• Title/Summary/Keyword: space technology

Search Result 9,539, Processing Time 0.037 seconds

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul - (대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Lee, Myung-Hun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.491-499
    • /
    • 2020
  • Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

The Influence of the Landscaping Shade Membrane's Brightness on the Mean Radiant Temperature(MRT) of Summer Outdoor (조경용 차양막 재료의 명도가 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.65-73
    • /
    • 2015
  • The purpose of this study was to compare the Mean Radiant Temperature(MRT) under two landscaping shade membranes, white and black, with those of natural outdoor spaces at summer midday. An additional perforated black shading net was applied and compared for the consideration of the practical application. The average MRT at the height of 2.4m, 10cm below the membranes of black, white, and perforated black were $49.1^{\circ}C$, $41.6^{\circ}C$ and $36.8^{\circ}C$ respectively, while that of open sky was $41.8^{\circ}C$. This indicates that a closer position to the darker membrane caused a higher MRT. At the height of 1.1m and 1.7m, the difference of MRT between the black and the white membranes was slight, while the value of white was unexpectedly higher than the black. The MRT of black perforated net showed the lowest value at every height. The black membrane absorbed more solar radiation than the white, which caused the greater release of long wave radiation and higher temperature near the membrane itself. In spite of the higher albedo of the white membrane, the higher solar radiation transmittance rate of which seemed to cause the slightly higher MRT than the black at the hight of 1.1m and 1.7m. In summary, the performance of the black membrane was slightly better than the white in terms of the air conditioning of the human related space around the height of 1.1m and 1.7m, when the shading membranes were at 2.5m height.

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Characteristics of Low Density Fiberboards Bonded with Different Adhesives for Thermal Insulation (II) - Formaldehyde·Total Volatile Organic Compounds Emission Properties and Combustion Shapes - (다양한 접착제로 제조한 단열재용 저밀도섬유판의 특성(II) - 폼알데하이드·총휘발성유기화합물 방출 특성 및 연소 형상 -)

  • Jang, Jae-Hyuk;Lee, Min;Kang, Eun-Chang;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.580-587
    • /
    • 2017
  • Woodfiber insulation board can be considered as a one of the key material for low energy consumption, comfortable and safety construction of residential space because of its eco-friendly and high thermal insulation performance. This study was carried out to investigate the formaldehyde (HCHO) total volatile organic compounds (TVOC) emission properties and combustion shapes by flame test of low density fiberboards (LDFs) prepared with different adhesives. HCHO TVOC emission and combustion properties of LDFs prepared by melamine urea formaldehyde (MUF), phenol formaldehyde (PF), emulsified methylene diphenyl diisocyanate (eMDI) and latex resin adhesives were measured by desiccator method, 20 L chamber method, and flame test, respectively. As results, LDFs manufactured by MUF, eMDI and latex resin adhesives satisfied the Super $E_0$ grade of HCHO emission performance except PF resin. Furthermore, TVOC emission of all LDFs were satisfied the Korean indoor air quality standard (below $400{\mu}g/m^2{\cdot}h$). Especially, LDF with eMDI resin adhesive showed the lowest HCHO and TVOC emissivity, that $0.14mg/{\ell}$, $12{\mu}g/m^2{\cdot}h$, respectively. However, eMDI emitted the small amount ($3{\mu}g/m^2{\cdot}h$) of toluene in VOC components. In the flame test, LDF with MUF resin adhesives showed the most favorable shape after flame test compare to LDFs prepared other adhesives. Based on HCHO and TVOC emission, and combustion shapes, MUF resin adhesive may be recommended to prepare LDF for insulation purpose.

Analysis of Nutritional Components and Physicochemical Properties of Hot-air Dried Jerusalem Artichoke (Helianthus tuberosus L.) Powder (열풍 건조한 돼지감자 분말의 영양성분 및 이화학적 특성 분석)

  • Kim, Ha-Neul;Yu, Seok-Yeong;Yoon, Won-Byong;Jang, Sun-Min;Jang, Yong-Jin;Lee, Ok-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.73-78
    • /
    • 2014
  • This study investigated the nutritional components and physicochemical characteristics of Jerusalem artichoke. The moisture, crude protein, crude fat, crude ash and carbohydrate content of the Jerusalem artichoke were $5.06{\pm}0.08$, $8.30{\pm}0.26$, $0.70{\pm}0.16$, $5.04{\pm}0.03$, and 80.90%, respectively. The total sugar content of Jerusalem artichoke was $50.48{\pm}1.11$ mg/g, and the Hunter color space coordinates were $L=94.16{\pm}0.03$, $a=0.32{\pm}0.01$ and $b=0.30{\pm}0.01$. The water binding capacity and water activity of the Jerusalem artichoke were $4.06{\pm}0.16$ g/g and $0.245{\pm}0.005$, respectively. The total amino-acid content of the Jerusalem artichoke was $1.337{\times}10^4$ mg/kg, and essential amino acid was 2,737 mg/kg. The total free sugar of the Jerusalem artichoke was 4.12%. Linoleic acid (0.21%) was found to be a common fatty acid in the Jerusalem artichoke. Among the minerals, potassium (2,489 mg%) was found to be the most abundant in the Jerusalem artichoke. The total phenol and flavonoid contents were $3.06{\pm}0.07$ mg GAE/g and $1.89{\pm}0.03$ mg QE/g, respectively. The vitamin C content of the Jerusalem artichoke was $3.43{\pm}0.07$ mg%.

Effect of Crop Rotation on the Growth of Sesame(Sesamum indicum L.) and Soil Properties (윤작이 참깨의 생육과 토양의 이화학성에 미치는 영향)

  • Kim, Dong-Hwi;Seo, Jong-Ho;Kim, Chung-Guk;Choi, Seong-Ho;Ko, Mun-Hwan;Heo, Il-Bong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.3
    • /
    • pp.216-224
    • /
    • 1998
  • The objective of this study was to investigate the effect of sesame monoculture and sesame in rotation (SR) with maize. soybean. barley or rye on reduction of injury by continous cropping in sesame. Field studies were conducted for 3-years (1995~1997) at the experimental field of the Crop Experiment Station. Compared to CS (continuous sesame). SR treatments turned out to keep more organic matter and higher exchangeable cation concentrations in soils. BS (barley and sesame in a 1-year rotation) and RS (rye and sesame in a 1-yea r rotation) treatments had significantly greater available $P_2O_5$ contents in soils than CS, MS (maize and sesame in a 3-year rotation) and SbS (soybean a nd sesame in a 3-year rotation). The pH of the soils under different treatments were not significantly different. SR treatments exhibited significantly lower bulk density and higher pore space than CS. Soil microbial biomass C (SMBC) and N (SMBN) were determined by the chloroform fumigation-extraction method. SMBC and SMBN were significantly higher in soils under BS and RS than those under CS, but only during the 1 year of monitoring. MS and SbS treatments resulted in higher SMBC and SMBN than CS. The occurrence of injury by disease of sesame is the important primary factor of injury by continous cropping, but the disease occurrence with rotation did not decrease in th is experiment. Under CS treatment, the growth and grain of sesame was significantly lower than those under other treatments. Compared to CS, the increments of grain yield of sesame were 68, 63, 57 and 51% for MS, RS, SbS and BS, respectively in the first harvest. In the second harvest, they were 24% for MS, 28% for RS, 20% for SbS and 19% for BS. The average increase ratios during the two years were 41, 41, 34, and 33% for MS, RS, SbS and BS, respectively.

  • PDF

Analyzing the Improvement and Using Realities for the Songrim Woodlands Management in Hadong, Gyeongsangnamdo (하동 송림 관리 및 이용실태와 개선방안 분석)

  • Hwa, Sam Young;Park, Jae-Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.3
    • /
    • pp.315-322
    • /
    • 2013
  • This study was carried out to establish a management program and soil restoration plan through analysis of soil properties and visitor questionnaires in Songrim in Hadong, Korea. Soil bulk density in Songrim was slightly higher in the closed-woodlands ($1.31g/cm^3$) than in the open-woodlands ($1.39g/cm^3$). Soil bulk density in the closed-woodlands was higher in walking trails ($1.74g/cm^3$) than in forest areas ($1.39g/cm^3$), while the rates of pore space were lower in walking trails (42.6%) than in forest areas (50.5%). The soil porosity were lower in the closed-woodlands (34.6%) than in the open-woodlands (42.6%). Soil strength in surface soil was slightly lower in the open-woodlands ($8.5kgf/cm^2$) than in the closed-woodlands ($10.5kgf/cm^2$). The content of organic matter, total nitrogen and exchangeable cations of the woodlands was low compared with the optimum nutrient content for tree growth in Korea forest soil. According to the survey, the objective of visiting in Songrim was to enjoy recreation and landscape views. To conserve pine forest ecosystems in Songrim, the respondents said that it needs to the implement of closed-woodland periods, the establishment of smoking free zone, and the prohibition of garbage throwing and alcohol including disciplinary rules and education. Also the respondents said that pine forest ecosystem in Songrim is relatively sound, but the woodlands require the intensive management to the ecosystem and the introduction of native understory vegetation, such as grasses under pine forest ecosystem. It is recommended to designate the rest-year forest for a proper period in all woodlands to restore the Songrim soil rather than the alternation application between the rest-year for three years or non-rest-year trails, and to open partially the walking trails across the woodlands after the period. In addition, the forest within the woodland is need to designate a long-term rest-year.

Removal of Mixed Gases of H2S and NH3 by the Biofilter Packed with Biomedia (Biomedia를 충전한 Biofilter에서 H2S와 NH3 혼합악취의 제거)

  • Lim, Joung Soo;Cho, Wook Sang;Lee, Eun Young
    • Clean Technology
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2006
  • When ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) in binary mixture gases were supplied to a biofilter packed with biomedia made of polyurethane, PVA, and worm cast. No odor gases were detected on the outlet of the biofilter when $NH_3$ and $H_2S$ were separately supplied to the biofilter at space velocity(SV) of $50h^{-1}$ until inlet $NH_3$ concentration was increased up to 300 ppmv and inlet $H_2S$ to 428 ppmv. While, inlet $NH_3$ concentration maintained at 50 ppmv, inlet $H_2S$ concentration increased from 1 to 489 ppmv, and the removal efficiency of each gas was investigated. After that, $NH_3$ concentration increased step by step such as 80, 100, 200, 300, 400 and 500 ppmv. $H_2S$ concentration increased gradually when $NH_3$ concentration was set up at each condition. Under each condition, removal efficiency of $NH_3$ and $H_2S$ gas was investigated by analysing the gases sampled from the inlet and outlet of the biofilter. When binary gases were supplied to the biofilter and inlet $NH_3$ concentration was increased from 50 to 300 ppmv, elimination capacity of $NH_3$ increase linearly as inlet loading increased to $11.14g\;N{\cdot}m^{-3}{\cdot}h^{-1}$. However, as inlet $NH_3$ concentration increased over 300 ppmv, both removal efficiency and elimination capacity decreased while inlet loading increased. $H_2S$ removal efficiency was not affected seriously by the simultaneous supply of $NH_3$ when maximum inlet loading of $H_2S$ was under $40.27S{\cdot}m^{-3}{\cdot}h^{-1}$ and maximum inlet loading of $NH_3$ was under $15.25N{\cdot}m^{-3}{\cdot}h^{-1}$.

  • PDF

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.

Research about a structure system of the bus information system which is applied to the bus stop - Around a problem and preference of Pusan bus information system investigation - (버스정류장에 적용된 버스정보시스템의 구성 체계에 관한 연구 - 부산시 버스정보시스템의 문제점 및 선호도 조사를 중심으로 -)

  • Cha Min-Jun;Hong Kwan-Seon
    • Archives of design research
    • /
    • v.19 no.4 s.66
    • /
    • pp.61-70
    • /
    • 2006
  • The functions and roles in the various fields of modern society are changing into the unified and multiplex structure, which is simultaneous and virtual communication environments beyond physical space and time, by the digital IT technology. The urban traffic system is also being intellectualized in order to solve urban traffic problems and convenient services by using digital IT technology. The bus, which is the one of the most common public transportation, are suffering in the decrease of bus service quality and the bus passengers rate because of the development of other public transportation systems such as the subway and electric railway and by rapidly increasing private cars. By recognizing these problems, many domestic and overseas cities are promoting to introduce the Bus Information System (BIS) to improve service quality of buses through the intelligent traffic system. According to the construction of this new information system called the Bus Information System (BIS), the new bus stop configuration system and design plans are being required to solve the existing bus stop information system. Therefore, this research was conducted to suggest an effective BIS configuration system plan and synthetic design goals based on the investigation the problems of the information system and the BIS configuration system for Busan city. Also, this research are conducted the below actions as follows: First, the literature survey was conducted, such as theoretical documents on the bus stop and the Bus Information System(BIS), Also, the design trend of the BIS was examined through domestic and overseas BIS cases studies. Scondly, the problems related to the information system in Busan city bus stops were investigated to investigate the present state and problems of the Bus Information System (BIS). Finally, as a result of this research, the effective BIS configuration system plan and design approach methods of bus stops were proposed for by Busan city based on the above investigation results.

  • PDF