• Title/Summary/Keyword: spherical tank

Search Result 50, Processing Time 0.022 seconds

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Optimum Design of Moving Carrier for Minimizing Deflection in Al5083 Thick Plate (대면적 알루미늄 후판의 수평 이송을 위한 캐리어 최적설계)

  • Jeon, H.W.;Yoon, J.H.;Lee, J.H.
    • Transactions of Materials Processing
    • /
    • v.22 no.7
    • /
    • pp.389-393
    • /
    • 2013
  • One of the most efficient designs for manufacturing LNG tank is the Moss spherical type because it has been validated through precise analyses with respect to reliability and construction safety by stress analysis. The Moss spherical tank is assembled with hundreds of Al thick plate patches that are deformed to curved shape at elevated temperature and welded together. It is essential to evaluate the amount of deflection in the Al5083 thick plate when the patch is transferred from the heating chamber to the forming die since the patch has a length of 12,000 mm and a thickness of 60 mm. Based on FE analysis results, a design procedure for minimizing deflection in Al5083 thick plate during transfer using a moving carrier is demonstrated in this paper.

Liquid level control in a spherical tank by microcomputer (마이크로 컴퓨터를 이용한 구형 탱크의 액위 제어)

  • Kang, Won-Young;Oh, Min;Lee, Tae-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.459-462
    • /
    • 1986
  • The liquid level in a spherical tank was controlled with a micro-computer and the dynamic behavior of this non-linear system due to the variation of set point was studied. The adaptive control theory was used and the real values of controlled variables were compared with the theoretical values from a mathematical model.

  • PDF

Structural Safety Assessment of Independent Spherical LNG Tank(3rd report) - Safety assessment of tank system against crygenic temperature - (독립구형 LNG 탱크의 구조안전성 평가(제3보) - 탱크시스템의 저온 안전성 검토 -)

  • Yong-Yun Nam;In-Sik Nho;Ho-Sup Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.4
    • /
    • pp.83-92
    • /
    • 1993
  • This paper describes structural safety assessment techniques against crygenic temperature to design MRV type B LNG tank system. The following items are detail with in detail. (1) Leakage estimation of LNG through the propagating clacks at tank plate was performed and design of the range of catch basin(2ndary barrier) was followed to ensure the safety of ship structures against leaked LNG. (2) Temperature distribution analysis for cargo hold and skirt system was carried out using the steady state heat transfer analysis model for spherical LNG tank system. (3) Thermal stress distribution of skirt and tank system was calculated, where very stiff thermal variation was shwn through item(2) analysis.

  • PDF

Thermal Response and Sensitivity Analysis of Satellite Propulsion Tank (인공위성 추진제 탱크의 열적 반응 및 민감도 해석)

  • Han Cho Young;Lee Kyun Ho;Yu Myoung Jong
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.131-136
    • /
    • 2004
  • Thermal control of satellite propellant tank is achieved by patch heaters enabled by thermostat's behavior. It is important to attach the thermostat on the appropriate position of the propellant tank. However its position cannot be given with exact numerics because tank is spherical. Actually the position for thermostat is designated in relevant drawing approximately, therby, the engineer practices depending on his own experience and intuition. The sensitivity analysis for the position of thermostat is performed such that the influence on the thermal behavior and control of tank is examined quantatively. When assembling tank module, the reasonable performance on the thermal control is believed with possible human errors if the uncertainty in the position of thermostat is not quite large.

  • PDF

Analysis of Underwater Discharge Characteristics Caused by Impulse Voltages (임펄스전압에 의한 수증방전특성의 분석)

  • Choi, Jong-Hyuk;An, Sang-Duk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.2
    • /
    • pp.128-133
    • /
    • 2008
  • This paper describes underwater discharge phenomena and breakdown characteristics in case that the standard lightning impulse voltage is injected to the needle and spherical electrodes installed in the hemisphere water tank. The objective of this work is to understand the basic features related to transient ground impedance against lightning surges. The discharge luminous images were observed and the dependence of breakdown voltage on the polarity of applied voltage and water resistivity were investigated. As a consequence, streamer corona is initiated at the tip of needle and spherical electrodes and is propagated toward grounded tank with stepwise extension. The breakdown voltage characteristics measured as a function of water resistivity showed V-shaped curves. Breakdown voltage and time curve of needle electrode is higher than that of spherical electrode.

A Study on the Thermal Design of the Cryogenic LNG Carrier (초저온 LNG선의 열설계에 관한 연구)

  • 김용모;고상철;천병일;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.1-10
    • /
    • 1993
  • This paper introduces the outline of hull structure to the sorts of LNG carrier briefly. Especially, explains in detail for the insulation system of Moss Rosenberg Verft spherical tank type LNG carrier. It is not easy task to calculate exactly the temperature distribution of hull because of very complicated structure of hull. Therefore, in this paper by the adequate modeling of the Moss Rosengerg spherical tank type LNG carrier, a program is developed which calculate the temperature distribution of every hull and estimate the heat influx from every hull and output the BOR according to the variation of atmospheric conditions on boyage.

  • PDF

Structural Safety Assessment of Independent Spherical LNG Tank(2nd report) - Fatigue Crack Propagation Analysis Based on the LBF Theory - (독립구형 LNG 탱크의 구조안전성 평가(제2보) - LBF 이론에 의한 피로균열 진전해석 -)

  • In-Sik Nho;Yong-Yun Nam;Ho-Sup Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.4
    • /
    • pp.74-82
    • /
    • 1993
  • The present paper deals with the structural safety assessment techniques for independent type B spherical LNG tank against fatique crack initiation and propagation, which contains fellowing 3 steps. 1) Prediction of long term distribution of wave induced stresses and fatique crack intiation life using cumulative damage theory which were described at the 1st report. 2) Surface crack propagation analysis to verify that initial defects cannot penetrate tank plate. 3) Passing-through fatigue crack propagation analysis was performed based on LBF(Leak Before Failure ) theory.

  • PDF

Thermal performance of the spherical capsule system using paraffin as the thermal storage material (파라핀 축열재를 사용한 구형캡슐 시스템의 전열성능)

  • Cho, K.N.;Choi, S.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.354-363
    • /
    • 1997
  • The purpose of the present work is to show the best thermal storage material and the sensitivity of the parameters on the thermal performance by experimentally investigating the effects of the parameters on the thermal performance of the spherical capsule system using paraffins superior to the commercial one. The paraffins were n-Tetradecane and the mixture of n-Tetradecane 40% and n-Hexadecane 60%. The experimental parameters were the Reynolds number of 8, 12, and 16 and the inlet temperature of-7, -4, -1, and $2^{\circ}C$. The charging and the discharing time, the dimensionless thermal storage amount, and the averge heat transfer coefficient in the tank were obtained by utilizing the local temperature variation in the tank. The local charging and discharging time in the tank was axially and radially different a lot. The effects of the inlet temperature on the charging and the discharging time were larger during the charging process than during the discharging process, but the effects of the Reynolds number on the charging and the discharging time were in reverse order. The paraffins were better by 11~72% than the water with the inorganic material in the charging time aspect, but no difference in the discharging time aspect. The effects of the Reynolds number on the dimensionless thermal storage amount were smaller than the effects of the inlet temperature during the charging process, but in reverse order during the discharging process within the working range of the experimental parameters. The effects of the inlet temperature and the Reynolds number on the average heat transfer coefficient were larger during the discharging process than during the charging process. The average heat transfer coefficient for the paraffins was larger by 40% maximum than that for the commercial material during the charing and the discharging process.

  • PDF

FE-Analysis of Hot Forming of Al Large Thick Plate for Spherical LNG Tank Considering Cooling Performance of Grid-Typed Die (격자형 금형의 냉각효과를 고려한 구형 LNG 탱크용 대형 알루미늄 후판의 열간성형해석)

  • Lee, Jung-Min;Lee, In-Kyu;Kim, Dae-Soon;Kwon, Il-Keun;Lee, Seon-Bong;Kim, Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1190-1198
    • /
    • 2012
  • A hot forming of large thick Al plate using a grid-type hybrid die is a process to make a shell plate for the production of a spherical LNG tank. This process is characterized by using a grid-typed die with an additional air cooling system for reducing the cooling time of the heated plate after hot forming. The process consists of the plate's feeding, heating, forming and cooling in detail and each of them is continuously performed along the rail. This paper was designed to propose the analytical and experimental methods for determining the convection and interfacial heat transfer coefficients required in hot forming analysis of Al plate. These values in the analysis are to reproduce numerically the cooling performance of grid-typed die and cooling device. Interfacial heat transfer was obtained from the heat transfer experiments for different pressures and inverse analysis method. To verify the efficiency of the coefficient values obtained from above methods, FE analysis and experiment of the hot spherical-forming process were conducted for a small-scaled model. The convection coefficient was also calculated from flow analysis of air released by cooling device within grid-typed die using ANSYS-CFX.