• Title/Summary/Keyword: source zone

Search Result 547, Processing Time 0.028 seconds

Seismic Amplitude and Frequency Characteristics of Gas hydrate Bearing Geologic Model (가스 하이드레이트 지층 모델의 탄성파 진폭 및 주파수 특성)

  • Shin, Sung-Ryul;Lee, Sang-Cheol;Park, Keun-Pil;Lee, Ho-Young;Yoo, Dong-Geun;Kim, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.116-126
    • /
    • 2008
  • In gas hydrate survey, seismic amplitude and frequency characteristics play a very important role in determining whether gas hydrate exists. According to the variation of source frequency and scatterer size, we study seismic amplitude characteristics using elastic modeling applied at staggered grids. Generally speaking, scattering occurs in proportion to the square of source frequency and the scatterer volume, which has an effect on seismic amplitude. The higher source frequency is, the more scattering occurs in gas hydrate bearing zone. Therefore, BSR is hardly observed in high frequencies. On the other side, amplitude blanking zone and BSR is clearly observed in lower frequencies although the resolution is poor as a whole. Seismic reflections traveling through free-gas layer below gas hydrate bearing zone decay so severely a high frequency component that a low frequency term is dominant. Amplitude anomaly of BSR result from high acoustic impedance contrast due to free-gas, which is a very crucial factor to estimate gas hydrate bearing zone. Seismic frequency analysis is carried out using wavelet transform method that frequency component could be decomposed with time variation. In application of wavelet transform to the seismic physical experiments data, we can observe that reflections traveling through air layer, which corresponds to the free-gas layer, decay a high frequency component.

Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition (유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성)

  • Park, Chan-Su;Cho, Dae-Hwan;Jeon, Cheol-Kyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

Prediction of Worker's Exposure in a Uniform Freestream (균일류 하에서 작업하는 근로자의 노출농도 예측)

  • Jung, Yu-Jin;Kim, Hwan-Tae;Ha, Hyun-Chul;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.2
    • /
    • pp.140-149
    • /
    • 2000
  • In industrial field, there are several operations where a horizontal unidirectional airflow is used to control airborne contaminants. When a worker is immersed in a uniform freestream, a recirculating airflow can be created downstream of the worker by the phenomenon of boundary layer seperation. If the contaminant source and the breathing zone are within this near-wake region, high exposure may occur. The investigation for the effect of contaminant source location on worker exposure was performed by using CFD(Computational Fluid Dynamics). The airflow field was numerically calculated by assuming a steady flow and using the standard $k-{\varepsilon}$ turbulence model. As the results were compared with experimental data, the applicability of CFD was successfully verified. Subsequently, the breathing zone concentrations of the worker were predicted and compared with experimental data. The effects of contaminant density and turbulence intensity of freestream on worker exposure were evaluated.

  • PDF

Background impurity incorporation in the growth of InP by hydride vapor phase epitaxy technique (Hydride 기상증착법을 이용한 InP 성장에서의 배경 불순물 도입에 관한 연구)

  • Chinho Park
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.2
    • /
    • pp.141-154
    • /
    • 1996
  • Intrinsic layers of homoepitaxial InP grown by the hydride vapor phase epitaxy (VPE) technique were investigated by Fourier-transform photoluminescence(FTPL) and variable temperature Hall measurements. The effect of process variables (i.e., source zone temperature and inlet mole fractions of HCl and $PH_{3}$) on the backgroudn impurity levels was investigated. The background carrier concentration was found to decrease with decreasing source zone temperature and increasing HCl, but was relatively independent of $PH_{3}$ for the range of mole fraction studied. The presence of background donors and acceptors was clearly verified in the FTPL spectra, and the major impurities were tentatively identified as Si donors and Zn acceptors as well as some unidentified acceptors.

  • PDF

Estimation of seismicity parameters of the seismic zones of the Korean Peninsula using incomplete and complete data files (불완전한 자료 및 완전한 자료 목록을 이용한 한반도 지진구들의 지진활동 매개변수 평가)

  • 이기화
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.23-30
    • /
    • 1998
  • An estimation of seismic risk parameters by seismic zones of the Korea Peninsula in order to calculate the seismic hazard values using these was erformed. Seven seismic source zones were selected in consideration of seismicity and geology of Korean Peninsula. The seismicity parameters that should be estimated are maximum intensity, activity rate and b value in the Gutenberg - Richter relation. For computation of these parameters, least square method or maximum likelihood method is applied to the earthquake data in two ways; the one for the data without maximum intensity and the other with maximum intensity. Earthquake data since Choseon Dynasty is regarded as complete and estimation of parameters was made for these data using above two ways. And recently, a new method is published that estimate the seismicity parameters using mixed data containing large historical events and recent complete observations. Therefore, this method is applied to the whole earthquake data of the Korean Peninsula. It turns out that the b value computed considering maximum intensity is slightly lower than that computed considering without maximum intensity, and it becomes still lower when the incomplete data prior to Choseon Dynasty is used. In the case of the activity rates, the values obtained without maximum intensity and that with maximum intensity are similar, though they are lower when the incomplete data is used. The values of maximum intensities are usually lower when considering incomplete data. In the seismic source zone including the Yangsan Fault zone, however, the values are higher when considering the incomplete data.

  • PDF

Best Buffer Width of Riparian Buffer Zone using a Pilot with Different Plant Species for Reduction of Non-point Pollutant Loading (비점오염저감을 위한 수변완충지대의 적정 설계)

  • Kim, Sung-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Non-point pollution is caused by many diffusive sources, unlike a point pollution derived from industrial wastewater treatment plants or sewage treatment plants. Runoff of non-point pollutants is originated from rainfall or thawing in short period of time moving over and through the a ground surface. They cause ill effect on the quality of neighboring aquatic environment. To prevent effectively the wash off from non-point pollutant, it should be immediately reduced at the source or be treated after gathering of runoff water. This study has been carried out for the best width of riparian buffer zone. So we implemented the experiment in terms of its depth, width and kind of vegetations and calculated the reduction of pollutants loading. The experimental zone encompasses the watershed of Namhan River (Kyunggido Yangpyunggun Byungsanri). The region was divided into 5 land cover sectors : grass, reed, pussy willow, mixed(grass+pussy willow) and natural zone to compare effectiveness of vegetation. Water samples from four points have been collected in different depths. And the pollutant removal efficiency by sectors with different plant species was yielded through influent with one of each sample. And we obtained the correlation between the width of riparian buffer zone and the removal efficiency of pollutants. Using correlation result, the width of riparian buffer zones which needs to improve the water quality of river could be derived.

Spinel$(MgAl_2O_4)$ single crystal growth by floating zone method (Floating zone 법에 의한 Spinel$(MgAl_2O_4)$단결정 성장)

  • Seung Min Kang;Byong Sik Jeon;Keun Ho Orr
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.3
    • /
    • pp.325-335
    • /
    • 1994
  • The spinel $MgO.Al_20_3$ single crystals were grown by FZ (floating zone) method. Its melting point is about, $2135^{\circ}C$ and is important to the process of the growth from the melt. There have been some reports of the growth by Czochralski and Verneuil method. However, this study is the first trial to the spinel crystal with the application of FZ method. In this study, $MgAl_2O_4$ spinel crystals were grown by using FZ method which uses the ellipsoidal mirror furnace having infrared halogen lamps as a heat source. With dopants of transition metal ions, it was possible to melt the feed rod which does not absorb the infrared rays due to the transparent properties to infrared ray of spinel itself and the red, green and blue colored spinel single crystals could be grown more easily. As a conclusion, the purpose of this study is to find the spinel single crystal growth mechanism with respect to th growth interfaces and molten zone stability and to characterize the state of growth resulting from the concavity to the melt of interfaces.

  • PDF

The Effect Factors on the Growth of Phytoplankton and the Sources of Organic Matters in Downstream of South-Han River (남한강 하류수역에서 식물플랑크톤 증식의 영향인자 및 수중유기를 기원)

  • Park, Hae-Kyung;Byeon, Myeong-Seop;Choi, Myeong-Jae;Kim, Young-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.556-562
    • /
    • 2008
  • We divided the downstream of South-Han River into three water zones, such as river zone, transition zone and lacustrine zone depending on the flow rate, and elucidated the major effect factors on the growth of phytoplankton and the sources of organic matters in each water zone. The difference of chlorophyll-a concentration which represents the standing crop of phytoplankton was statistically significant among the water zones. From the results of bivariate correlation analysis between chlorophyll-a concentration and water quality parameters in each water zone, the outflow of Chungju dam and hydraulic retention time of Lake Paldang which are directly related with the flow rate seemed to have obvious impact on phytoplankton growth in the downstream of South-Han River. The concentration of nutrients such as phosphorus and nitrogen exceeded the criterion of eutrophication and did not showed significant relationship with chlorophyll-a concentration. There were strong correlations between $BOD_5$ and chlorophyll-a concentrations in transition and lacustrine zone showing autochthonous production of phytoplankton was dominant source of organic matters in these zones especially in dry seasons. The results of this study show that the control of abundance of phytoplankton is the key target for reduction of the organic pollution in the downstream of South-Han River.

Occurrence of U-minerals and Source of U in Groundwater in Daebo Granite, Daejeon Area (대전지역 대보 화강암내 우라늄 광물의 산출상태와 지하수내 우라늄의 기원)

  • Hwang, Jeong
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.399-407
    • /
    • 2013
  • Some groundwater in Korea contains high U concentrations, especially where two-mica granite occurs in the Daejeon area. The elemental U in the two-mica granite is lower than that in normal granites elsewhere in the world, and U-minerals have yet to be reported in the two-mica granite in the Daejeon area. This study focuses on investigating the occurrence of U-minerals serving as the U source in groundwater. In situ gamma ray spectrometry and mineralogical analyses using EPMA were performed. U-count anomalies were identified in a granitic dyke and in hydrothermally altered granite. Uraniferous granitic dykes occur along the contact zone between the two-mica granite and mica-schist. The uraniferous parts within the two-mica granite are developed in the hydrothermally altered zone, which contains numerous quartz veinlets within a fracture zone. Hydrothermal alteration is dominated by potassic and prophylitic alteration. Uraninite is a common U-mineral in granitic dykes and hydrothermally altered granite. Coffinite and uranophane occur in the hydrothermally altered granite. All of these U-minerals are commonly accompanied by hydrothermal alteration minerals such as muscovite, chlorite, epidote, and calcite. It is concluded that granitic dyke and hydrothermally altered granite are the main source rocks of U in groundwater.

Hydrocarbon Source Rock Potential of Eocene Forearc and Subduction Zone Strata, Southern Oregon Coast Range, U.S.A. (미국 오레곤 남부 에오세 전호상 및 섭입대 퇴적층의 탄화수소 근원암 가능성)

  • Ryu, In-Chang
    • The Korean Journal of Petroleum Geology
    • /
    • v.11 no.1 s.12
    • /
    • pp.27-41
    • /
    • 2005
  • The hydrocarbon source rock potential of the Eocene units in the southern Oregon Coast Range was evaluated by using the Rock-Eval pyrolysis. Most Eocene units in southern Oregon Coast Range are thermally immature and contain lean, gas-prone Type III kerogen. However, some beds(coals) are sufficiently organic-rich to be sources of biogenic and thermogenic methane discovered in numerous seeps. The overall hydrocarbon source rock potential of the southern Oregon Coast Range is moderately low. Several requirements for commercial accumulations of hydrocarbon, however, probably exist locally within and adjacent areas. Three speculative petroleum systems are identified. The first includes the southern part of the Oregon Coast Range near the border with the Mesozoic Klamath Mountains and is related to a proposed subduction zone maturation mechanism along thrust faults. The second is centered in the northern part of the range and may be associated with basin-centered gas in an over-pressured zone. The third occurs near the eastern border of the range where maturation is related heating by sills and migration of hydrothermal fluids associated with mid-Tertiary volcanism in the Western cascade arc.

  • PDF