경유와 메탄올의 유출속도에 따른 화재특성 (Fire Characteristics for Spill Rate of Light oil and Methanol)

  • 이정윤;김홍
    • 한국안전학회지
    • /
    • 제31권5호
    • /
    • pp.54-60
    • /
    • 2016
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate. Depending on spill rate(30, 60, 90 and $120{\ell}/min$) and the longer the duration of the flame important factors for the internal temperature of tank lorry rise was found. Road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

경유와 메탄올의 유출표면에 따른 화재특성에 관한 실험적 고찰 (An Experimental Investigation on Fire Characteristics of Light Oil & Methanol for Spilled Surface)

  • 이정윤;정기창;김홍
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.103-108
    • /
    • 2010
  • In this study, tank truck incidents of road transport of hazardous materials to experimental investigated the potential fire hazard. Real scale fire was to perform experiments for on this qualitative and quantitative data collection and analysis. Particularly affected by radiant heat from the flames caused and damage estimates range investigated accordingly. Flame temperature, internal temperature of tank and emitted radiation from the flames was investigated. The flame of light oil spill caused a fire at a temperature of about $300^{\circ}C$ high in comparison with the methanol by combustion of diesel and methanol, according to the difference, the flame duration changes varies depending on the Burning rate, amount of radiant heat flux from light oil fire was 4 times increases compared with fire of methanol. Depending on spill locations(kinds of road surfaces, absorbing rate) and the longer the duration of the flame important factors for the internal temperature of tank truck rise was found. Dirt roads than paved road accident in a fire caused by leakage of hazardous was could the higher the damaged. Therefor, Fire suppression activities should be required in particular to be around.

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

멕시코만의 BP사 오일유출 해저 대책에 대한 분석 (Subsea Responses to the BP Oil Spill in the Gulf of Mexico)

  • 최한석;이승건;도창호
    • 한국해양공학회지
    • /
    • 제25권3호
    • /
    • pp.90-95
    • /
    • 2011
  • On April 20, 2010, a well control event allowed hydrocarbon (oil and gas) to escape from the Macondo well onto Deepwater Horizon (DWH), resulting in an exploration and fire on the rig. While 17 people were injured, 11 others lost their lives. The fire continued for 36 hours until the rig sank. Hydrocarbons continued to flow out from the reservoir through the well bore and blowout preventer (BOP) for 87 days, causing an unprecedented oil spill. Beyond Petroleum (BP) and the US federal government tried various methods to prevent the oil spill and to capture the spilled oil. The corresponding responses were very challenging due to the scale, intensity, and duration of the incident that occurred under extreme conditions in terms of pressure, temperature, and amount of flow. On July 15, a capping stack, which is another BOP on top of the existing BOP, was successfully installed, and the oil spill was stopped. After several tests and subsea responses, the well was permanently sealed by a relief well and a bottom kill on September 19. This paper analyzes the subsea responses and engineering efforts to capture the oil, stop the leaking, and kill the subsea well. During the investigation and analysis of subsea responses, information was collected and data bases were established for future accident prevention and the development of subsea engineering.

가구(침대)의 유류방화 특성에 관한 실험적 연구 (An experimental study on the fire characteristics of liquid accelerant over furniture(mattress))

  • 김수영
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.235-240
    • /
    • 2010
  • 본 연구는 침대 매트리스를 초기 가연물로하여 소량의 인화성 액체를 사용한 방화 화재 특성에 관한 실험적 연구로서 인화성액체의 spill형태에 따른 가연물의 연소속도, 연소 Patterns의 분석과 동일한 공간 가연물에서 일반화재와 유류방화의 비교 실대 화재 실험 및 실험 현장에서 수거한 유류증거물의 인화성액체 종류별, 증거물의 상태에 따른 GC/Mass 분석 결과특성에 관한 연구이다.

  • PDF

A Study on the Development of Advanced Model to Predict the Sodium Pool Fire

  • Lee, Yong-Bum;Park, Seok-Ki
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.240-250
    • /
    • 1997
  • Liquid sodium is widely used as a coolant of LMR(Liquid Metal Reactor) because of its physical and nuclear properties. However, the liquid sodium is very chemically reactive with oxygen and water so that the study on the sodium fire plays an important role in the LMR safety analysis. In this study, a sodium fire model is suggested to analyze the sodium pool fire where both the flame and the reaction products are considered. And also, sodium pool fire analysis computer code, SOPA, is developed. The sensitivity study on the experimental parameters such as the thermal radiation from flame to atmospheric gas, the vessel cooling and the duration of sodium spill was performed. The results showed good agreements with experimental data in the literature.

  • PDF

미분무 소화시스템을 이용한 철도차량 실물화재 진압실험 (Fire Suppression Tests for a Train Using Water Mist Systems)

  • 최병일;한용식;도규형;김명배;이동찬
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.57-65
    • /
    • 2009
  • 미분무 소화시스템을 이용하여 철도차량 내부 화재진압 실험을 수행하였다. 실험차량은 실물 철도차량이며, 화재시나리오는 표면화재 1종, 유류화재 1종, 그리고 미분무 소화시스템에 의한 화재 공간 내의 공간 냉각 능력을 조사하기 위한 차폐화재 1종 등 총 3종이었다. 실험에 사용된 소화시스템은 6종으로, 일정압력을 가지는 소화시스템 5종, 질소가압 압력용기로부터 분사되는 소화시스템 1종이다. 실험 결과 미분무 소화시스템이 철도 차량 내부의 화재를 효과적으로 소화시키거나, 소화가 되지 않더라도 우수한 공간 냉각 능력으로 화재 피해를 최소화할 수 있음을 알았다.

Modeling and simulation of large crowd evacuation in hazard-impacted environments

  • Datta, Songjukta;Behzadan, Amir H.
    • Advances in Computational Design
    • /
    • 제4권2호
    • /
    • pp.91-118
    • /
    • 2019
  • Every year, many people are severely injured or lose their lives in accidents such as fire, chemical spill, public pandemonium, school shooting, and workplace violence. Research indicates that the fate of people in an emergency situation involving one or more hazards depends not only on the design of the space (e.g., residential building, industrial facility, shopping mall, sports stadium, school, concert hall) in which the incident occurs, but also on a host of other factors including but not limited to (a) occupants' characteristics, (b) level of familiarity with and cognition of the surroundings, and (c) effectiveness of hazard intervention systems. In this paper, we present EVAQ, a simulation framework for modeling large crowd evacuation by taking into account occupants' behaviors and interactions during an emergency. In particular, human's personal (i.e., age, gender, disability) and interpersonal (i.e., group behavior and interactions) attributes are parameterized in a hazard-impacted environment. In addition, different hazard types (e.g., fire, lone wolf attacker) and propagation patterns, as well as intervention schemes (simulating building repellent systems, firefighters, law enforcement) are modeled. Next, the application of EVAQ to crowd egress planning in an airport terminal under human attack, and a shopping mall in fire emergency are presented and results are discussed. Finally, a validation test is performed using real world data from a past building fire incident to assess the reliability and integrity of EVAQ in comparison with existing evacuation modeling tools.

침몰선박의 관리를 위한 위해도 평가시스템 개발 (Development of the Risk Assessment Systems for Management of Sunken Ships)

  • 최혁진;류재문;김홍태;이승현;강창구
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제8권4호
    • /
    • pp.193-202
    • /
    • 2005
  • 본 논문에서는 침몰선박이 보유하고 있는 모든 위해요인을 체계적으로 규명하고, 위해요인으로 인한 손실정도를 정량적으로 산출하여 효과적이고 일관된 침몰선박 관리와 과학적이고 경제적인 침몰선박 처리 의사결정에 활용할 수 있는 침몰선박 위해도 평가모델 및 정보시스템의 개발내용을 소개하고자 한다.

  • PDF

식물성절연유의 가속열화에 따른 장기적 안정성 분석 (Research of Accelerated Aging According to Long-term Stability of Vegetable Oil)

  • 최순호;허창수
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1148-1152
    • /
    • 2012
  • The vegetable-based insulating oils are substitutes for mineral oils in oil-filled transformer. The important properties of vegetable insulating oil is their higher flash/fire point and biodegradability than conventional mineral oils. The large oil-filled transformer eliminate the risk of explosion and fire should the transformer fail and oil ignite owing to high flash/fire point of vegetable insulating oil. In addition, higher biodegradability of vegetable insulating oils can let the oil spill damage reduced. In this experiment, the real oil-filled transformers using mineral oil and vegetable oil have accelerated aging. After working on the 100% accelerated aging experiment were conducted comparing the transformer. The hottest-spot temperature using thermal coefficients were calculated to determin the degree of accelerated aging. As a result, apply mineral oil transformer in accordance with the accelerated aging life come to an end. In contrast, vegetable insulating oils showed the opposite characteristics. Vegetable insulating oil compared to the mineral oil are found to be an long life. As a result, the vegetable oil has a long-term stability.