• Title/Summary/Keyword: spiking

Search Result 179, Processing Time 0.029 seconds

A Nucleic Acid Amplification Tests for Reliable HCV RNA Detection Method for Plasma-Derived Products (핵산증폭시험을 이용한 혈장분획물질에서 HCV RNA 검출)

  • Hong, Seung-Hee
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.293-298
    • /
    • 2008
  • HCV is transmitted via various plasma derived products. Current methods to detect hepatitis C virus (HCV) are based on its antibody detection in the donated blood and plasma. Viral contamination can potentially escape such detection during the window period of infection, when no antibody is present or the level of antibody is too low to detect. It is trying to application of nucleic acid amplification tests (NAT) for the direct detection of HCV. The objective of this study was to develop a reliable NAT for the HCV RNA detection from plasma-derived products. The most useful primers was selected for NAT among 5 sets of primers. We have also found that QIAamp viral RNA isolation kit was the most efficient for HCV RNA isolation. The highest sensitivity and specificity was appeared in $48^{\circ}C$ annealing temperature and 30 pmol of primers. With a spiking of HCV to albumin, immunoglobulins and coagulation factors, NAT can detect up to 100 IU/ml. Meanwhile, COBAS amplicor HCV 2.0 afforded a lower sensitivity in high concentrated intramuscular immunoglobulins to below 500 IU/ml. Our results suggested that NAT appears to be a highly sensitive and specific method for HCV RNA detection in plasma-derived products.

Short-term Nutrient Enrichment Bioassays (NEBs) by Manipulation of TN:TP Ratios and the Response of Primary Productivity (as Chlorophyll-a) (N:P Ratio 조절에 의한 단기 영양염 첨가 바이오에세이(NEBs) 및 1차 생산력(엽록소-a)의 반응성 테스트)

  • Jeong, Da-Bin;An, Kwang-Guk
    • Korean Journal of Environmental Biology
    • /
    • v.31 no.4
    • /
    • pp.383-392
    • /
    • 2013
  • The objective of this study was to determine the effects of N:P ratio on primary productivity measured as chlorophyll-a (CHL) using the approach of In Situ Nutrient Enrichment Bioassays (NEBs) in Daechung Reservoir. The effects of NEBs on the N:P mass ratios were compared with the field data obtained from monthly-chemical monitoring during 2009~2012. The short-term NEBs showed that the response of primary productivity in the phosphorus spiked treatments (5, 15, 20 and 30 N:P ratios) were greater than the responses in the control (C) and nitrogen spiked treatment (N:P ratio=150, $T_{VI}$). The response in the nitrogen treatment (N:P ratio=150, $T_{VI}$) was less compared to control and all five treatments ($T_I{\sim}T_{VI}$). The outcomes of the NEBs suggest that phosphorus limited the phytoplankton growth and nitrogen addition inhibited the algal growth. In the analysis of nutrients and CHL from the ambient epilimnetic water in Daechung Reservoir, minimum N:P ratios resulted in maximum concentrations of CHL. Overall, our results suggest that the N:P ratio was the key factor in regulating the phytoplankton growth in NEB experiments.

Pd/Si-based Emitter Ohmic Contacts for AlGaAs/GaAs HBTs (AlGaAs/GaAs HBT 에미터 전극용 Pd/Si계 오믹 접촉)

  • 김일호
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.218-227
    • /
    • 2003
  • Pd/Si/Ti/Pt and Pd/Si/Pd/Ti/Au ohmic contacts to n-type InCaAs were investigated for applications to AlGaAs/GaAs HBT emitter ohmic contacts. In the Pd/Si/Ti/Pt ohmic contact, as-deposited contact showed non-ohmic behavior, and high specific contact resistivity of $5\times10^{-3}\Omega\textrm{cm}^2$ was achieved by rapid thermal annealing at $375^{\circ}C$/10 sec. However, the specific contact resistivity decreased remarkably to $2\times10^{-6}\Omega\textrm{cm}^2$ by annealing at $425^{\circ}C$/10sec. In the Pd/Si/Pd/Ti/Au ohmic contact, minimum specific contact resistivity of $3.9\times10^{-7}\Omega\textrm{cm}^2$ was achieved by annealing at $400^{\circ}C$/20sec. In both ohmic contacts, low contact resistivity and non-spiking planar interface between ohmic materials and InGaAs were maintained. Therefore, these thermally stable ohmic contact systems are promising candidates for compound semiconductor devices. RF performance of the AlGaAs/GaAs HBT was also examined by employing the Pd/Si/Ti/Pt and Pd/Si/Pd/Ti/Au systems as emitter ohmic contacts. Cutoff frequencies were 63.9 ㎓ and 74.4 ㎓, respectively, and maximum oscillation frequencies were 50.1 ㎓ and 52.5 ㎓, respectively. It shows very successful high frequency operations.

Two Cases of Pancreatitis in Children with Hemolytic Uremic Syndrome (용혈성 요독 증후군에서 발생한 췌장염 2례)

  • Park Jee-Min;Kim Ki-Sung;Nam Young-Mi;Kim Eun-Soo;Ahn Sun-Young;Shin Jae-Il;Lee Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.7 no.2
    • /
    • pp.211-216
    • /
    • 2003
  • An epidemic outbreak of food poisoning due to enterohemorrhagic Escherichia coli(EHEC) occurred throughout Korea from May to September, 2003. Patients infected via contaminated school lunch foods were found mainly in Seoul and Gyeonggi province. As a result of this food poisoning, 36 patients were diagnosed as hemolytic uremic syndrome(HUS) up to mid-September, 2003 and five of them visited our hospital. Before the outbreak this year, we had experienced only 23 cases of HUS, including diarrhea associated (D+) and atypical (D-) forms, for the last 14 years, and there had been no case with pancreatic enzyme elevation. Unlike the past HUS cases, those of this year presented with severe abdominal pain and spiking elevation of pancreatic enzyme levels in 2 cases. We report 2 cases of transient pancreatitis combined with HUS in children during the epidemic outbreak in 2003 with a brief review of related literatures.

  • PDF

Determination of Phenol in Food using GC/MS (GC/MS를 이용한 식품 중 페놀 분석)

  • Kang, YoungWoon;Ahn, JiEun;Suh, JungHyuck;Park, Sunhee;Yoon, HaeJung
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.4
    • /
    • pp.312-315
    • /
    • 2014
  • The present study demonstrated the development and validation of the method for the quantification of phenol in food using gas chromatography coupled with mass spectrometry (GC-MS). After spiking of internal standard (Phenol-$d_5$) to food, those samples were extracted with organic solvent mixture (acetone : dichloromethane = 1 : 1, v/v) using ultra sonic extractor and cleaned by gel permeation chromatography (GPC) technique. The amount of phenol was determined by GC/MS. To validate the developed method, we evaluated parameters were the selectivity, linearity, accuracy, precision, and recovery. To demonstrate the selectivity of the method, blank samples of rice, corn, and fish(mackerel) were prepared and subjected to GC-MS analysis. To verify the linearity of the method, six different standard concentrations of phenol at 0.01, 0.05, 0.1, 0.5, 1 and 2.5 mg/kg were evaluated. The correlation coefficient ($r^2$) of calibration curve was 0.9999. The recovery rate for phenol standard calculated by internal standard method were 82.2~101.5% for samples fortified with 0.25, 0.50, and 1.0 mg/kg, respectively. Also the repeatability and reproducibility for validation of precision were 0.2~5.5%. According to the result of the validation, this established method was suitable for AOAC guideline. The limit of detection (LOD) for phenol analysis were 0.03~0.1 mg/kg, and the limit of quantification (LOQ) were 0.1~0.3 mg/kg. Therefore, we established the optimal analysis method for determination of phenol in food using GPC and GC/MS.

Effects of Electrical Stimulation on Ultrastructure of Plaice, Paralichthys olivaceus Muscle and Sarcoplasmic Reticulum (넙치 근육 및 근소포체 미세구조의 변화에 미치는 전기자극의 영향)

  • KIM Tae-Jin;KIM Young-Jin;YOON Ho-Dong;CHO Young-Je;CHOI Young-Jun;LEE Keun-Woo;KIM Geon-Bae;KIM Dong-Su
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.553-559
    • /
    • 1998
  • Electron micrographs of muscle of plaice killed instantly by spiking at the head clearly showed the A-band, I-band, Z-line and M-line in muscle strips, whereas these bands could not be distinguished from each other in electrically stimulated plaice muscle strips. As the electrical stimulation time increased, the continuity of Z-line disrupted rapidly. Electron microscopic observation showed that sarcoplasmic reticulum (SR) in unstimulated plaice had natural triad structures between Z-line. However these structures were disrupted in the electrically stimulated sample. These structures were clearly observed after storage for 10 hrs at $5^{\circ}C$ from all the samples. In association with the $Ca^{2+}$ translocation, $Ca^{2+}$-pyroantimonate deposits were observed at the inner part of SR immediately after spiked the plaice, However, $Ca^{2+}$-pyroantimonate deposits in electrically stimulated plaices were observed in the muscle strips and this phenomenon was clearly observed when electrical stimulation was prolonged.

  • PDF

Memristors based on Al2O3/HfOx for Switching Layer Using Single-Walled Carbon Nanotubes (단일 벽 탄소 나노 튜브를 이용한 스위칭 레이어 Al2O3/HfOx 기반의 멤리스터)

  • DongJun, Jang;Min-Woo, Kwon
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.633-638
    • /
    • 2022
  • Rencently, neuromorphic systems of spiking neural networks (SNNs) that imitate the human brain have attracted attention. Neuromorphic technology has the advantage of high speed and low power consumption in cognitive applications and processing. Resistive random-access memory (RRAM) for SNNs are the most efficient structure for parallel calculation and perform the gradual switching operation of spike-timing-dependent plasticity (STDP). RRAM as synaptic device operation has low-power processing and expresses various memory states. However, the integration of RRAM device causes high switching voltage and current, resulting in high power consumption. To reduce the operation voltage of the RRAM, it is important to develop new materials of the switching layer and metal electrode. This study suggested a optimized new structure that is the Metal/Al2O3/HfOx/SWCNTs/N+silicon (MOCS) with single-walled carbon nanotubes (SWCNTs), which have excellent electrical and mechanical properties in order to lower the switching voltage. Therefore, we show an improvement in the gradual switching behavior and low-power I/V curve of SWCNTs-based memristors.

Development of the Simultaneous Analysis of 36 Sulfonylurea Herbicide Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 제초제 Sulfonylurea계 36종 동시 시험법 개발)

  • Su Jung Lee;Jung Mi Lee;Gui Hyun Jang;Hyun-Kyung Kim;Ji Young Kim
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.2
    • /
    • pp.139-151
    • /
    • 2023
  • Sulfonylurea herbicides are widely used in agriculture because they have a long residual period and high selectivity. An analytical method was developed using QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) technique for simultaneous determination of sulfonylurea herbicide residues in agricultural products by liquid chromatography tandem mass spectrometry and for establishment MRL (Maximum Residue Limit) of those herbicides in Korea. Extraction was performed using acetonitrile containing 0.1% formic acid with MgSO4 (anhydrous magnesium sulfate) and NaCl (sodium chloride) and the extract was cleaned up using MgSO4 and C18 (octadecyl). The matrix-matched calibration curves were composed of 7 concentration levels from 0.001 to 0.25 mg/kg and their coefficients of determination (R2) exceeded 0.99. The recoveries of three spiking levels (LOQ, 10LOQ, 50LOQ, n=5) were in the range of 71.7-114.9% with relative standard deviations of less than 20.0% for all the five agriculture products. All validation values met criteria of the European Union SANTE/11312/2021 guidelines and Food and Drug Safety Evaluation guidelines. Therefore, the proposed analytical method was accurate, effective, and sensitive for sulfonylurea herbicide residues determination in agricultural commodities.

Evaluation for Application of IOM Sampler for Agricultural Farmer's Inhalation Exposure to Kresoxim-methyl and Fenthion (농작업자의 Kresoxim-methyl과 fenthion에 대한 호흡노출량 측정을 위한 IOM 채집기의 효율성 평가)

  • Lee, Jiho;Kim, Eunhye;Lee, Jonghwa;Shin, Yongho;Maasfeld, Wolfgang;Choi, Hoon;Moon, Joon-Kwan;Lee, Hyeri;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.230-240
    • /
    • 2015
  • An IOM sampler equipped with glass fiber filter has been recently utilized instead of solid adsorbent, which was used to measure the inhalation exposure of agricultural operator to pesticides. The aim of this study is to validate the efficacy of an IOM sampler by measuring the trapping efficiency and breakthrough using kresoxim-methyl water-dispersible granule and fenthion emulsifiable concentrate. On LC-MS/ MS, minimum detection level was 12.5 pg and method limit of detection was 5.0 ng/mL. Good linearity ($R^2$ > 0.999) for matrix matched standards was obtained. Recoveries of pesticides from glass fiber filter were 102-109% (kresoxim-methyl) and 97-104% (fenthion) while those from XAD-2 resin were 94-98% (kresoxim methyl) and 93-100% (fenthion). Trapping efficiency test was performed with personal air pumps and IOM sampler (glass fiber filter) connected with solid adsorbent (XAD-2 resin) with two types of formulation (solid and liquid) which were diluted by standard rate and sprayed to IOM sampler. Those pesticides were trapped only in glass fiber filter without any breakthrough to solid adsorbent. After spiking of pesticides to glass fiber filter, breakthrough test was carried out with IOM sampler (glass fiber filter) which was connected with solid adsorbent. As a results, 87-101% of kresoxim-methyl and 96-105% of fenthion remained in spiked glass fiber filter, however, no pesticides were detected in second glass fiber filter and solid adsorbent. In conclusion, IOM sampler which equipped with glass fiber filter can be applied widely for pesticide inhalation exposure study since it has good trapping efficiency and adsorption capacity, regardless of the solid or liquid formulation.

Simultaneous Determination of Eight Sugar Alcohols in Foodstuffs by High Performance Liquid Chromatography (HPLC를 이용한 식품 중 당알코올 8종 동시분석)

  • Lim, Ho-Soo;Park, Sung-Kwan;Kwak, In-Shin;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Jung-Yoon;Kim, So-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.1
    • /
    • pp.16-24
    • /
    • 2011
  • A method was established for the simultaneous determination of sugar alcohols, erythritol, xylitol, sorbitol, inositol, mannitol, maltitiol, lactitol and isomalt by High Performance Liquid Chromatography (HPLC). The sugar alcohols were converted into strong ultraviolet (UV)-absorbing derivatives with p-nitrobenzoyl chloride (PNBC). HPLC was performed on Imtakt Unison US-$C_18$ column, using acetonitrile: water (77:23) as a mobile phase and UV detection (260 nm). The calibration curves for all sugar alcohols tested were linear in the 10~200 mg/L range. The average recoveries of the sugar alcohols from three confectioneries spiked at 100 ppm of eight sugar alcohol standards ranged from 81.2 to 123.1% with relative standard deviations ranging fromo 0.2 to 4.9%. The limits of detection (LODs) were $0.5{\sim}8\;{\mu}g/L$ and the limits of quantification (LOQs) were $2{\sim}17\;{\mu}g/L$. Reproducibility of 8 sugar alcohols was 0.28~1.97 %RSD. The results of the analysis of confectioneries showed that 89 samples of 130 were detected and the sugar alcohols content of samples investigated varied between 0.4 and 693.7 g/kg. A method for the simultaneous determination of eight sugar alcohols will be used as basic data for control of sugar alcohols in confectioneries, and quality control in food manufacturing.