• Title/Summary/Keyword: spacing effect

Search Result 828, Processing Time 0.023 seconds

Numerical Investigation on detonation combustion waves of hydrogen-air mixture in pulse detonation combustor with blockage

  • Pinku Debnath;K.M. Pandey
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.3
    • /
    • pp.203-222
    • /
    • 2023
  • The detonation combustion is a supersonic combustion process follows on shock wave oscillations in detonation tube. In this paper numerical studies are carried out combined effect of blockage ratio and spacing of obstacle on detonation wave propagation of hydrogen-air mixture in pulse detonation combustor. The deflagration to detonation transition of stoichiometric (ϕ=1)fuel-air mixture in channel has been analyzed for effect of blockage ratio (BR)=0.39, 0.51, 0.59, 0.71 with spacing of 2D and 3D. The reactive Navier-Stokes equation is used to solve the detonation wave propagation mechanism in Ansys Fluent platform. The result shows that fully developed detonation wave initiation regime is observed near smaller vortex generator ratio of BR=0.39 inside the combustor. The turbulent rate of reaction has also a great significance role for shock wave structure. However, vortices of rapid detonation wave are appears near thin boundary layer of each obstacle. Finally, detonation combustor demonstrates the superiority of pressure gain combustor with turbulent rate of reaction of 0.6 kg mol/m3 -s inside the detonation tube with obstacle spacing of 12 cm, this blockage enhanced the turbulence intensity and propulsive thrust. The successful detonation wave propagation speed is achieved in shortest possible time of 0.031s with a significance magnitude of 2349 m/s, which is higher than Chapman-Jouguet (C-J) velocity of 1848 m/s. Furthermore, stronger propulsive thrust force of 36.82 N is generated in pulse time of 0.031s.

A Study on the Spacing between the Sand Drain Wells (모래기둥의 설치 간격에 관한 연구)

  • 김홍택
    • Geotechnical Engineering
    • /
    • v.8 no.1
    • /
    • pp.67-80
    • /
    • 1992
  • An analytical solution method is presented to determine the radius of influence circle of a sand 4rain well(i.e., spacing between the sand drain wells) required in the design under various types of construction loading. The proposed method deals with a sand drain well having a smeared zone at the periphery of the drain well as well as flow resistance in the drain well. The method proposed in the present study is made based on the modification of 01son's solution which deals with a single ramp loading without considering smeard zone effect as well as flow resistance in the drain well. Further, the effects of various design paramenters on the drain spacing are analyzed using the proposed method.

  • PDF

Installed Spacing and Reponse Time Index of Heat Detection Devices (열감지장치의 응답시간지수와 경계구역)

  • 권오승;이복영;김동석
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.72-75
    • /
    • 1996
  • The objectives of this paper investigate the effect of installed spacing on the activation of spot type heat detection devices. The flow of hot gases under a ceiling resulting from the impingement of a fire plume activates heat detectors and sprinklers. Local temperature and velocity in this ceiling jet are usually expressed with the function of a ceiling height, the distance from a fire location and the heat release rate of fire. And detectors having different. RTI respond in different ways to the same temperature and velocity of ceiling jet. Thus great care should be taken to decide installed spacing of heat detection devices by considering above effects.

  • PDF

Effect of the spanwise grid spacing and treatment of convection term in DES

  • Song, Chi-Su;Park, Seung-O
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.8 no.2
    • /
    • pp.1-10
    • /
    • 2007
  • A two-dimensional backward facing step flow was comptuted using a Detached Eddy simulation(DES) based on the SST turbulence model. The expansion ratio(ER) was 1.125 and the Reynolds number based on the step height and the mean velocity in the upstream channel was 37,500. The flow condition was the same as with the experimental research[1]. The reattachment length, oscillatory characteristics of the flow and the coherent structures of the present simulation were compared to demonstrate the improtance of spanwise grid spacing.

Effects of Alloying Elements and Pro-eutectoid Ferrite on Mechanicl Properties in Medium Carbon Steels (중탄소강에서 합금원소 및 초석 페라이트가 기계적성질에 미치는 영향)

  • 심혜정;송형락;남원종
    • Transactions of Materials Processing
    • /
    • v.13 no.4
    • /
    • pp.350-358
    • /
    • 2004
  • The effects of alloying elements on microstructural features and mechanical properties in 0.55%C medium carbon steels were investigated. The samples were austenitized at 105$0^{\circ}C$ for 30min. followed by quenching in a salt bath in the temperature range of 500 ~ $620^{\circ}C$. The addition of Cr resulted in the decrease of the volume fraction of pro-eutectoid ferrite and interlamellar spacing in pearlite and the increase of strength. However, the addition of B caused the increase of the volume fraction of pro-eutectoid ferrite. Reduction of area and Charpy impact values were influenced by the combined effect of microstructural features, such as the volume fraction of pro-eutectoid ferrite, interlamellar spacing and the thickness of lamellar cementite in pearlite.

Dendritic Growth in $14.6K_2O-85.4SiO_2$ Glass ($14.6K_2O-85.4SiO_2$ 유리에서 Dendrite의 성장)

  • 김성식;박현수;김종희
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.3
    • /
    • pp.41-45
    • /
    • 1985
  • An experimental study has been carried out to investigate the effect of growth rate V and time on secondary dendrite arm spacing of cristobalite dendrites in $14.6K_2O-85.4SiO_2$ glass by means of x-ray diffractormetry optical microscopy and scanning electron microscopy The scanning lectron microscopy reveals a two-phase layer of dendritic crystals and interstitial melt which grow from the surface at a constant rate. Based on this experiment secondary arm spacing is proportional to V-0.24 and dendrite coarsening during isothermal holding shows that the secondary arm spacing increases with increasing heat-treatment time.

  • PDF

Laminar Flow over Two Spheres in a Tandem Arrangement (직렬로 배열된 두 개의 구를 지나는 층류 유동)

  • Kim Dong-Joo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.480-488
    • /
    • 2006
  • Numerical simulations of flow over two spheres placed in a tandem arrangement are conducted to investigate the effect of the inter-sphere spacing on the flow characteristics. The Reynolds numbers considered are 100, 250, 300 and 425, corresponding to steady axisymmetric, steady planar-symmetric, unsteady planar-symmetric, and unsteady asymmetric flows, respectively, in the case of a single sphere. For small inter-sphere spacings, the flow past two spheres is more stable than that past a single sphere. For example, with the spacing of the sphere radius, the flow is steady axisymmetric up to Re=300. However, for relatively large spacings, the flow past two spheres becomes unstable and vortex shedding takes place even at Re=250. The drag coefficient of the rear sphere decreases significantly with decreasing inter-sphere spacing due to reduction of the stagnation pressure, thus being smaller than that of the front sphere. Also, the rear sphere shows large fluctuations of the lift force as compared to the front one in the case of unsteady flow.

Performance Analysis with Change in Design Parameters of $CO_2$ Heat Pump Gas Cooler ($CO_2$ 히트펌프 가스쿨러의 설계변수 변화에 따른 성능해석)

  • Chang, Young-Soo;Kim, Min-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.639-644
    • /
    • 2006
  • The outlet temperature of gas cooler has a great effect on the efficiency of carbon dioxide heat pump system. In order to obtain a small approach temperature difference at gas cooler, near-counter flow type heat exchanger has been proposed, and larger heat transfer area is demanded. The optimum design of gas cooler involving the analysis of trade-offs between heat transfer performance and cost is desirable. In this study, the effects of geometric parameters, such as the circuit arrangement, tube diameter, transverse tube spacing, longitudinal tube spacing and the number of tube rows and fin spacing on the performance of heat transfer were investigated using the developed model. This study suggested various simulation results for optimum designs of gas cooler.

  • PDF

Heat Transfer Characteristics of Radiation-Mixed Convection in a Three-Dimensional PCB Channel (3차원 PCB 채널내에서의 복사-혼합대류 열전달 특성)

  • Lee, J.H.;Park, K.W.;Pak, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.561-575
    • /
    • 1996
  • The interaction of turbulent mixed convection and surface radiation in a three-dimensional channel with the heated blocks is analyzed numerically. Two blocks are maintained at high temperature and the other bottom and horizontal walls are insulated. S-4 method is employed to calculate the effect of the radiative heat transfer. The low Reynolds number k-$\varepsilon$ model proposed by Launder and Sharma is used to estimate the turbulent influence on the heat transfer enhancement. From above modeling, the effects of various channel specifications on the flow and heat transfer characteristics are investigated. The variables used for the present study are Reynolds number, block spacing, the channel height spacing for block and the emissivity. Average Nusselt numbers along the block surfaces are correlated and presented in terms of Reynolds number, emissivity and dimensionless geometric parameters. For the range of conditions in this study, average Nusselt numbers along the block surfaces are strongly influenced by the Reynolds numbers and channel height spacing for block but weakly influenced by the block spacing and the emissivity of the adiabatic walls.

  • PDF

Analysis of the Ultrasonic Beam Profile Due to Variation of the Inter-Element Spacing for the Phased Array Transducer (페이즈드 어레이 트랜스듀서에 있어서 구성 압전소자의 간격 변화에 따른 초음파 빔 전파 특성 해석)

  • Choe, Sang-U;Lee, Jun-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.972-981
    • /
    • 2000
  • The phased array transducer has two distinct advantages. One is rapid scanning comparing with the conventional mechanical or manual scanning system. Therefore, output image is represented in real-time. The other is the dynamic focusing and the dynamic steering of ultrasonic beam. Only the delay times that are controlled electrically are used to focus and to steer beam without any lenses or wedges. In this study, the profile of the ultrasonic beam for the phased array transducer has been simulated in the Huygens principle with varying the inter-element spacing of the linear phased array transducer. From the result of this study, it was found that the ultrasonic beam spread wider as the inter-element spacing was decreased. However, the focusing effect was improved, even when the number of the element was not big. In addition, there was grating lobes that are constructed when the inter-element spacing is more than half wavelength. However, this grating lobe has lower amplitude than the main lobe.