuring changes in CEM stiffness using three different tapings. It was found that the stiffness change of the CEM was significant compared to the initial value, and the increase in stiffness of the CEM after RST application was also significant. Conclusion: The results of this study show that by affecting the strength and activation of the extensor muscle, taping performed through the RST method had the most positive effect on the change in CEM stiffness.

A Technique for Reducing the Size of Microwave Amplifiers using Spiral-Shaped Defected Ground Structure (맴돌이형 결함접지구조를 이용한 마이크로파 증폭기의 소형화 방법)

  • Lim, Jong-Sik;Jeong, Yong-Chae;Ahn, Dal;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.904-911
    • /
    • 2003
  • A new method to reduce the size of microwave amplifiers spiral-shaped defected ground structure(Spiral-DGS) is proposed. A microstrip line having Spiral-DGS on the ground plane produces increased slow-wave factor and electrical length for the fixed physical length. In addition, it provides an excellent rejection characteristic for a finite frequency band like band rejection filters. The rejection band is used for rejecting harmonic components of amplifiers. The reduced microstrip line lengths in matching networks by Spiral-DGS are 39 % and 44 % of the original ones in input and output matching networks, respectively. It is shown that the measured S-parameters of the reduced amplifier agree well with those of the original amplifier. The measured second harmonic of the reduced amplifier is much less than that of the original amplifier by at least 10 dB. The same technique is applied to reject the third harmonic using the proper Spiral-DGS for the third harmonic frequency. The measured third harmonic is smaller than that of the original amplifier by 25 dB.

Structure of the Double Four-spiral Semigroup

  • CHANDRASEKARAN, V.M.;LOGANATHAN, M.
    • Kyungpook Mathematical Journal
    • /
    • v.43 no.4
    • /
    • pp.503-512
    • /
    • 2003
  • In this paper, we first give an alternative description of the fundamental orthodox semigroup $\bar{A}$(1, 2). We then use this to represent the double four-spiral semigroup $DSp_4$ as a regular Rees matrix semigroup over $\bar{A}$(1, 2).

  • PDF