• Title/Summary/Keyword: specified design strength

Search Result 195, Processing Time 0.026 seconds

Statistical Estimation of Specified Concrete Strength by Applying Non-Destructive Test Data (비파괴시험 자료를 적용한 콘크리트 기준강도의 통계적 추정)

  • Paik, Inyeol
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2015
  • The aim of the paper is to introduce the statistical definition of the specified compressive strength of the concrete to be used for safety evaluation of the existing structure in domestic practice and to present the practical method to obtain the specified strength by utilizing the non-destructive test data as well as the limited number of core test data. The statistical definition of the specified compressive strength of concrete in the design codes is reviewed and the consistent formulations to statistically estimate the specified strength for assessment are described. In order to prevent estimating an unrealistically small value of the specified strength due to limited number of data, it is proposed that the information from the non-destructive test data is combined to that of the minimum core test data. The the sample mean, standard deviation and total number of concrete test are obtained from combined test data. The proposed procedures are applied to an example test data composed of the artificial numerical values and the actual evaluation data collected from the bridge assessment reports. The calculation results show that the proposed statistical estimation procedures yield reasonable values of the specified strength for assessment by applying the non-destructive test data in addition to the limited number of core test data.

Properties of Medium Strength Self-Compacting Concrete with Simple Mix design Method (간편 배합설계방법을 통한 중간강도 자기충전 콘크리트의 특성)

  • 최연왕;조선규;최욱;김경환;안성일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.83-88
    • /
    • 2003
  • In this paper, the medium strength self-compacting concrete with simple mix design method was manufactured and investigated about the properties of flowability and strength. Two types of binders like as fly-ash and RP(rock powder) were contained to the SCC in order to obtain the target medium strength of 270-350kgf/$cm^2$. The experimental tests about slump-flow, reaching time to the slump-flow of 50cm, V-funnel and U-box were carried out in accordance with the specified by the Japanese Society of Civil Engineering(JSCE). The mechanical properties such as compressive strength, splitting tensile strength and static modulus of elasticity were checked with the requirements specified by KS.

  • PDF

Chloride Ion Diffusion Coefficient and Compressive Strength of the Concrete Produced by Ready Mixed Concrete Company in Busan (부산지역 레미콘사의 콘크리트의 압축강도와 염소이온 확산계수)

  • Park, Dong-Cheon;Bang, Jung-Suk;Kim, Yong-Ro;Lee, Tae-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.11-12
    • /
    • 2017
  • The properties of concrete produced by ready mixed concrete company in Busan were tested. Because the concrete was mixed with blast furnace slag and fly ash, the compressive strength and chloride ion diffusion coefficient were lower than OPC concrete even though the specified concrete strength was same. If the durability about salt attack were satisfied, the concrete of lower specified concrete strength would be adopted to concrete mixing design.

  • PDF

Period of the Strength Correction of the Concrete with the Temperature Level Based on Meteorological Data (기상자료를 이용한 콘크리트의 단계별 기온보정강도 적응기간 산정)

  • Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • According to Korean Architectural Standard Specification (KASS) , at the design stage of the specified concrete strength, strength correction with each temperature level should be considered to secure required strength at 28 days even in low temperature condition, In this paper, the period for the strength correction at the stage of mixture design of the concrete using ordinary Portland cement(OPC) specified in KASS was determined with each region of south Korea based on the meteorological data of KMA(Korea meteorological administration) by applying KASS-5 regulation. In case of 28 days of strength control age, the period for strength correction with 6MPa was calculated to $50{\sim}60$ days and, with 3 MPa. to around 80 days. The period for the strength correction was shown to be decreased with the rise of altitude. The period to consider the delay of the strength development due to low temperature including the period of cold weather concrete was nearly 7 months around 1 year. References for determining the strength correction factors with each region of south Korea was provided in this paper. Further investigation of strength correction of the concrete containing blended cement is to studied.

A Case Study of Placed Remicon in "S" Apartment (현장 콘크리트의 품질에 관한 소고)

  • 이학영;윤두순
    • Journal of the Korean Professional Engineers Association
    • /
    • v.30 no.6
    • /
    • pp.113-120
    • /
    • 1997
  • This subject,'S" apartment structural frame has not been achieved without considerable effort by all quality controller involved. Therefore, it is appropriate at this time to report by all the fact of concrete quality control in our site. These are emphasized that the average strength of placed concrete must always exceed the specified value of design strength used in the structural design phase. In general, quality of ready mixed concrete largely depends not only upon the manner of production and proper observance of recognized methods of placement, finishing, curing, transportation etc. ,but also many kinds of influential factors even more handling of the test procedure, As this practical report, approaching to judgement by analysis of sampled specimens in site weather placed concrete have satisfied quality compare the specified strength with the target strength which is applied to standard deviation related with influential factors as above mentioned. This case study is consist of 1) A foreword, 2) Site brief, 3) A precondition for analysis, 4) A formulas derivation and quality analysis, 5) Economic gains by the coefRcient of increase and 6) A conclusion.sion.

  • PDF

Development and Application of Unit Table Form using Euro Form for High-rise Building Construction (슬래그 혼입 콘크리트의 염소이온 차단성능)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.136-137
    • /
    • 2018
  • The properties of concrete produced by ready mixed concrete company in Busan were measured. Because the concrete was mixed with blast furnace slag and fly ash etc., the compressive, tensile strength and chloride ion diffusion coefficient were lower than OPC concrete even though the specified concrete strength was same. If the durability about salt attack were satisfied, the concrete of lower specified concrete strength would be adopted to concrete mixing design. FEM analysis was carried out to predict the life time expectancy.

  • PDF

The Chloride Ion Diffusivity of Ready-Mixed Concrete Depending on Specified Compressive Strength (레디믹스트 콘크리트의 설계기준 압축강도별 염소이온 확산특성)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.543-550
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforcing steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is higher than 35MPa in the concrete/building construction standard specification. Even though it has been proved that the concrete mixed with mineral admixture such as blast furnace slag and fly ash etc. have high strength and durability in previous researches, the beneficial informations are not applied to the codes. Ready-mixed concretes which usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC. For economical and reliable durability design, chloride ion diffusivity should be measured before applying to new building construction.

Proposal of Return Period and Basic Wind Speed Map to Estimate Wind Loads for Strength Design in Korea (강도설계용 풍하중 평가를 위한 재현기간과 기본풍속지도의 제안)

  • Ha, Young-Cheol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.29-40
    • /
    • 2018
  • Strength design wind loads for the wind resistance design of structures shall be evaluated by the product of wind loads calculated based on the basic wind speed with 100 years return period and the wind load factor 1.3 specified in the provisions of load combinations in Korean Building Code (KBC) 2016. It may be sure that the wind load factor 1.3 in KBC(2016) had not been determined by probabilistic method or empirical method using meteorological wind speed data in Korea. In this paper, wind load factors were evaluated by probabilistic method and empirical method. The annual maximum 10 minutes mean wind speed data at 69 meteorological stations during past 40 years from 1973 to 2012 were selected for this evaluation. From the comparison of the results of those two method, it can be found that the mean values of wind load factors calculated both probability based method and empirical based method were similar at all meteorological stations. When target level of reliability index is set up 2.5, the mean value of wind load factors for all regions should be presented about 1.35. When target level of reliability index is set up 3.0, wind load factor should be presented about 1.46. By using the relationship between importance factor(conversion factor for return period) and wind load factor, the return periods for strength design were estimated and expected wind speeds of all regions accounting for strength design were proposed. It can be found that return period to estimate wind loads for strength design should be 500 years and 800 years in according to target level of reliability index 2.5 and 3.0, respectively. The 500 years basic wind speed map for strength design was suggested and it can be used with a wind load factor 1.0.

The Analysis of Internal & External Stabilities and Factors for D.C.M Design (DCM 설계에서 주요 인자의 결정과 내.외적 안정해석)

  • Lee, Choong-Ho;Jung, Seung-Yong;Han, Sang-Jae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.793-808
    • /
    • 2009
  • This paper presents procedure and prediction method of internal and external stabilities when designing D.C.M, with main factors to be considered, such as chemical reaction of additive, physical properties of stabilized body and mixing strength. Results show that through case studies, a design unconfined compressive strength of stabilized body (hereafter referred to as 'compressive strength') directly depends on the quantity of cement, which is decided by laboratory test, and the compressive strength enormously affects internal and external stabilities. So laboratory mixing test to obtain the compressive strength for design allowable stress should be given careful considerations.

  • PDF