• Title/Summary/Keyword: specimens size

Search Result 1,774, Processing Time 0.024 seconds

Size Effect on Axial Compressive Strength of Notched Concrete Specimens (노치가 있는 콘크리트 실험체의 축압축 강도에 대한 크기효과)

  • 이성태;김봉준;김진근
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.99-108
    • /
    • 2000
  • The size effect on axial compressive strength in notched concrete specimens was experimentally investigated. Based on the concept of the fracture mechanics and size effect law, theoretical studies for axial compressive failure of concrete were reviewed, and two failure modes of concrete specimens under compression were discussed. In this study, experiments of axial compressive failure, which is one of the two failure modes, was carried out by using cylindrical specimens. Adequate notch length was taken from the experimental result of strength variation based on the notch length. And, by taking various sizes of specimens the size effect on axial compressive strength of concrete was investigated. Also, model equations were suggested by modified size effect law (MSEL). The test results show that size effect appears conspicuously for all series of specimens. Additionally, the effect of initial notch length on axial compressive strength was also apparent.

Influences of Grain Size on some Properties of the Penferroelectric PLZT Ceramics (준강유전 PLZT 세라믹의 그레인 크기 변화에 따른 특성연구)

  • Park, Chang-Yub;Yoo, Jo-Hyn;Park, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.213-215
    • /
    • 1987
  • In this paper, influences or grain size on the electro-optic properties were studied on the penferroelectric PLZT ceramics. The specimens were fabricated by the two stage sintering method. Relative permittivity was a little increased with the increment or grain size in 9,9.5/65/35 (La/Zr/Ti) PLZT specimens, and Curie temperature was decreased in the 9.5/65/35 specimens but constant in the 9.5/65/35 specimens. As the grain size was increased, field induced polarization and dP/dE were increased. Because domain walls can be easily moved by electric field. Light transmittance was increased in the 9/65/35 PLZT specimens but there was little effect on the grain size in the 9.5/65/35 PLZT specimens.

  • PDF

Size Effect of Axial Compressive Strength of Concrte in Notched Specimens (노치가 있는 콘크리트 공시체의 축압축강도에 대한 크기효과)

  • 김민욱;김진근;김봉준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.135-140
    • /
    • 1999
  • The size effect of axial compressive strength of concrete in notched specimens was experimentally investigated. Based on the concept of the fracture mechanics and size effect law, theoretical studies for axial compressive failure of concrete were reviewed, and two failure modes of concrete specimen under compression were discussed. In this study, experiment of axial compressive failure, which is one of the two failure modes, was carried out by using double cantilever fracture specimens. By varying the slenderness of cantilevers and the eccentricity of applied loads with respect to the axis of each cantilever, the size effect of axial compressive strength of concrete was investigated, and predicted by Bazant's size effect law. The test results show that size effect appears conspicuously for all series of specimens. For the eccentricity of loads, the influence of tensile and compressive stress at the notch tip are significant and so that the size effect is varied. In other words, if the influence of tensile stress at the notch tip grows up, the size effect of concrete increases. And the fact that the fracture process zone must be sufficiently secured for more accurate experiment was affirmed.

  • PDF

Size Effect of Axial Compressive Strength of CFRP Confined Concrete Cylinders

  • Akogbe, Romuald-Kokou;Liang, Meng;Wu, Zhi-Min
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • The main objective of this investigation is to study size effect on compressive strength of CFRP confined concrete cylinders subjected to axial compressive loading. In total 24 concrete cylinders with different sizes were tested, small specimens with a diameter of 100 mm and a height of 200 mm, medium specimens with a diameter of 200 mm and a height of 400 mm, and big specimens with a diameter of 300 mm and a height of 600 mm. The lateral confining pressure of each specimen is the same and from that hypothesis the small specimens were confined with one layer of CFRP, medium and big specimens were performed by two and three layers of CFRP respectively. Test results indicate a significant enhancement in compressive strength for all confined specimens, and moreover, the compressive strengths of small and medium specimens are almost the same while a bit lower for big specimens. These results permit to conclude that there is no size effect on compressive strength of confined specimens regardless of cylinder dimension.

Size Effect for Flexural Compression of Concrete Specimens (휨.압축 하중을 받는 콘크리트 부재의 크기효과)

  • 김진근;이성태;양은익;김민욱;이상순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.371-376
    • /
    • 1998
  • In this study, the size effect of concrete members subjected to the axial load and bending moment is investigated using a series of C-shaped specimens of which test procedure is similar to those of Hognestad, Hanson, and McHenry's. Main test variable is a size ratio of the specimens(1:1/2:1/4) at the concrete compressive strength of 500kg/㎠. Test results show that the flexural compression strength at failure decreases as the size of specimen increases, that is, the size effect law is present. Model equation is derived using regression analyses with experimental data and it is compared with formulas for compressive strength of cylinders and shear strength of beams without stirrups. Size effects is distinct th following sequence; shear strength of beams without stirrups, compressive strength of C-shaped specimens, compressive strength of cylinders.

  • PDF

Size effect study on compressive strength of SCLC

  • Karamloo, Mohammad;Roudak, Mohammad Amin;Hosseinpour, Hamed
    • Computers and Concrete
    • /
    • v.23 no.6
    • /
    • pp.409-419
    • /
    • 2019
  • In the present study, effect of size and placement of cubic specimens on compressive strength of self-compacting lightweight concrete (SCLC) were considered. To do so, 81 specimens of different sizes (50 mm, 75 mm, 100 mm, and 150 mm) were prepared by using three different mixes of SCLC. Results of the cured specimens were then used in regression analyses to find predictive equations with regard to both the placement direction and the size. Test results showed that the strength ratio in cases in which the direction of loading and placement were parallel, were higher than those specimens, whose configurations were normal between loading and placement. In addition, strength ratios in SCLC mixes were slightly higher than those are for self-compacting normal weight concrete. In order to analyze the effect of size on compressive strength the conventional size effect law as well as the modified size effect law (MSEL) were used. Besides, the convergence criterion of nonlinear regression process of size effect study has been discussed. Analyses of the results showed that the unconstraint nonlinear regression in size effect study of SCLC mixes could lead to erroneous results.

Bond behavior investigation of ordinary concrete-rebar with hinged beam test and eccentric pull-out test

  • Arslan, Mehmet E.;Pul, Selim
    • Computers and Concrete
    • /
    • v.26 no.6
    • /
    • pp.587-593
    • /
    • 2020
  • In this study, bond behavior of ordinary concrete and rebars with different diameters and development length was investigated by using Hinged Beam Test (HBT) and Eccentric Pull-Out Test (EPT) comparatively. For this purpose, three different rebar size and development length depending on rebar diameter were chosen as variables. Three specimens were produced for each series of specimens and totally 54 specimens were tested. At the end of the tests it was observed that obtained results for both tests were quite similar. On the other hand, increased bar size, especially for the specimen with 14 mm bar size and 14 development length (lb), caused shear failure of test specimens. This situation infers that when bigger bar size and lb are used in such test, dimensions of test specimens should be chosen bigger and stirrups should be used for producing of test specimens to obtain more adequate result by preventing shear failure. Also, a nonlinear regression analysis was employed between HBT and EPT results. There was a high correlation between the EPT values, lb, rebar diameters and estimated theoretical HBT. In addition, at the end of the study an equation was suggested to estimate bond strength for HBT by using EPT results.

An efficient algorithm for scaling problem of notched beam specimens with various notch to depth ratios

  • Karamloo, Mohammad;Mazloom, Moosa
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.39-51
    • /
    • 2018
  • This study introduces a new algorithm to determine size independent values of fracture energy, fracture toughness, and fracture process zone length in three-point bending specimens with shallow to deep notches. By using the exact beam theory, a concept of equivalent notch length is introduced for specimens with no notches in order to predict the peak loads with acceptable precisions. Moreover, the method considers the variations of fracture process zone length and effects of higher order terms of stress field in each specimen size. In this paper, it was demonstrated that the use of some recently developed size effect laws raises some concerns due to the use of nonlinear regression analysis. By using a comprehensive fracture test data, provided by Hoover and Bazant, the algorithm has been assessed. It could be concluded that the proposed algorithm can facilitate a powerful tool for size effect study of three-point bending specimens with different notch lengths.

Size Effect on Axial Compressive Strength of Notched Concrete Specimens

  • Yi, Seong-Tae;Kim, Jin-Keun
    • KCI Concrete Journal
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2002
  • In this study, size effect tests were conducted on axial compressive strength of concrete members. An experiment of Mode I failure, which is one of two representative compressive failure modes, was carried out by using dimensionally proportional cylindrical specimens (CS). An adequate notch length was taken from the experimental results obtained from the compressive strength experiment of various initial notch lengths. Utilizing the notch length, specimen sizes were then varied. In addition, new parameters for the modified size effect law (MSEL) were suggested using Levenberg-Marquardt's least square method (LSM). The test results show that size effect was apparent for axial compressive strength of cracked specimens. Namely, the effect of initial notch length on axial compressive strength size effect was apparent.

  • PDF

Aspects of size effect on discrete element modeling of normal strength concrete

  • Gyurko, Zoltan;Nemes, Rita
    • Computers and Concrete
    • /
    • v.28 no.5
    • /
    • pp.521-532
    • /
    • 2021
  • Present paper focuses on the modeling of size effect on the compressive strength of normal concrete with the application of Discrete Element Method (DEM). Test specimens with different size and shape were cast and uniaxial compressive strength test was performed on each sample. Five different concrete mixes were used, all belonging to a different normal strength concrete class (C20/25, C30/37, C35/45, C45/55, and C50/60). The numerical simulations were carried out by using the PFC 5 software, which applies rigid spheres and contacts between them to model the material. DEM modeling of size effect could be advantageous because the development of micro-cracks in the material can be observed and the failure mode can be visualized. The series of experiments were repeated with the model after calibration. The relationship of the parallel bond strength of the contacts and the laboratory compressive strength test was analyzed by aiming to determine a relation between the compressive strength and the bond strength of different sized models. An equation was derived based on Bazant's size effect law to estimate the parallel bond strength of differently sized specimens. The parameters of the equation were optimized based on measurement data using nonlinear least-squares method with SSE (sum of squared errors) objective function. The laboratory test results showed a good agreement with the literature data (compressive strength is decreasing with the increase of the size of the specimen regardless of the shape). The derived estimation models showed strong correlation with the measurement data. The results indicated that the size effect is stronger on concretes with lower strength class due to the higher level of inhomogeneity of the material. It was observed that size effect is more significant on cube specimens than on cylinder samples, which can be caused by the side ratios of the specimens and the size of the purely compressed zone. A limit value for the minimum size of DE model for cubes and cylinder was determined, above which the size effect on compressive strength can be neglected within the investigated size range. The relationship of model size (particle number) and computational time was analyzed and a method to decrease the computational time (number of iterations) of material genesis is proposed.