• 제목/요약/키워드: spectrophotometry

검색결과 660건 처리시간 0.028초

Linear Sweep Voltammetry와 UV-VIS Spectrophotometry를 이용한 게르마늄 분석 (The Determination of Germanium(IV) by Linear Sweep Voltammetry and UV-VIS Spectrophotometry)

  • 최원형;이진식;김재수;김도훈
    • 분석과학
    • /
    • 제5권1호
    • /
    • pp.7-15
    • /
    • 1992
  • 게르마늄을 Phenylfluorone과 착물을 만들어 과염소산 지지전해질에서 Linear Sweep Voltammetry에 의해 정량하고, 염산용액 중에서 형성된 착물을 UV-VIS Spectrophotometry로 정량한 결과를 비교하였다. 이때 전기화학적인 방법의 경우 정량범위가 $2.5{\sim}80{\mu}g/L$이었고, 분광광도법의 경우는 $10{\sim}300{\mu}g/L$이었다.

  • PDF

무염 원자흡광도법과 흡광광도법에 의한 제제중의 Metoclopramide의 정량 (Determination of Metoclopramide by Flameless Atomic Absorption and Spectrophotometry)

  • 박만기;임병연;유경수;용군호
    • 약학회지
    • /
    • 제22권1호
    • /
    • pp.27-32
    • /
    • 1978
  • Metoclopramide reacts with ammonium cobaltothiocyanate to form a stable ion pair which has an absorption maximum of 625mm. The reaction product was insoluble in water but soluble in most organic solvents. 1,2-Dichlorethane was the best extracting solvent among the several organic solvents tested. Metoclopramide can be determinded not only by visible light spectrophotometry but also indirectly by estimation of cobalt in the organic phase by flameless atomic absorption spectrophotometry. Linear relationship was found between absorbance and concentration in the range of 10$^{-4/}$-10$^{-3}$M by spectrophotometry and 10$^{-5}$-10$^{-4}$M by flameless atomic absorption spectrophotometry. The coefficient of variation by spectrophotometry was 0.9% and that of flameless atomic absorption was 1.8%. There was no interference with excipients, pH, temperature and reaction time. With this method, it is possible to determine accurately metoclopramide and tertiary amines in pharmaceutical preparations.

  • PDF

흡광광도법 및 원자흡광광도법에 의한 Pipethanate$\cdot$HCl의 정량 (Determination of Pipethanate$\cdot$HCl by Spectrophotometry and Atomic Absorption Spectrophotometry)

  • 이왕규;박만기;김박광;손채연
    • 약학회지
    • /
    • 제27권4호
    • /
    • pp.303-307
    • /
    • 1983
  • Pipethanate*HCl reacts with ammonium cobaltothiocyanate to form a stable ion pair which has an absorption maximum at 626nm. The reaction product was insoluble in water but freely soluble in most organic solvents. 1, 2-Dichloroethane was the best extracting solvent among the several organic solvents. Pipethanate*HCl can be determined not only by the spectrophotometry but also inderectly by estimation of cobalt in the organic phase by atomic absorption spectrophotometry. Linear relationship was found between absorbance and concentration in the range of $1.0{\times}10^{-3}~4.0{\times}10^{-3}M$ by spectrophotometry and $1.5{\times}10^{-4}~4.0{\times}10^{-4}M$ by atomic absorption spectrophotometry. With this method it was possible to determine pipethanate$\cdot$HCl in the pharmaceutical preparations.

  • PDF

Drug-Biomacromolecule Interaction XII: Comparative binding study of sulfaethidole to bovine serum albumin by equilibrium dialysis, fluorescence probe technique, uv difference spectrophotometry and circular dichroism

  • Kim, Chong-Kook;Chun, Yang-Sook;Lah, Woon-Lyong
    • Archives of Pharmacal Research
    • /
    • 제12권3호
    • /
    • pp.160-165
    • /
    • 1989
  • Binding of sulfaethidole to bovine serum albumin was studied by equilibrium dialysis, fluorescence probe technique, uv difference spectrophotometry and circular dichroism. Equilibrium dialysis method enabled us to estimate the total number of drug binding sites of albumin molecule. For sulfaethidole, albumin had 6 primary and 40 secondary binding sites. The primary and secondary binding constants were 0.9 * 10/sup 5/ M/sup -1/ and 0.2 * 10/sup 6/ M/sup -1/, respectivitely. 1-Anilino-8-naphthalenesulfonate (ANS) and 2-(4-hydroxylbenzeneazo)- benzoic acid (HBAB) were used as the fluorescence probe and the uv spectrophotometric probe, respectively. In fluorescence probe technique, results indicated that the number of higher affinity drug binding site of albumin was 1 and the number of lower affinity drug binding sites of albumin was 3, and the primary and secondary drug binding constants for bovine serum albumin were 2.15 * 10/sup 5/M/sup -1/ and 1.04 * 10/sup 5/ M/sup -1/, respectively. In uv difference spectrophotometry, binding sites were 3 and binding constant was 1.88 * 10/sup 5/M/sup -1/. The above spectrophotometry, binding sites were 3 and binding constant was 1.88 * 10/sup 5/M/sup -1/. The above results suggest that several different methods should be used in ompensation for insufficient information about drug binding to albumin molecule given by only one method.

  • PDF

미분 분광 광도법에 의한 정량분석법 (제1보) -염산 피리독신과 니코틴아미이드 혼합물의 자외부에서의 분리정량- (Quantitative Analysis by Derivative Spectrophotometry (I) -Simulaneous quantitation of pyridoxine.HCI and nicotinamide in mixture by ultraviolet derivative spectrophotometry-)

  • 박만기;조영현;조정환
    • 약학회지
    • /
    • 제30권4호
    • /
    • pp.185-192
    • /
    • 1986
  • Authors developed the computer application program (language: APPLE SOFT BASIC) for derivative spectrophotometry. By means of this program, derivative of spectral absorbance with respect to wavelength is recorded versus wavelength. To try this program in connection with spectrophotometer system, the authors have done the simultaneous quantitation of pyridoxine center dot HCl and nicotinamide in the mixture, and the result was compared with that of absorbance method.

  • PDF

면천체(EXTENDED OBJECTS)에 대한 긴 슬릿 분광관측 연구 (LONG-SLIT SPECTROSCOPY FOR EXTENDED OBJECTS)

  • 성언창
    • 천문학논총
    • /
    • 제15권spc1호
    • /
    • pp.39-60
    • /
    • 2000
  • We will discuss two-dimmensional spectrophotometry including long-slit spectroscopy and narrow-band imaging. The basic principles, applications, and techniques of observations and data reduction of spectroscopy and spectrophotometry for extended objects are described. This discussion will focus on practical long-slit spectroscopy using a Cassegrain spectrograph attached with 2 or 4m class telescopes and on imaging spectrophotometry using narrow-band interference filter sets. We will discuss scientific applications.

  • PDF

Competitive Spectrophotometry for Microbial Dipeptide Transport Systems

  • Hwang, Se-Young;Ki, Mi-Ran;Cho, Suk-Young;Lim, Wang-Jin;Yoo, Ick-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • 제6권2호
    • /
    • pp.92-97
    • /
    • 1996
  • Portage kinetic constants of peptide transport can be measured by competitive spectrophotometry. The kinetic constants of L-Glu-L-Glu transport in Escherichia coli were ascertained using L-Phe-L-3-thia-Phe (PSP) as a detector. Since the production of thiophenol upon intracellular hydrolysis of PSP was competitively inhibited by L-Glu-L-Glu, it was able to compute the kinetic constants of L-Glu-L-Glu using this method. The resulted data were in agreement with the values obtained by the method of Michaelis-Menten kinetics. The potential of this method was examined against dipeptide transport systems in various microorganisms. These results strongly suggest that the overall properties of individual systems for dipeptide transports can be easily characterized by competitive spectrophotometry.

  • PDF

Quantitative analysis by derivative spectrophotometry (ll) Derivative spectrophotometry and methods for the reduction of high frequency noises

  • Park, Man-Ki;Cho, Jung-Hwan
    • Archives of Pharmacal Research
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 1987
  • One of the problems of derivatie spectrophotometry, the decrease of signal-to-noise ratio by derivative operations, was solved by three concepts of digital filtering, ensemble averaging, least squares polynomial smoothing and Fourier smoothing. The suthors made several compouter programs written in APPLE SOFT BASIC language for the actual applications of the concepts of these digital filters on UV spectrophotometer system. As a result, ensemble averaging could not be used as a routine operation for the spectrophotometer used. The maximum S/N ratio enhancement factors achieved by least squares polynomial smoothing were 6.17 and 7.47 for the spectra of Gaussian and Lorentzian distribution models, and by Fourier smoothing 16.42 and 11.78 for the spectra of two models, respectively.

  • PDF

Synthesis of Carbobenzoxy-alanyl-thiaarginine (thialysine) benzyl ester and kinetic Studies with Trypsin

  • 홍남주;장성훈;진동훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.689-695
    • /
    • 1998
  • Carbobenzoxy-alanyl-thiaarginine benzyl ester and carbobenzoxy-alanyl-thialysine benzyl ester were synthesized in solution. Kinetic studies were carried out using three different analytical methods, semi-classical method, progress curve analysis and competitive spectrophotometry. In competitive spectrophotometry, carbobenzoxy-valyl-glycyl-arginyl-p-nitroaniline was used as a detector. Kinetic constants such as $K_m$ and $V_{max}$ measured by competitive spectrophotometry are almost the same as those values measured by semi-classical method. Colorimetric Ellman's assays showed the thio-peptido mimetics to be a suitable substrates for trypsin. Kinetic studies with trypsin gave $K_m$ of 2.33 mM and $k_{cat}$ of $1.50{\times}10^5\;min^{-1}$ for carboxy-alanyl-thiaarginine benzyl ester and $K_m$ of $3.41{\times}10^{-3}\; Mm\; and\; k_{cat}\; of\; 520{\times}102\; min^{-1}$ for carbobenzoxy-alanyl-thialysine benzyl ester, respectively. Kinetic constants $(K_m=2.04{\times}10^{-2}\; mM, K_{cat}=4.42{\times}10^3 \;min^{-1})$ for natural substrate, carbobenzoxy-alanyl-lysine benzyl ester, were also evaluated by competitive spectrophotometry in order to compare the mode of binding on trypsin.

분광광도계를 이용한 점토함량 분석 (Use of Spectrophotometry for Quantitative Determination of Soil Clay Content)

  • 박순남;김계훈;강지영
    • Applied Biological Chemistry
    • /
    • 제48권2호
    • /
    • pp.183-188
    • /
    • 2005
  • 토양 입경분석 중 점토함량 분석과정은 특히 시간과 공간을 많이 필요로 한다. 본 연구는 분광광도계(spectrophotometer)를 이용하여 점토함량을 측정하는 방법을 개발하고자 수행되었다. 분광광도계를 이용한 점토함량 분석방법은 다음의 4단계를 통해 개발되었다. 첫째, 분광광도계로 점토 분석이 가능한 최적파장을 선택하기 위해 표준 점토 시료(kaolinite, vermiculite, illite, montmorillonite)를 이용하여 점토종류에 따른 파장별 흡광도를 측정하였으며, 최적 파장으로 500 nm를 선정하였다. 둘째, 분광광도계를 이용한 재현성이 높은 분석 방법은 250 ml 삼각 플라스크에 풍건 토양과 분산액을 넣고 12시간 진탕(130 rpm)하여 토양시료를 분산시킨 후 용기를 30초간 상하로 흔들어 미리 설치한 cell에 4 ml를 피펫으로 취하여 즉시 흡광도를 측정하는 것으로 조사되었다. 셋째, 점토함량 정량 분석을 위해 검정선(calibration curve)을 작성하였다. 넷째, 분광광도법(spectrophotometry)으로 분석된 동일 시료의 점토함량을 표준 방법으로 알려진 피펫법(pipet method)으로 분석한 후 회귀분석을 실시하여 분광광도법으로 측정한 점토함량을 피펫법으로 분석한 결과로 환산하는 환산식을 유도하였다. 분광광도법으로 측정한 점토함량은 토양시료내에 포함된 유기물 함량과도 상관관계가 조사되어 피펫법으로 측정한 점토함량과 분광광도법으로 측정한 점토함량, 유기물 함량간의 다중 회귀분석을 실시하였다. 그 결과 회귀방정식은 $y\;=\;38.03x_1-0.17x_2-1.17$(y = 피펫법으로 측정한 점토함량(%); $x_1$ = 분광광도법으로 측정한 점토함량(%); $x_2$ = 유기물 함량($g{\cdot}kg^{-1})$)이었으며, 상관계수는 $0.984^{**}$로 두 방법사이에 높은 상관관계가 있는 것으로 조사되었다. 여기서 유도된 회귀방정식을 프로그램화하여 컴퓨터나 분석기기에 입력시 시간과 공간을 절약하고 신속하고 정확하게 점토함량을 분석할 수 있을 것으로 판단된다.