• 제목/요약/키워드: spectrometry (ICP-MS)

검색결과 174건 처리시간 0.03초

유도결합 플라즈마 질량분석기를 이용한 동물사료중의 극미량원소의 분석 (Determination of Trace Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry)

  • 박정화;김효진
    • 약학회지
    • /
    • 제36권3호
    • /
    • pp.199-204
    • /
    • 1992
  • The trace elements in animal feed were analyzed by Inductively Coupled Plasma Mass Spectrometer (ICP-MS, VG-PlasmaQuad Co.) to find possible sources of heavy metals accumulation in rat organ. The study about spectral interference was performed by analysis of a background spectrum of ICP-MS. Recovery test using standard of Cd and Se (100 ppb) was found to be better than 90%. Twenty elements (Ca, Fe, Mg, Ti, Cr, Ni, Cu, Zn, Ba, Al, Mn, Pb, B, Ce, Bi, U, V, Cd, and W)are determined.

  • PDF

Accurate Analysis of Chromium in Foodstuffs by Using Inductively Coupled Plasma Mass Spectrometry with a Collision-Reaction Interface

  • Lee, Seung Ha;Kim, Ji Ae;Choi, Seung Hyeon;Kim, Young Soon;Choi, Dal Woong
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권6호
    • /
    • pp.1689-1692
    • /
    • 2013
  • Food is a common source of chromium (Cr) exposure. However, it is difficult to analyze Cr in complex food matrices by using inductively coupled plasma mass spectrometry (ICP-MS) because the major isotope, $^{52}Cr$, is masked by interference generated by the sample matrix and the plasma gas. Among the systems available to minimize interference, the recently developed collision-reaction interface (CRI) has a different structure relative to that of other systems (e.g., collision cell technology, octopole reaction system, and dynamic reaction cell) that were designed as a chamber between the skimmer cone and quadrupole. The CRI system introduces collision or reaction gas directly into the plasma region through a modified hole of skimmer cone. We evaluated the use of an CRI ICP-MS system to minimize polyatomic interference of $^{52}Cr$ and $^{53}Cr$ in various foodstuffs. The $^{52}Cr$ concentrations measured in the standard mode were 2-3 times higher than the certified values. This analytical method based on an ICP-MS system equipped with a CRI of helium gas was effective for Cr analysis in complex food matrices.

유도결합플라스마 질량분석을 위한 사용후핵연료 중 테크네튬-99의 추출크로마토그래피 분리 (Extraction Chromatographic Separation of Technetium-99 from Spent Nuclear Fuels for Its Determination by Inductively Coupled Plasma-Mass Spectrometry)

  • 서무열;이창헌;한선호;박영재;지광용;김원호
    • 분석과학
    • /
    • 제17권5호
    • /
    • pp.438-442
    • /
    • 2004
  • To determine the contents of $^{99}Tc$ in the spent PWR (pressurized water reactor) nuclear fuels by ICP-MS (inductively coupled plasma-mass spectrometry), a technetium separation method using an extraction chromatographic resin (TEVA Spec resin) has been established. $^{99}Tc$ was separated from a spent PWR nuclear fuel solution by this separation procedure and its concentration was determined by ICP-MS. The result agrees well with the value calculated by the program ORIGEN 2 and also the value measured by AG MP-1 resin/ICP-MS method described in our previous paper. It can be concluded that the present separation procedure is superior to the AG MP-1 resin procedure with respect to the time required for technetium separation as well as the efficiency of decontamination from other radioactive nuclides.

유도결합 플라스마 질량 분석법(ICP-MS)을 이용한 음용수 중의 전체 비소의 정량 (Determination of Total Arsenic in Drinking Water by Inductively Coupled Plasma-Mass Spectrometry)

  • 임유리;박경수;윤양희;김선태;정진호
    • 분석과학
    • /
    • 제13권4호
    • /
    • pp.423-427
    • /
    • 2000
  • 유도결합 플라스마 질량 분석법(ICP-MS)을 이용하여 음용수 중의 전체비소를 정량하였다. 지하수 및 간이 상수도와 시판되는 먹는 물에 질산을 첨가하여 1%로 산성화한 후에 ICP-MS로 전제비소의 함량을 분석하였다. 그 결과 음용수 중의 전체 비소는 $30{\mu}g/L$ 이하로서 수질 기준치인 $50{\mu}g/L$ 이하의 값을 나타내었다.

  • PDF

수소화물 생성-유도결합플라스마 원자방출분광법을 이용한 모의사용후 핵연료 중의 텔루르 분석 (Direct Determination of Tellurium in Simulated Nuclear Spent Fuels by Hydride Generation-Inductively Coupled Plasma Atomic Emission Spectrometry)

  • 최광순;이창헌;한선호;조기수;김원호
    • 분석과학
    • /
    • 제13권6호
    • /
    • pp.781-788
    • /
    • 2000
  • 수소화물 생성-유도결합플라스마 원자방출분광법(HG-ICP-AES)을 이용하여 모의사용후 핵연료(SIMFUEL) 중의 텔루르를 정량하였다. 염산과 $NaBH_4$의 농도 및 주입속도와 같은 변수들을 최적과 한 다음 각각 우라늄, 팔라듐, 루테늄, 로듐 및 몰리브덴의 간섭 정도를 조사하였다. 이들 원소, 특히 팔라듐으로부터 간섭을 줄이기 위하여 가리움제로 thiourea를 사용하였다. 모의사용후 핵연료로부터 텔루르를 양이온 교환 크로마토그래피로 분리한 다음 각각 HG-ICP-AES와 유도결합플라스마 질량분석법(ICP-MS)으로 측정하였다. 우라늄 매트릭스로부터 텔루르를 분리하지 않고 바로 전자로 측정한 결과와 분리한 다음 측정한 값의 상대편차는 ICP-MS의 결과를 기준으로 5.6%와 -1.2%이었다.

  • PDF

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

  • Yim, Yong-Hyeon;Park, Ji-Youn;Han, Myung-Sub;Park, Mi-Kyung;Kim, Byung-Joo;Lim, Young-Ran;Hwang, Eui-Jin;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.440-446
    • /
    • 2005
  • A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

Validation of Bulk Analysis with Simulated Swipe Samples Containing Ultra-Trace Amounts of Uranium and Plutonium Using MC-ICP-MS

  • Lim, Sang Ho;Han, Sun-Ho;Park, Jong-Ho;Park, Ranhee;Lee, Min Young;Park, Jinkyu;Lee, Chi-Gyu;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • 제6권3호
    • /
    • pp.75-79
    • /
    • 2015
  • Suitable analytical procedures for the bulk analysis of ultra-trace amounts of uranium and plutonium have been developed using multi-collector inductively coupled mass spectrometry (MC-ICP-MS). The quantification and determination of the isotopic ratios of uranium and plutonium in three simulated swipe samples, a swipe blank, and a process blank were performed to validate the analytical performance. The analytical results for the simulated swipe samples were in good agreement with the certified values, based on the measurement quality goals for the analysis of bulk environmental samples recommended by the International Atomic Energy Agency (IAEA)

ICP-MS에 의한 지하수 중의 Germanium 분석에 관한 연구 (Determination of Germanium in Spring Waters by Inductively Coupled Plasma Mass Spectrometry)

  • 박경수;송승연;심의섭;김선태
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.120-124
    • /
    • 1998
  • 지하수 중의 극미량 germanium을 ICP-MS로 신속, 정확하게 분석할 수 있었으며 질량수 74를 분석하는 것이 가장 방해영향이 적음을 알 수 있었다. 지하수 중의 약 30%만이 $0.1{\mu}g/L$ 이상의 germanium을 함유하였고, 유기 germanium을 포함하는 지하수의 존재도 확인하였다.

  • PDF

Improvement of Measurement Precisions for Uranium Isotopes at Ultra Trace Levels by Modification of the Sample Introduction System in MC-ICP-MS

  • Park, Ranhee;Lim, Sang Ho;Han, Sun-Ho;Lee, Min Young;Park, Jinkyu;Lee, Chi-Gyu;Song, Kyuseok
    • Mass Spectrometry Letters
    • /
    • 제7권2호
    • /
    • pp.50-54
    • /
    • 2016
  • Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is currently used in our laboratory for isotopic and quantitative analyses of nuclear materials at ultra-trace levels in environmental swipe samples, which is a very useful for monitoring undeclared nuclear activities. In this study, to improve measurement precisions of uranium isotopes at ultratrace levels, we adopted a desolvating nebulizer system (Aridus-II, CETAC., USA), which can improve signal sensitivity and reduce formation of uranium hydride. A peristaltic pump was combined with Aridus-II in the sample introduction system of MC-ICP-MS to reduce long-term signal fluctuations by maintaining a constant flow rate of the sample solution. The signal sensitivity in the presence of Aridus-II was improved more than 10-fold and the formation ratio of UH/U decreased by 16- to 17- fold compared to a normal spray chamber. Long-term signal fluctuations were significantly reduced by using the peristaltic pump. Detailed optimizations and evaluations with uranium standards are also discussed in this paper.

Direct Analysis of Aerosol Particles by Atomic Emission and Mass Spectrometry

  • Kawaguchi, Hiroshi;Nomizu, Tsutomu;Tanaka, Tomokazu;Kaneco, Satoshi
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.411-418
    • /
    • 1995
  • A method for the direct determination of elemental content in each of aerosol particles by inductively coupled plasma atomic emission (ICP-AES) or mass spectrometry (ICP-MS) is described. This method is based upon the introduction of diluted aerosol into an ICP and the measurement of either the flash emission intensities of an atomic spectral line or ion intensities. A pulse-height analyzer is used for the measurement of the distribution of the elemental content. In order to calibrate the measuring system, monodisperse aerosols are used. The potentials of the method are shown by demonstrating the copper emission signals from the aerosols generated at a small electric switch, a study of the relation between the decreasing rate of particle number density and particle size, and measurements of calcium contents in the individual biological cells.

  • PDF