• 제목/요약/키워드: specific heat coefficient

검색결과 117건 처리시간 0.039초

물성치 모델개발을 통한 고강도콘크리트의 시간의존 해석 (Time-dependent Analysis of High Strength Concrete Using Material Characteristics Model)

  • 이태규;김혜욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1096-1101
    • /
    • 2008
  • Concrete is shown the time dependent behavior after placing. The time dependent behavior of normal strength concrete that is used usually in present, were already examined closely lots of parameters by several investigators. however, high strength concrete is that the material characteristics are not definite and the experimental data are lacking. So, The goal of this study is to propose the material characteristics models, and to develop the routine of the time dependent behavior above 60 MPa. The thermal conductivity, the specific heat, the moisture diffusion coefficient, and the surface coefficient are proposed the suitable models through the parametric study. The structural element is used the 8-node solid element. The matrix equation is developed considering the transient heat transfer and moisture diffusion theory. The application of the time dependent behavior is used the finite differential method.

  • PDF

A Convective Heat Transfer Correlation for Turbulent Gas-Liquid Two-Phase Flow in Vertical Pipes

  • Kim, Dong-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.27-36
    • /
    • 2001
  • A new two-phase non-boiling convective heat transfer correlation for turbulent flow $(Re_{SL}>4000)$ in vertical tubes with different fluid flow patterns and fluid combinations was developed using experimental data available from the literature. The correlation presented herein originates from a careful analysis of the major non-dimensional parameters affecting two-phase heat transfer. This model takes into account the appropriate contributions of both the liquid and gas phases using the respective cross-sectional areas occupied by the two phases. A total of 255 data points from three available studies (which included the four sets of data) were used to determine the curve-fitted constants in the improved correlation. The performance of the new correlation was compared with two-phase correlations from the literature, which were developed for specific fluid combinations.

  • PDF

마이크로 캡슐 잠열재 슬러리를 적용한 미소채널 열교환기의 열분배 성능평가 (Experimental Study on the Heat Distribution in the Rectangular Mini Channel Heat Exchangers with MPCM Slurry)

  • 전종욱;백창현;김용찬;김영득;최종민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.645-650
    • /
    • 2006
  • The heat transfer performance and energy transport ability are relatively high due to higher specific heat. Therefore, it can be used in fields such as heating, ventilating, air-conditioning, refrigeration and heat exchangers. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, liquid-cooling heat exchangers were tested to provide performance data for MPCM slurry. The liquid-cooling heat exchangers had twelve rectangular channels with flow paths of 1, 2, 4 and 12. Silicon rubber heaters were used to control the heat load to the heat exchanger. Heat input ranged from 293 to 800 W, and inlet temperatures of working fluid varied from 15S to $27^{\circ}C$. The standard deviation of surface temperature was strongly affected by the coolant of MPCM Slurry, All MPCM-cooling heat exchangers showed higher cooling performance than the water-cooling heat exchanger except one path channel heat exchanger.

  • PDF

생체재료용 Ti-10Ta-10Nb 합금의 열적 특성 고찰 (Study on the thermal-property of Ti-10Ta-10Nb)

  • 반재삼;이경원;정상원;유영선;조규종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1370-1373
    • /
    • 2003
  • Specimens of Ti-10Ta-10Nb have been tested for Rockwall hardness after heating to either the $\alpha$+$\beta$ and $\beta$-phase field. And the specific heat and the dilatometer of Ti-10Ta-103Nb swaged have been measured. From the result, the $\beta$ transus of the alloy was determined to be 82$0^{\circ}C$. The hot deformation behavior of Ti-10Ta-10Nb with an $\alpha$+$\beta$ microstructure is modeled in the temperature 75$0^{\circ}C$ and strain rate range 0.001-10$^{-1}$

  • PDF

채널이 수막으로 완전히 덮여 있는 증발식 냉각기에서의 열 및 물질전달 해석 (Analysis of Heat and Mass Transfer in an Evaporative Cooler with Fully Wetted Channel)

  • 송찬호;이대영;노승탁
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1766-1775
    • /
    • 2001
  • A theoretical analysis on the heat and mass transfer in an evaporative cooler is presented in this work. The evaporative cooler is modeled as a channel filled with porous media the interstitial surface of which is covered by thin water film. Assuming that the Lewis number is unity and the water vapor saturation curve is linear, exact solutions to the energy and vapor concentration equations are obtained. Based on the exact solutions, the characteristics of the heat and mass transfer in the evaporative cooler are investigated. The comparison of the cooling performance between the evaporative cooler and the usual sensible heat exchanger is also carried out. Obviously, the evaporative heat exchanger shows better cooling performance than the sensible heat exchanger. This is due to the latent heat of water vaporization, which results in apparent increases both in the interstitial heat transfer coefficient and the specific heat of the air stream in the evaporative cooler.

A Study on the Improvement of Heat Transfer Performance in Low Temperature Closed Thermosyphon

  • Han, Kyu-Il;Yee, Seok-Su;Park, Sung-Hyun;Lee, Suk-Ho;Cho, Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제16권9호
    • /
    • pp.1102-1111
    • /
    • 2002
  • The study focuses on the heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal grooves. Three different working fluids(distilled water, methanol, ethanol) are used with various volumetric liquid fill charge ratio from 10 to 40%. Additional experimental parameters such as operating temperature and inclination angle of zero to 90 degrees are used for the comparison of heat transfer performance of the thermosyphon. Condensation and boiling heat transfer coefficients, heat flux are obtained using experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, liquid fill charge ratio, number of grooves and inclination angle are very important factors for the operation of thermosyphons. The relatively high rate of heat transfer is achieved when the thermosyphon with internal grooves is used compared to that with plain tube. The optimum liquid fill charge ratio for the best heat transfer performance lies between 25% and 30%. The range of the optimum inclination angle for this study is 20$^{\circ}$~30$^{\circ}$ from the horizontal position.

멀티형 인버터 열펌프의 냉방성능해석에 관한 연구 (Performance Analysis of a Multi-type Inverter Heat Pump)

  • 김영철;박근우;윤영;민만기;최영돈
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.153-159
    • /
    • 2001
  • A system simulation program was developed for a multi-type inverter heat pump. Electronic expansion valve(EEV) was used to extend the capacity modulating range of the heat pump as expansion device. The program was also developed to calculate actual system performance with the building load variation with climate during a year. The performance variation of a multi-type hat pump with two EEV and an inverter compressor was simulated with compressor speed, capacity, and flow area of the EEV. As a result, the optimum operating frequency of the compressor and openings of the expansion device were decided at a given load. As compressor speed increased, he capacity of heat pump increased, the capacity of heat pump increased. Therefore flow area of EEV should be adjusted to have wide openness. Thus the coefficient of performance(COP) of the heat pump decreased due to increasement of compressor power input. The maximum COP point at a given load was decided according to the compressor speed. And under the given specific compressor speed and the load, the optimum openings point of EEV was also decided. Although the total load of indoor units was constant, the operating frequency increased as the fraction of load in a room increased. Finally ad the compressor power input increased, the coefficient of performance decreased.

  • PDF

열손실량 보정을 통한 콘크리트 단열온도상승량 예측 장치 (Equipment for Measuring the Adiabatic Temperature Rise of Concrete by Compensating Heat Loss)

  • 진은웅;김진용;김진근
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.535-542
    • /
    • 2012
  • 매스 콘크리트에서 발생하는 수화열을 예측하기 위한 단열온도상승시험은 시험 비용이 고가이고 시공간상 제약으로 인해 한계가 있는 실정이다. 이에 신속하고 경제적이며 간편한 간이 수화열 측정 장치의 개발이 필요한 실정이다. 이 연구에서는 간이 수화열 측정 장치를 완성하기 전 단열 성능이 뛰어난 보온병에 콘크리트를 타설하고 열손실량을 보정하여, 간이 수화열 측정 장치의 타당성을 입증하고자 하였다. 열손실량을 정확히 예측하기 위해서는 측정 장치의 정확한 열손실계수를 추정하는 것이 필수적인데, 열손실계수는 단열 장치 내부의 수온 변화를 이용하여 추정하였다. 시험 결과 장치 고유의 열손실계수는 외부 온도와 습도, 내부 온도 변화에 크게 변하지 않는 것으로 드러났다. 실제 단열온도상승시험과 열손실량이 보정된 보온병의 단열온도상승량과의 검증 시험을 통해 이 연구의 객관성과 타당성을 입증할 수 있었다.

인터쿨러용 판형열교환기 내부유로의 유동현상에 관한 전산유체해석 (CFD Analysis for the Flow Phenomena of the Narrow Channels in Plate Heat Exchanger for Intercooler)

  • 윤천석;한승한
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.91-100
    • /
    • 2004
  • Plate heat exchangers (PHE) have been widely used in different industrial applications, because of high heat transfer efficiency per unit volume. Basic study is performed for PHE to the application of intercooler in automobile. In order to understand the flow phenomena in the plate heat exchanger, a channel which was formed by the upper and lower plate in single plate was considered as calculation domains. Because chevrons attached on the upper plate are brazed with chevrons attached on the lower plate, the flow channel has very complex configuration. This complex geometry was analyzed by Fluent. In order to validate this methodology the proper experimental and theoretical data are collected and compared with numerical results. Finally, due to the lack of experimental values for PHE to the application of intercooler, various chevron angles and air velocities at inlet were tested in terms of physical phenomena. From this point of view, results of velocity vector, path lines, static pressure, heat flux, heat transfer coefficient, and Nusselt number are physically reasonable and accepted for the solutions. From these results, the correlations for pressure drop and Nusselt number with respect to chevron angle and Reynolds number in specific PHE are obtained for the design purpose. Thus, the methodology of the flow analysis in the full geometry of the channel was established for the predictions of performance in plate heat exchanger.

위성과 부이자료를 이용한 현.잠열 추정에 관한 연구 (Estimation of Sensible and Latent Heat Fluxes Using the Satellite and Buoy Data)

  • 홍기만;김영섭;윤홍주;박경원
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2001년도 춘계 학술대회 논문집 통권 4호 Proceedings of the 2001 KSRS Spring Meeting
    • /
    • pp.104-110
    • /
    • 2001
  • Ocean heat fluxes over a wide region are generally estimated by an aerodynamic bulk fromula. Though a remote sensing technique can be expected to estimated global heat flux, it is difficult to obtain air temperature and specific humidity at sea surface by a remote sensor. In this study present a new method with which to determine near-sea surface air temperature from in situ data. Also, These methods compared with other methods. A new method used a linear regression equation between sea surface temperature and air temperature of the buoys data. In this study new method is validated using observed monthly mean data at the Japan Meteorological Agency(JMA), National Data Buoy Center(NDBC) and Tropical Ocean-Global Atmosphere(TOGA)-Tropical Atmosphere Ocean(TAO) buoys. The result that bias and rmse are 0.28, 1.5$0^{\circ}C$ respectively. The correlation coefficient is 0.98. Also, to retrieve near-sea surface specific humidity(Q) from good nonlinear regression relationship between vapor pressure(Ea) of buoy data and air temperature, after obtained the third-order polynomial function, compared with that of estimated from SSM/I empirical equation by Schussel et al(1995). The result that bias and rmse are -1.42 and 1.75(g/kg).

  • PDF