• Title/Summary/Keyword: spectrum subtraction

Search Result 45, Processing Time 0.027 seconds

Extraction of the atmospheric path radiance in relation to retrieval of ocean color information from the TM and SeaWiFS imageries

  • Ahn, Yu-Hwan;Shanmugam, P.
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2004.03a
    • /
    • pp.241-246
    • /
    • 2004
  • The ocean signal that reaches the detector of an imaging system after multiple interactions with the atmospheric molecules and aerosols was retrieved from the total signal recorded at the top of the atmosphere (TOA). A simple method referred to as 'Path Extraction' applied to the Landsat-TM ocean imagery of turbid coastal water was compared with the conventional dark-pixel subtraction technique. The shape of the path-extracted water-leaving radiance spectrum resembled the radiance spectrum measured in-situ. The path-extraction was also extended to the SeaWiFS ocean color imagery and compared with the standard SeaWiFS atmospheric correction algorithm, which relays on the assumption of zero water leaving radiance at the two NIR wavebands (765 and 865nm). The path-extracted water-leaving radiance was good agreement with the measured radiance spectrum. In contrast, the standard SeaWiFS atmospheric correction algorithm led to essential underestimation of the water-leaving radiance in the blue-green part of the spectrum. The reason is that the assumption of zero water-leaving radiance at 755 and 865nm fails due to backscattering by suspended mineral particles. Therefore, the near infrared channels 765 and 865nm used fur deriving the aerosol information are no longer valid for turbid coastal waters. The path-extraction is identified as a simple and efficient method of extracting the path radiance largely introduced due to light interaction through the complex atmosphere carried several aerosol and gaseous components and at the air-sea interface.interface.

  • PDF

Sensitivity improvement of fiber-optic gyroscope with erbium-doped fiber source by source excess noise subtraction (Erbium 첨가 광섬유 광원을 사용하는 자이로스코프에서 광원 과잉잡음 소거에 의한 측정감도 개선)

  • 진영준
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1999.08a
    • /
    • pp.226-227
    • /
    • 1999
  • In the fiber-optic gyroscope employing the erbium-doped fiber source, the source excess noise was subtracted through a signal processing to improve the gyroscope sensitivity . As the result, we obtained the improvement of 14 dB(electrical) at the proper frequency, which was measured from the noise floor spectrum . In addition the random walk coefficient in the gyro output was reduced by about factor of three.

  • PDF

Car Noise Cancellation by Using Spectral Subtraction Method Based on a New Speech/nonspeech Classification Function (새로운 음성/비음성 분류함수에 기반한 스펙트럼 차감법에 의한 차량잡음제거)

  • 박영식;이준재;이응주;하영호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.6
    • /
    • pp.994-1003
    • /
    • 1994
  • In this paper, a scheme of noise cancellation using spectral subreaction method with single input in an autombile noise environment is proposed. In order to remove the changing automonile noise components form the noisy speech signal, the noise of various states is analyzed and its characteristics are presented. For the decision of speech/nonspeech and the estimation of noise spectrum, a classification function is proposed on the basis of noise analysis. This function presents the precise decision of speech/nonspeech and the optimal estimation of noise spectrum with less computation. As the result of the estimation of noise spectrum by the proposed classification function, the clean speech signal is extracted from the noisy speech signal with high signal-to-ratio.

  • PDF

The Effect of the Speech Enhancement Algorithm for Sensorineural Hearing Impaired Listeners

  • Kim, Dong-Wook;Lee, Young-Woo;Lee, Jong-Shill;Chee, Young-Joon;Lee, Sang-Min;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.732-743
    • /
    • 2007
  • Background noise is one of the major complaints of not only hearing impaired persons but also normal listeners. This paper describes the results of two experiments in which speech recognition performance was determined for listeners with normal hearing and sensorineural hearing loss in noise environment. First, we compared speech enhancement algorithms by evaluation speech recognition ability in various speech-to-noise ratios and types of noise. Next, speech enhancement algorithms by reducing background noise were presented and evaluated to improve speech intelligibility for sensorineural hearing impairment listeners. We tested three noise reduction methods using single-microphone, such as spectrum subtraction and companding, Wiener filter method, and maximum likelihood envelop estimation. Their responses in background noise were investigated and compared with those by the speech enhancement algorithm that presented in this paper. The methods improved speech recognition test score for the sensorineural hearing impaired listeners, but not for normal listeners. The results suggest the speech enhancement algorithm with the loudness compression can improve speech intelligibility for listeners with sensorineural hearing loss.

A Spectral Compensation Method for Noise Robust Speech Recognition (잡음에 강인한 음성인식을 위한 스펙트럼 보상 방법)

  • Cho, Jung-Ho
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.9-17
    • /
    • 2012
  • One of the problems on the application of the speech recognition system in the real world is the degradation of the performance by acoustical distortions. The most important source of acoustical distortion is the additive noise. This paper describes a spectral compensation technique based on a spectral peak enhancement scheme followed by an efficient noise subtraction scheme for noise robust speech recognition. The proposed methods emphasize the formant structure and compensate the spectral tilt of the speech spectrum while maintaining broad-bandwidth spectral components. The recognition experiments was conducted using noisy speech corrupted by white Gaussian noise, car noise, babble noise or subway noise. The new technique reduced the average error rate slightly under high SNR(Signal to Noise Ratio) environment, and significantly reduced the average error rate by 1/2 under low SNR(10 dB) environment when compared with the case of without spectral compensations.

Comparison of optical reflectance spectrum at blade and vein parts of cabbage and kale leaves

  • Ngo, Viet-Duc;Ryu, Dong-Ki;Chung, Sun-Ok;Park, Sang-Un;Kim, Sun-Ju;Park, Jong-Tae
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • Objective of the study was to compare reflectance spectrum in the blade and the vein parts of cabbage and kale leaves. A total 6 cabbage and kale leaves were taken from a plant factory in Chungnam National University, Korea. Spectra data were collected with a UV/VIS/NIR spectrometer (model: USB2000, Ocean Optics, FL, USA) in the wavelength region of 190 - 1130 nm. Median filter smoothing method was selected to preprocess the obtained spectra data. We computed reflectance difference by subtraction of averaged spectrum from individual spectrum. To estimate correlation at different parts of cabbage and kale leaves, cross - correlation method was used. Differences between cabbage and kale leaves are clearly manifested in the green, red and near - infrared ranges. The percent reflectance of cabbage leaves in the NIR wavelength band was higher than that of kale leaves. Reflectance in the blade part was higher than in the vein part by 18%. Reflectance difference in the different parts of cabbage and kale leaves were clear in all of the wavelength bands. Standard deviation of reflectance difference in the vein part was greater for kale, while the value in the blade part was greater for cabbage leaves. Standard deviation of cross - correlation increased from 0.092 in the first sensor (UV/VIS) and 0.007 in the second sensor (NIR) to 0.099 and 0.015, respectively.

A Study for Snoring Detection Based Artificial Neural Network (신경망 기반의 코골이 검출 알고리즘 개발에 관한 연구)

  • Jang, Won-Kyu;Cho, Sung-Pil;Lee , Kyung-Joung
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.327-333
    • /
    • 2002
  • In this study, we developed a snoring detection algorithm that detects snores automatically. It consists of preprocessing and snoring detection part. The preprocessing part is composed of a noise removal part using spectrum subtraction, and segmentation part, and computation part of temporal and spectral features. And the snoring detection part decides whether detected blocks are snores with BPNN(Back-Propagation Neural Network). BPNN with one hidden layer and one output layer, is trained with data of 7 subjects and tested with data of 11 subjects of total 18 subjects. The proposed algorithm showed a Sensitivity of 90.41% and a Predictive Positive Value of 84.95%.

Subtraction of excess noise in a gyroscope employing a high-power erbium-doped fiber source (고출력 Erbium 첨가 광섬유 광원을 사용하는 자이로스코프에서 광원 과잉잡음의 소거)

  • 진영준;박태용;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.396-400
    • /
    • 1999
  • In the fiber-optic gyroscope employing a high-power erbium-doped fiber source, the source excess noise was subtracted from the gyro output through a single processing to improve the gyroscope sensitivity. As the result, we obtained the reduction of noise by 13.5 dB (electrical) which was measured from the noise floor spectrum when the gyro was modulated with the depth of 1.8 rad. In addition, the random walk coefficient of the gyro output was reduced by a factor of 4~5.

  • PDF

A new method of Extracting the Filter Characteristics of the Nasal Cavity Using Homorganic Nasal-Stop Sequences: A Preliminary Report (동기관음의 스펙트럼 차이를 이용한 비강 특성 산출: 예비 연구)

  • Park, Han-Sang
    • MALSORI
    • /
    • no.53
    • /
    • pp.17-35
    • /
    • 2005
  • A New Method of Extracting the Filter Characteristics of the Nasal Cavity Using Homorganic Nasal-Stop Sequences: A Preliminary R eportHansang ParkThis study provides a new method of extracting the filter characteristics of the nasal cavity. Korean lenis stops are realized as voiced in the homorganic nasal-lenis stop sequences between vowels. Since the only difference between the two members of the homorganic nasal- lenis stop sequences, such as [mb], [nd], and [ g], is whether the passage to the nasal cavity is open or not, the subtraction of the LPC spectrum of the voiced stop from that of the preceding nasal leads to the filter characteristics of the nasal cavity of an individual speaker regardless of place of articulation. The results suggest that various attempts should be made to extract a robust filter characteristics of the nasal cavity by giving variation to LPC coefficients and by paying particular attention to speech samples. This study is significant in that it provides a preliminary report about a new method of extracting the filter characteristics of the nasal cavity.

  • PDF

Cerebral-perfusion Reserve after Carotid-artery Stenting: Relationship with Power Spectrum of Electroencephalography (경동맥스텐트삽입술 후의 뇌관류예비능: 뇌파파워스펙트럼과의 연관성)

  • Jeong, Da-hye;Jung, Seokwon;Kwak, Byeonggeun;Kim, Young-Soo;Kim, Soo-kyoung;Kwon, Oh-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.144-152
    • /
    • 2016
  • Carotid-artery stenosis may reduce cerebral perfusion, and affect cerebral neuronal activities. We examined the question of whether the recovery of cerebral-perfusion reserve after carotid-artery stenting (CAS) can affect the EEG power-spectrum. Nineteen candidates for CAS were initially recruited. Subtraction imaging of single photon emissary computerized tomography (SPECT) and an electroencephalogram (EEG) were taken twice, before and 1 month after CAS. At each time point, the EEGs were recorded before and after injection of acetazolamide (pre-ACZ EEG and post-ACZ EEG). Finally, 7 patients were enrolled after exclusion of incomplete studies. We obtained the spectral ratio (SR) of each hemisphere. SR was defined as the divided value of the power-spectrum sum of fast activities by that of slow activities. The power-spectrum values between hemispheres were compared using the inter-hemispheric index of spectral ratio (IHISR), and we examined the correlation between the power-spectrum and the cerebral-perfusion reserve. Cerebral-perfusion reserve improved after CAS on the stent side in 6 of 7 patients. In 3 patients with unilateral carotid-artery stenosis, CAS increased SR on the pre-ACZ EEGs, and IHISR on the post-ACZ EEGs. The increases of SR and IHISR were concordant with the increment of cerebral-perfusion reserve. In contrast, the results in the other patients with bilateral stenosis showed complex patterns. The SR of pre-ACZ EEGs and IHISR of post-ACZ EEGs may be useful electrophysiological markers for the blood-flow reserve after CAS in patients with unilateral carotid-artery stenosis, but not in those with bilateral stenosis.