• Title/Summary/Keyword: space radiation measurement

Search Result 109, Processing Time 0.048 seconds

Space Radiation Measurement on the Polar Route onboard the Korean Commercial Flights

  • Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Choi, Ho-Sung;Rho, Su-Ryun;Cho, Il-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.1
    • /
    • pp.43-54
    • /
    • 2010
  • This study was performed by the policy research project of Ministry of Land, Transport and Maritime Affairs, which title is "Developing safety standards and management of space radiation on the polar route". In this research, total six experiments were performed using Korean commercial flights (B747). Three of those are on the polar route and the other three are on the north pacific route. Space radiation exposure measured on the polar route is the average 84.7 uSv. The simulation result using CARI-6M program gives 84.9 uSv, which is very similar to measured value. For the departure flight using the north pacific route, the measured space radiation is the average 74.4 uSv. It seems that is not so different to use the polar route or not for the return flight because the higher latitude effect causing the increase of space radiation is compensated by the shortened flight time effect causing decreasing space radiation exposure.

Radiological Safety Perception Change after Spatial Dose Measurement of Radiology Department Students (방사선학과 학생들의 공간선량 측정 경험이 방사선 안전 인식에 미치는 영향)

  • Moon, Jae Mi;Park, Sang Tae;Yu, Ji Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.174-180
    • /
    • 2015
  • There are currently many research papers on the knowledge, perceptions and actions of radiation-related staff, but hardly any papers on radiation major students in college who are to be staff members of radiation related jobs in the future. It is of course important to understand the perceptions of staff working on the lines and change their knowledge and perceptions, but in the long term it seems more efficient to understand those who are in the stage of being educated to be staff members-their knowledge and perception of radiation so that ultimately they can attain the right kind of understanding. Therefore the aim of this study is to grasp the pre-radiation staff's basic concept of radiation and space dose, their understanding of radiation safety based on this, and whether there is a change in their perception before and after the space dose measurement experiment; in the end this is to see if the space dose measurement experiment is effective in changing perception on radiation safety. This study took as its subject 64 students majoring radiation in college, I.e. pre-radiation staff members, and gauged their basic conceptualization of radiation, understanding of space dose, and understanding of radiation safety; in the X-ray room within the department the students were asked to measure space dose for themselves, so as to see whether there was a change in their understanding of radiation safety before and after the experiment, according to their understanding of the basic concept of radiation and of space dose. As a result of the space dose measurement experiment, students' increased basic knowledge of concept of radiation and understanding of the dangers of space dose were noteworthy, and accordingly their understanding of radiation safety became stricter and more conservative. In spite of this, their work ethic stayed in the lead of their understanding of radiation safety; this implies the need of a more departmentalized safety education program. Therefore instead of safety education that simply uses visual-audial material in a kind of lecture, I suggest here that there be a more experiential safety education program that enables learners to try out space dose measurement experiments for themselves, a work ethic education that aims for a conventional point of view towards radiation safety as well as a stern attitude.

The Wireless Radiation Measurement Using Embedded System (임베디드 시스템에 의한 방사선의 무선계측)

  • Kim, Hyong-Jong;Park, Dae-Sung;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Radiation is used in various field, including medical science, engineering science, agricultural science and other industrial fields and the use frequency of radiation is increasing thanks to the development of radiation technology. Although radiation contributes to the mankind so much, we must pay attention to radiation damage by its influence on human body. To use radiation properly and prevent the radiation damage, it is necessary to measure radiation exactly and to practice thorough research and education on the basis of this measurement. In this study, I suggest the method to measure radiation wirelessly without the limit of time and space, not approaching radiation having a harmful effect on human body by using ubiquitous computing technology. For the realization of suggested method, the wireless transmission technology of CDMA network is used and after installing embedded system in PDA, the measurement value is displayed through accessing CDMA network with PDA in radiation measurement system of having fixed IP. If we use the proposed method of this study, we don't have to approach radiation that is harmful to the human and can read the measurement value that is marked in PDA through CDMA network by radiation measurement system of having fixed IP.

  • PDF

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Radiation Dose Measurement and Model Comparison at the Flight Level (비행고도 상에서의 우주방사선 관측 및 모델 비교)

  • Yi, Wonhyeong;Kim, Jiyoung;Jang, Kun-Il
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.2
    • /
    • pp.91-97
    • /
    • 2018
  • High-energy charged particles are comprised of galactic cosmic rays and solar energetic particles which are mainly originated from the supernova explosion, active galactic nuclei, and the Sun. These primary charged particles which have sufficient energy to penetrate the Earth's magnetic field collide with the Earth's upper atmosphere, that is $N_2$ and $O_2$, and create secondary particles and ionizing radiation. The ionizing radiation can be measured at commercial flight altitude. So it is recommended to manage radiation dose of aircrew as workers under radiation environment to protect their health and safety. However, it is hard to deploy radiation measurement instrument to commercial aircrafts and monitor radiation dose continuously. So the numerical model calculation is performed to assess radiation exposure at flight altitude. In this paper, we present comparison result between measurement data recorded on several flights and estimation data calculated using model and examine the characteristics of the radiation environment in the atmosphere.

Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen (이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

CURRENT TRENDS IN IONIZING RADIATION DETECTION

  • Wehe David K.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.311-318
    • /
    • 2006
  • Ionizing radiation is a both a natural and man-made phenomena that plays a major role in contemporary applications. The detection of this radiation has evolved over the past several decades from simple observations to precise measurements in space, time, and energy, even in harsh environmental conditions. Tn this paper, we present a snapshot of the current state-of-the-art in radiation measurement technology, highlighting the major applications and detector developments.

A Study on Monopole Antenna Radiation Pattern inside Vehicle (차량 내부에서의 모노폴 안테나 방사패턴 연구)

  • Lee, Tae-Hak;Pyo, Seong-Min;Park, Sang-Myeong;Kim, Young-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4537-4542
    • /
    • 2010
  • In this paper, the antenna radiation pattern inside the vehicle is presented for observing the change occurring in non-anechoic environment using monopole antenna. The environment for radio communication can be affected by antenna characteristic variation inside the small space existing multi reflection waves. To perform simulation and measurement about antenna radiation pattern, the radio frequency bands for GPS and Wibro services expected to use inside the vehicle is selected. The simulation is based on the ray-tracing method and the radiation pattern is measured inside the vehicle and in free space using monopole antenna having those frequency bands. In accordance with the measurement and simulation results, when two antennas are put inside the vehicle, the omni-directional characteristic of the antenna is maintained but the received power is increased than free space case and the difference between the each case of measurements is increased as the operating frequency is increased.

Measurement of Environmental Radiation according to Altitude above Sea Level in National Park (국립공원의 해발고도에 따른 환경방사선 측정)

  • Ji, Tae-Jeong;Lee, In-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.694-701
    • /
    • 2012
  • This study set put to measure the environmental radiation for mountainous regions of National Parks where Integrated Environmental Radiation Monitoring Network is not installed. For the measurement method, the space dose was classified at 1 meter high from the surface and the index dose at the surface. The measured radiation energy measured gamma, alpha and beta rays. For selection of national parks, we selected 10 national parks which are within the same distribution in the southern part and central part of the nation. For measurement equipment, INTERCEPTOR$^{TM}$(Thermo, USA, 2006) was used for gamma rays. As for the results of the measurements, for the space gamma dose, a high level was measured at a sea level of 500 meter in national parks with an altitude of less than 1,000 meter. It was found that the value was more than $0.23{\mu}Svh^{-1}$ especially in Bukhan Mountain, Gyeryong Mountain and Wolchul Mountain. In national parks with an altitude of more than 1,000 meter, $1.77{\mu}Svh^{-1}$ was measured at 1,500 meter at Seorak Mountain. Therefore, this is 10 times greater than the background standard dose. The national parks were there were no significant changes in dose were Naejang Mountain, Sobaek and Jiri Mountains. For the measurement of the index dose, a high dose level was measured at middle altitudes of 500 meter and 1,000 meter. For measurement according to the composition types of crust, high doses were recorded at national parks composed of rocks and a lower environmental radiation level was measured at Hanra Mountain where volcanic activities have occurred.