• 제목/요약/키워드: spectral matching measure

검색결과 8건 처리시간 0.014초

Noisy Band Removal Using Band Correlation in Hyperspectral lmages

  • Huan, Nguyen Van;Kim, Hak-Il
    • 대한원격탐사학회지
    • /
    • 제25권3호
    • /
    • pp.263-270
    • /
    • 2009
  • Noise band removal is a crucial step before spectral matching since the noise bands can distort the typical shape of spectral reflectance, leading to degradation on the matching results. This paper proposes a statistical noise band removal method for hyperspectral data using the correlation coefficient between two bands. The correlation coefficient measures the strength and direction of a linear relationship between two random variables. Considering each band of the hyperspectral data as a random variable, the correlation between two signal bands is high; existence of a noisy band will produce a low correlation due to ill-correlativeness and undirected ness. The unsupervised k-nearest neighbor clustering method is implemented in accordance with three well-accepted spectral matching measures, namely ED, SAM and SID in order to evaluate the validation of the proposed method. This paper also proposes a hierarchical scheme of combining those measures. Finally, a separability assessment based on the between-class and the within-class scatter matrices is followed to evaluate the applicability of the proposed noise band removal method. Also, the paper brings out a comparison for spectral matching measures. The experimental results conducted on a 228-band hyperspectral data show that while the SAM measure is rather resistant, the performance of SID measure is more sensitive to noise.

Identification Performance of Low-Molecular Compounds by Searching Tandem Mass Spectral Libraries with Simple Peak Matching

  • Milman, Boris L.;Zhurkovich, Inna K.
    • Mass Spectrometry Letters
    • /
    • 제9권3호
    • /
    • pp.73-76
    • /
    • 2018
  • The number of matched peaks (NMP) is estimated as the spectral similarity measure in tandem mass spectral library searches of small molecules. In the high resolution mode, NMP provides the same reliable identification as in the case of a common dot-product function. Corresponding true positive rates are ($94{\pm}3$) % and ($96{\pm}3$) %, respectively.

STATISTICAL NOISE BAND REMOVAL FOR SURFACE CLUSTERING OF HYPERSPECTRAL DATA

  • Huan, Nguyen Van;Kim, Hak-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.111-114
    • /
    • 2008
  • The existence of noise bands may deform the typical shape of the spectrum, making the accuracy of clustering degraded. This paper proposes a statistical approach to remove noise bands in hyperspectral data using the correlation coefficient of bands as an indicator. Considering each band as a random variable, two adjacent signal bands in hyperspectral data are highly correlative. On the contrary, existence of a noise band will produce a low correlation. For clustering, the unsupervised ${\kappa}$-nearest neighbor clustering method is implemented in accordance with three well-accepted spectral matching measures, namely ED, SAM and SID. Furthermore, this paper proposes a hierarchical scheme of combining those measures. Finally, a separability assessment based on the between-class and the within-class scatter matrices is followed to evaluate the applicability of the proposed noise band removal method. Also, the paper brings out a comparison for spectral matching measures.

  • PDF

Statistical Approach to Noisy Band Removal for Enhancement of HIRIS Image Classification

  • Huan, Nguyen Van;Kim, Hak-Il
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 춘계학술대회 논문집
    • /
    • pp.195-200
    • /
    • 2008
  • The accuracy of classifying pixels in HIRIS images is usually degraded by noisy bands since noisy bands may deform the typical shape of spectral reflectance. Proposed in this paper is a statistical method for noisy band removal which mainly makes use of the correlation coefficients between bands. Considering each band as a random variable, the correlation coefficient measures the strength and direction of a linear relationship between two random variables. While the correlation between two signal bands is high, existence of a noisy band will produce a low correlation due to ill-correlativeness and undirectedness. The application of the correlation coefficient as a measure for detecting noisy bands is under a two-pass screening scheme. This method is independent of the prior knowledge of the sensor or the cause resulted in the noise. The classification in this experiment uses the unsupervised k-nearest neighbor algorithm in accordance with the well-accepted Euclidean distance measure and the spectral angle mapper measure. This paper also proposes a hierarchical combination of these measures for spectral matching. Finally, a separability assessment based on the between-class and within-class scatter matrices is followed to evaluate the performance.

  • PDF

연결발화에서 마비말화자의 음질 특성 (Voice Quality of Dysarthric Speakers in Connected Speech)

  • 서인효;성철재
    • 말소리와 음성과학
    • /
    • 제5권4호
    • /
    • pp.33-41
    • /
    • 2013
  • This study investigated the perceptual and cepstral/spectral characteristics of phonation and their relationships in dysarthria in connected speech. Twenty-two participants were divided into two groups; the eleven dysarthric speakers were paired with matching age and gender healthy control participants. A perceptual evaluation was performed by three speech pathologists using the GRBAS scale to measure the cepstrual/spectral characteristics of phonation between the two groups' connected speech. Correlations showed dysarthric speakers scored significantly worse (with a higher rating) with severities in G (overall dysphonia grade), B (breathiness), and S (strain), while the smoothed prominence of the cepstral peak (CPPs) was significantly lower. The CPPs were significantly correlated with the perceptual ratings, including G, B, and S. The utility of CPPs is supported by its high relationship with perceptually rated dysphonia severity in dysarthric speakers. The receiver operating characteristic (ROC) analysis showed that the threshold of 5.08 dB for the CPPs achieved a good classification for dysarthria, with 63.6% sensitivity and the perfect specificity (100%). Those results indicate the CPPs reliably distinguished between healthy controls and dysarthric speakers. However, the CPP frequency (CPP F0) and low-high spectral ratio (L/H ratio) were not significantly different between the two groups.

A rapid screening method for selection and modification of ground motions for time history analysis

  • Behnamfar, Farhad;Velni, Mehdi Talebi
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.29-39
    • /
    • 2019
  • A three-step screening process is presented in this article for selection of consistent earthquake records in which number of suitable ground motions is quickly screened and reduced to a handful number. Records that remain at the end of this screening process considerably reduce the dispersion of structural responses. Then, an effective method is presented for spectral matching and modification of the selected records. Dispersion of structural responses is explored using different statistical measures for each scaling procedure. It is shown that the Uniform Design Method, presented in this study for scaling of earthquake records, results in most cases in the least dispersion measure.

Efficient damage assessment for selected earthquake records based on spectral matching

  • Strukar, Kristina;Sipos, Tanja Kalman;Jelec, Mario;Hadzima-Nyarko, Marijana
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.271-282
    • /
    • 2019
  • Knowing the response of buildings to earthquakes is very important in order to ensure that a structure is able to withstand a given level of ground shaking. Thus, nonlinear dynamic earthquake engineering analyses are unavoidable and are preferable procedure in the seismic assessment of buildings. In order to estimate seismic performance on the basis of the hazard at the site where the structure is located, the selection of appropriate seismic input is known to be a critical step while performing this kind of analysis. In this paper, seismic analysis is performed for a four-story reinforced concrete ISPRA frame structure which is designed according to Eurocode 8 (EC8). A total of 90 different earthquake scenarios were selected, 30 for each of three target spectrums, EC8 spectrum, Uniform Hazard Spectrum (UHS), and Conditional Mean Spectrum (CMS). The aim of this analysis was to evaluate the average maximum Inter-story Drift Ratio (IDR) for each target spectrum. Time history analysis for every earthquake record was obtained and, as a result, IDR as the main measure of damage were presented in order to compare with defined performance levels of reinforced concrete bare frames.

Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios

  • Mazza, Fabio;Mazza, Mirko
    • Earthquakes and Structures
    • /
    • 제13권3호
    • /
    • pp.267-277
    • /
    • 2017
  • Base-isolation is now being adopted as a retrofitting strategy to improve seismic behaviour of reinforced concrete (r.c.) framed structures subjected to far-fault earthquakes. However, the increase in deformability of a base-isolated framed building may lead to amplification in the structural response under the long-duration horizontal pulses of high-magnitude near-fault earthquakes, which can become critical once the strength level of a fire-weakened r.c. superstructure is reduced. The aim of the present work is to investigate the nonlinear seismic response of fire-damaged r.c. framed structures retrofitted by base-isolation. For this purpose, a five-storey r.c. framed building primarily designed (as fixed-base) in compliance with a former Italian seismic code for a medium-risk zone, is to be retrofitted by the insertion of elastomeric bearings to meet the requirements of the current Italian code in a high-risk seismic zone. The nonlinear seismic response of the original (fixed-base) and retrofitted (base-isolated) test structures in a no fire situation are compared with those in the event of fire in the superstructure, where parametric temperature-time curves are defined at the first level, the first two and the upper levels. A lumped plasticity model describes the inelastic behaviour of the fire-damaged r.c. frame members, while a nonlinear force-displacement law is adopted for the elastomeric bearings. The average root-mean-square deviation of the observed spectrum from the target design spectrum together with a suitable intensity measure are chosen to select and scale near- and far-fault earthquakes on the basis of the design hypotheses adopted.