• 제목/요약/키워드: specific gravity (SG)

검색결과 26건 처리시간 0.022초

Nail Withdrawal Behavior for Domestic Small Diameter Logs

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.104-108
    • /
    • 2002
  • Nail withdrawal tests were conducted on clear wood of domestic small diameter logs. Nails were driven into the cross and longitudinal sections of each specimen, then nail withdrawal tests were performed. Nail withdrawal loads are strongly dependent on the direction of nail positions. The average load values for the nail withdrawal both in cross section and longitudinal section are higher in high specific gravity (SG) wood of sawtooth oak (Quercus acutissima Carr.) than those in low SG wood of Korean red pine (Pinus densiflora Sieb. et Zucc.) and pitch pine (Pinus rigida Mill.). The average ratio of the nail withdrawal loads for side-grain and end-grain are higher in the low SG wood than that in the high SG of wood. Both linear and non-linear regression analyses were conducted on nail withdrawal load with SG, good correlations were obtained between nail withdrawal load and SG.

Specific Gravity and Dimensional Stability of Boron-Densified Wood on Three Lesser-Used Species from Indonesia

  • AUGUSTINA, Sarah;WAHYUDI, Imam;DARMAWAN, I Wayan;MALIK, Jamaludin;BASRI, Efrida;KOJIMA, Yoichi
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.458-471
    • /
    • 2020
  • Effect of pre-treatment and compression ratio on specific gravity (SG) and dimensional stability improvement of three lesser-used wood species from natural forest area of North Kalimantan Province, Indonesia had been investigated. Hot soaking at 80℃ for 3 hours within 2 and 5% of boron solution was applied as pre-treatment, while compression ratio applied was 20 and 40% from the initial thickness. Densification was conducted using hot pressing machine at 30 kg/㎠ of pressure and 160℃ of temperature for 15 minutes. Specific gravity was measured gravimetrically, while dimensional stability was evaluated through thickness swelling and water absorption as the indicator. Results show that SG of densified wood was influenced by wood species and compression ratio, but not by pre-treatment applied; while dimensional stability was influenced by wood species, compression ratio, and pre-treatment. Specific gravity and water absorption of densified wood was improved significantly. Specific gravity increased 28.86-63.03%, while water absorption decreased 12.80-15.89%. Thickness swelling of 20% densified wood was lower than that of 40% densified wood.

소아 단백뇨 검사에 있어서 요비중의 유용성 (Urine Specific Gravity as a Useful Tool for Screening Proteinuria in Children)

  • 김종화;유기환;홍영숙;이주원;김순겸
    • Childhood Kidney Diseases
    • /
    • 제4권1호
    • /
    • pp.1-5
    • /
    • 2000
  • 목 적 : 24시간 소변내 단백량을 예측하는데 있어 spot urine의 단백은 소변량에 따른 보정이 필요하여 spot urine의 protein/creatinine(P/Cr)비를 이용하여왔다. 하지만 크레아티닌 측정에 많은 시간과 비용이 소모되는 단점이 있고, 비중(specific gravity; SG)을 이용하여 creatinine(estimated creatinine; Cr-est)을 산출할 수 있다는 보고가 있어, 24시간 소변내 단백량을 예측하는데 P/Cr-est비의 유용성을 알아보고자 본 연구를 시행하였다. 방 법 : 1998년 3월부터 6월까지 고려대학교 의료원 구로병원 소아과에 내원한 환아 147명을 대상으로 spot urine에서 단백, creatinine과 비중을 측정하여 creatinine과 비중의 상관관계 및 그 관계식을 구하고 24시간 소변내 단백량과 비교하였다. 결 과 : 1) spot urine의 creatinine과 비중은 통계적으로 의의 있는 상관관계를 보였다(R=0.407, P<0.001, Cr=SG. x 4485.82-4482.87). 2) 24시간 소변내 단백량은 P/Cr비와 통계적으로 의의 있는 상관관계를 보였다(R=0.771, P<0.001, 24시간뇨중 단백=0.338 x (P/Cr) +667.885). 3) 24시간 소변내 단백 량은 P/Cr-est 비와 통계적으로 의의 있는 상관관계를 보였다. (R=0.723, P<0.001, 24시간뇨중 단백=0.354 x (P/Cr-est) +726.044) 결 론 : 소아단백뇨를 예측하는데 있어 spot urine의 비중으로 산출한 creatinine치를 이용하여 얻어진 P/Cr-est비가 선별검사로서 유용하게 사용될 수 있으리라 생각된다.

  • PDF

밀도계를 이용한 비추출식 냉동기유농도 측정에 관한 연구 (An investigation on the in si·tu measurement of the oil-concentration with densimeter)

  • 김상현;김창년;박영무
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.31-37
    • /
    • 1999
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method to measure the oil concentration is to extract the working mixture and then to measure the oil weight. However, it is Quite necessary to estimate oil concentration without any extraction of the working fluid. In this study a new method and working equation is presented as follows. It is based on the measurement of spedific gravity and temperature : $$C=a+b{\times}t+c{\times}t^2+(d+e{\times}t+f{\times}t^2){\times}SG$$ C is oil concentration, t is temperature($^{\circ}C$), SG is specific gravity of mixture and a~f is coefficients. The oil concentration ranges over 0~12 wt% and the temperature ranges over $20{\sim}50^{\circ}C$. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/POE oil oiquid mixtures.

  • PDF

요중 카드뮴과 비소의 보정방법 비교 : 요중 크레아티닌과 요비중 (A Comparison of the Adjustment Methods for Assessing Urinary Concentrations of Cadmium and Arsenic: Creatinine vs. Specific Gravity)

  • 김동경;송지원;박정덕;최병선
    • 한국환경보건학회지
    • /
    • 제37권6호
    • /
    • pp.450-459
    • /
    • 2011
  • Objectives: Biomarkers in urine are important in assessing exposures to environmental or occupational chemicals and for evaluateing renal function by exposure from these chemicals. Spot urine samples are needed to adjust the concentration of these biomarkers for variations in urine dilution. This study was conducted to evaluate the suitability of adjusting the urinary concentration of cadmium (uCd) and arsenic (uAs) by specific gravity (SG) and urine creatinine (uCr). Methods: We measured the concentrations of blood cadmium (bCd), uCd, uAs, uCr, SG and N-acetyl-${\beta}$-D-glucosaminidase (NAG) activity, which is a sensitive marker of tubular damage by low dose Cd exposure, in spot urine samples collected from 536 individuals. The value of uCd, uAs and NAG were adjusted by SG and uCr. Results: The uCr levels were affected by gender (p < 0.01) and muscle mass (p < 0.01), while SG levels were affected by gender (p < 0.05). Unadjusted uCd and uAs were correlated with SG (uCd: r = 0.365, p < 0.01; uAs: r = 0.488, p < 0.01), uCr (uCd: r = 0.399, p < 0.01; uAs: r = 0.484, p < 0.01). uCd and uAs adjusted by SG were still correlated with SG (uCd: r = 0.360, p < 0.01, uAs: r = 0.483, p < 0.01). uCd and uAs adjusted by uCr and modified uCr ($M_{Cr}$) led to a significant negative correlation with uCr (uCd: r = -0.367, p < 0.01; uAs: r = -0.319, p < 0.01) and $M_{Cr}$ (uCd: r = -0.292, p < 0.01; uAs: r = -0.206, p < 0.01). However, uCd and uAs adjusted by conventional SG ($C_{SG}$) were disappeared from these urinary dilution effects (uCd: r = -0.081; uAs: r = 0.077). Conclusions: $C_{SG}$ adjustment appears to be more appropriate for variations in cadmium and arsenic in spot urine.

An investigation on the in si.tu measurement of the oil-concentration

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.20-28
    • /
    • 2001
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method is to extract the working mixture and then to measure the oil weight. In this study, oil concentration is measured in si.tu way without any extraction of the working fluid. Based on the measurement, a working equation is presented as follows, C=a +b x t +c x $t^2$ +(d + e x t +f x $t^2$) x SG. C is oil concentration, t is temperature($^{\circ}C). SG Is specific gravity of mixture and a~f is coefficients The oil concentration ranges over 0~l2 wt% and the temperature ranges over 20~50$^{\circ}C. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/P0E oil liquid mixtures.

  • PDF

An investigation on the in si.tu measurement of the oil-concentration

  • Kim, Chang-Nyeun;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.80-88
    • /
    • 2000
  • In order to predict thermodynamic performance of refrigeration system, it is required to know the oil concentration of the refrigerant/oil mixture. The current method is to extract the working mixture and then to measure the oil weight. In this study, oil concentration is measured in si.tu way without any extraction of the working fluid. Based on the measurement, a working equation is presented as follows, C=a +b x t +c x $t^2$ +(d + e x t +f x $t^2$) x SG. C is oil concentration, t is temperature($^{\circ}C). SG Is specific gravity of mixture and a~f is coefficients The oil concentration ranges over 0~l2 wt% and the temperature ranges over 20~50$^{\circ}C. The specific gravity and temperature are measured using the on-line densimeter and thermometer. This working equation enables to predict the oil concentration without any extraction of the mixture. This equation can be applied for R-12/Naphthenic oil and R-134a/P0E oil liquid mixtures.

  • PDF

Prediction of Carcass Fat, Protein, and Energy Content from Carcass Dry Matter and Specific Gravity of Broilers

  • Wiernusz, C.J.;Park, B.C.;Teeter, R.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권1호
    • /
    • pp.42-48
    • /
    • 1999
  • Three experiments were conducted to develop and test equations for predicting carcass composition. In the first study using 52 d-old Cobb ${\times}$ Cobb male broilers, twenty four carcasses were selected from 325 processed birds based upon visual appraisal for abdominal fat (low, medium, high) and assayed for specific gravity (SG), dry matter (DM), fat, protein, and ash. In experiment 2, 120 birds were fed rations containing 2 caloric densities (2,880 and $3,200kcal\;ME_n/kg$ diet) and assayed as described above on weeks 2,3,4,5, and 6. Carcass fat was elevated (p < 0.05) with increased caloric density. In both studies predictive variables were significantly correlated with chemically determined carcass fat, protein, and ash contents. Pooled across the 2 studies, data were used to form SG, DM, and or age based equations for predicting carcass composition. Results were tested in experiment 3, where 576 birds reared to 49-d consumed either 2,880, 3,200, or $3,574kcal\;ME_n/kg$ diet while exposed to constant $24^{\circ}C$ or cycling 24 to $35^{\circ}C$ ambient temperatures. Both dietary and environmental effects impacted (p < 0.05) carcass composition. The fat content analyzed chemically was enhanced from 12.4 to 15.7%, and predicted fat was also elevated from 13.4 to 14.8% with increasing caloric density. Heat distress reduced (p < 0.05) analyzed carcass protein (18.9 vs 18.3%) and predicted protein (18.2 vs 17.5%). Predicted equation values for carcass fat, protein, ash, and energy were correlated with the chemically analyzed values at r=0.96, 0.77, 0.86, and 0.79, respectively. Results suggest that prediction equations based on DM and SG may be used to estimate carcass fat, protein, ash, and energy contents of broilers consuming diets that differ in caloric density (2,800 to $3,574kcal\;ME_n/kg$) and for broilers exposed to either constant ($24^{\circ}C$) or cycling high (24 to $35^{\circ}C$) ambient temperatures during 49-d rearing period tested in the present study.

HPLC와 Jaffe method의 요중 크레아티닌 및 비중이 마뇨산 보정값에 미치는 요인에 관한 연구 (Effects of Factors Associated with Urine Hippuric Acid Correction Values in Urinary Creatinine by HPLC and Jaffe Method and Specific Gravity HPLC Jaffe Method)

  • 김기영;김종규;윤기남;박화미;박훈희
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.493-505
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate the relevance of adjusting a urinary sample for urine hippuric correction value and its effects. Urinary biological monitoring data are typically adjusted to a constant creatinine and specific gravity concentration to correct for variable dilutions among spot samples. This study was conducted to evaluate the suitability of adjusting the urinary concentrations of urine creatinine and specific gravity(SG). Methods: We measured the concentrations of hippuric acid, in spot urine samples collected from control(119), case(120) individuals. The value of hippuric acid was adjusted by SG and urinary creatinine(HPLC & Jaffe). Results: The major results were as follows. The concentrations of urinary creatinine and SG for the control group were 1.84 g/L(SD 0.99) for arithmetic mean and 1.56 g/L(GSD 1.86) for geometric mean by HPLC method, 1.57 g/L (SD, 0.82) for arithmetic mean and 1.33 g/L(GSD 1.85) for geometric mean by Jaffe method, 1.028(SD 0.09) for arithmetic mean and 1.02(GSD 1.06) for geometric mean by refractometer. Hippuric acid levels were 0.40 g/L(SD 0.51) by arithmetic mean and 0.20 g/L(GSD 3.59). In that case the exposed group was 1.40 g/L(SD 0.58) for arithmetic mean and 1.28 g/L(GSD 1.55) for geometric mean by HPLC method, 1.27 g/L(SD 0.56) for arithmetic mean and 1.14 g/L(GSD 1.62) for geometric mean by Jaffe method, 1.045 L(SD 0.27) for arithmetic mean and 1.02(GSD 1.13) for geometric mean by refractometer(P<0.05). Hippuric acid levels were 0.67 g/L(SD 0.79) for arithmetic mean and 0.39 g/L(GSD 2.94)(p<0.05). The urine creatinine concentrations were affected by gender(p < 0.01) but SG levels were not affected by gender or age(p>0.05). After adjustment, urine hippuric acid was correlated with creatinine(HPLC & Jaffe)(r=0.723, P<0.05, r=0.708, P<0.05) and SG(r=0.936, P<0.05) and the control group shows significantly higher than the case group. In the case group for adjusted urine hippuric acid was correlated with creatinine(HPLC & Jaffe), (r=0.736, P<0.05), r=0.549, P<0.05), SG(r=0.549, P<0.05). After adjusting urine hippuric acid by urine creatinine(HPLC and Jaffe method) and specific gravity, significant associations were found between the control group and case group, respectively(r=0.832, P<0.05, r=0.845, P<0.05) and (r=0.841, P<0.05, r=0.849, P<0.05). Specific gravity adjustment appears to be more appropriate for variations in the urine creatinine method. Conclusion: we found that urinary creatinine concentrations were significantly affected by gender, and other factors and that care should therefore be exercised when correcting urinary metabolites according to the urinary creatinine concentration in spot urine. It is determined that additional study is needed for biological monitoring.

국내에서 생산된 파티클보드의 나사못 유지력 예측 (Predicting the Screw Withdrawal Load of Commercial Particleboard Manufactured in Korea)

  • 차재경
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.544-550
    • /
    • 2013
  • 국내에서 생산된 파티클보드에 대한 나사못 유지력을 기존의 식으로부터 수정 보완된 예측 식으로 나타내기 위해 나사못 유지력실험을 실시했다. 본 연구에 사용된 나사못은 No. 6, No. 8 및 No. 10이었다. 나사못 유지력의 예측 식은 나사못의 직경과 관입길이, 파티클보드의 비중 및 IB의 함수로 나타냈다. 예측 식은 길이가 서로 다른 No. 8 나사못의 실험결과와 상당히 일치하였다. 파티클보드에 대한 실험결과들과 표면에서 나사못 유지력의 예측 값은 비중보다 IB가 더 좋은 예측인자였고, 측면에서는 IB보다 비중이 더 일치하였다.