• 제목/요약/키워드: source zone

검색결과 552건 처리시간 0.031초

Numerical Modeling for GaN Deposition by MOCVD: Effects of the Gas Inlet

  • Yang, Wonkyun;Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제23권3호
    • /
    • pp.139-144
    • /
    • 2014
  • GaN deposition equipment and processes for the fabrication of white LEDs (Light Emitting Diode) using MOCVD (Metal Organic Chemical Vapor Deposition) were numerically modeled to analyze the effects of a reactive gas introduction strategy. The source gases, TMGa and $NH_3$, were injected from a shower head at the top of the chamber; the carrier gases, $H_2$ or $N_2$, were introduced using two types of injection structures: vertical and horizontal. Wafers sat on the holder at a radial distance between 100 mm and 150 mm. The non-uniformity of the deposition rates for vertical and horizontal injection were 4.3% and 3.1%, respectively. In the case of using $H_2$ as a carrier gas instead of $N_2$, the uniform deposition zone was increased by 20%.

다중 포스트의 적응형 Zoning으로 MANET을 위한 효율적 라우팅 (Adaptive Zoning with Multiple Posts for Efficient Routing in MANET)

  • 서명주;이종호;윤희용;추현승
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2002년도 춘계학술발표논문집 (하)
    • /
    • pp.1539-1542
    • /
    • 2002
  • Many routing protocols have been proposed for mobile ad-hoc networks, but most protocols do not consider the physical location of the communicating nodes. In this paper we propose adaptive zoning approach with multiple hosts for reducing the number of route request messages. The proposed approach makes the sub-request zone has shorter interval than the existing schemes between the source and destination. This results in significantly lower routing overhead than the existing schemes as verified by computer simulation.

  • PDF

적층판 이론을 이용한 용접부 각 변형량 해석에 관한 연구 (A Study on the Angular Distortion in Weldment6s using the Laminated Plate Theory)

  • 손광재;양영수;최병익
    • Journal of Welding and Joining
    • /
    • 제17권2호
    • /
    • pp.91-96
    • /
    • 1999
  • The problems of welding distortion in a welded structures are major concern in heavy industry. Weld-induced angular distortion's formula, composed weld parameter such as heat input and plate thickness, is developed analytically by the use of an elliptic cylindrical inclusion with an eigenstrain in an infinite laminated plate theory. The source of angular distortion in weldments is the plastic strains, which are caused by non-uniform temperature gradient. The distributions of the plastic strain corresponding eigenstrain are assumed by the use of Rosenthal's solution expressing thermal history. Comparison of calculated results with experimental data shows the accuracy and validity of the proposed method.

  • PDF

일본(日本)에 있어서의 사방공학연구(砂防工學硏究)의 동향(動向) (The Trend and Achievements of Erosion Control Research in Japan)

  • 우보명
    • 한국산림과학회지
    • /
    • 제20권1호
    • /
    • pp.51-60
    • /
    • 1973
  • The trend and achievments of soil erosion control research in Japan were investigated through observation tours and reference work and following facts were found to be important aspects which should be considered in the soil erosion control research program in Korea. Experiments on forest and water relations, and ground water phenomena at the water source zone in Tokyo University. Studies on land-slides and erosion control dam in Kyoto University. Studies on mud-flow and snow avalanches in Hokkaido University. Studies on sanddune fixation and disaster damage prevention forests in Kyushu University. Studies on forest denudations in Nagoya University. Studies on Greening-works and soil erosion prevention chemicals in Tokyo Agriculture University. Training on planning of erosion control works and prevention of disaster damages in Forest Research Institute. Experiments on soil erosion phenomena and infiltration in Tohoku Branch, FRI. Experiments on erosion and surface stratum failure of steep slopes and their prevention methods in Railway Technical Research Institute.

  • PDF

Assessment of riparian buffers for reducing pollution according to land-cover pattern using RS and GIS

  • Ha, Sung-Ryong;Lee, Seung-Chul;Ko, Chang-Hwan;Jo, Yun-Won
    • 대한원격탐사학회지
    • /
    • 제22권5호
    • /
    • pp.445-449
    • /
    • 2006
  • Diffuse pollution has been considering as a major source of the quality deterioration of water resources. The establishment of riparian vegetation strips or buffers along those areas of water bodies is used to reduce the threat of diffuse pollution. Remote sensing offers a means by which critical areas could be identified, so that subsequent action toward the establishment of riparian zones can be taken. On the behalf of KOMPSAT-2 satellite imagery as a high resolution spatial data, Landsat TM satellite data are used to aquire the land cover for the riparian buffers studied. This investigation aims to assess the riparian buffers established on the upper Geum river as a pollution mitigation. Through comparing the delineation of riparian buffer zones developed with the existing zones established by the government, we can find the critical distortion points of the existing riparian buffer zone.

Platycerium bifurcatum(Polypodiaceae) 잎의 발생 II. 유관속계 (Development of Mantle Leaves in Platycerium bifurcatum (Plypodiaceae) II. Vascular System)

  • 이영현
    • Journal of Plant Biology
    • /
    • 제33권1호
    • /
    • pp.31-40
    • /
    • 1990
  • Procambium developed in the histogenetical zone below the marginal meristem. The development of procambium is correlated with the developmental stage of the leaf. As long as the marginal cells are crescent-shaped, the first-order procambium develops. When the marginal cell becomes wedge-shaped, the higher order procambium appears. The reticulated venation is developed through forking and anastomosis. The meshes of the first order enlarge in the process of leaf growth and the meshes of the second and third order develop in the meshes of the first-order through the differentiation of the residual meristem. Therefore, the venation is hierachically arranged and is as recognizable from the thickening of the veins. The outermost vein is produced parallel to the leaf margin, in which the differences between the costal and intercostal parts of the marginal meristem are removed. The endodermis and pericycle differentiate from the same mother cell. The procambium and sclerenchyma originate from a common source during the first developmental stage. A small cellular cluster lies within the parenchyma at the upper and lower sides of the procambial trace and differentiates into sclerenchyma.

  • PDF

Field Studios of In-situ Aerobic Cometabolism of Chlorinated Aliphatic Hydrocarbons

  • Semprini, Lewts
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.3-4
    • /
    • 2004
  • Results will be presented from two field studies that evaluated the in-situ treatment of chlorinated aliphatic hydrocarbons (CAHs) using aerobic cometabolism. In the first study, a cometabolic air sparging (CAS) demonstration was conducted at McClellan Air Force Base (AFB), California, to treat chlorinated aliphatic hydrocarbons (CAHs) in groundwater using propane as the cometabolic substrate. A propane-biostimulated zone was sparged with a propane/air mixture and a control zone was sparged with air alone. Propane-utilizers were effectively stimulated in the saturated zone with repeated intermediate sparging of propane and air. Propane delivery, however, was not uniform, with propane mainly observed in down-gradient observation wells. Trichloroethene (TCE), cis-1, 2-dichloroethene (c-DCE), and dissolved oxygen (DO) concentration levels decreased in proportion with propane usage, with c-DCE decreasing more rapidly than TCE. The more rapid removal of c-DCE indicated biotransformation and not just physical removal by stripping. Propane utilization rates and rates of CAH removal slowed after three to four months of repeated propane additions, which coincided with tile depletion of nitrogen (as nitrate). Ammonia was then added to the propane/air mixture as a nitrogen source. After a six-month period between propane additions, rapid propane-utilization was observed. Nitrate was present due to groundwater flow into the treatment zone and/or by the oxidation of tile previously injected ammonia. In the propane-stimulated zone, c-DCE concentrations decreased below tile detection limit (1 $\mu$g/L), and TCE concentrations ranged from less than 5 $\mu$g/L to 30 $\mu$g/L, representing removals of 90 to 97%. In the air sparged control zone, TCE was removed at only two monitoring locations nearest the sparge-well, to concentrations of 15 $\mu$g/L and 60 $\mu$g/L. The responses indicate that stripping as well as biological treatment were responsible for the removal of contaminants in the biostimulated zone, with biostimulation enhancing removals to lower contaminant levels. As part of that study bacterial population shifts that occurred in the groundwater during CAS and air sparging control were evaluated by length heterogeneity polymerase chain reaction (LH-PCR) fragment analysis. The results showed that an organism(5) that had a fragment size of 385 base pairs (385 bp) was positively correlated with propane removal rates. The 385 bp fragment consisted of up to 83% of the total fragments in the analysis when propane removal rates peaked. A 16S rRNA clone library made from the bacteria sampled in propane sparged groundwater included clones of a TM7 division bacterium that had a 385bp LH-PCR fragment; no other bacterial species with this fragment size were detected. Both propane removal rates and the 385bp LH-PCR fragment decreased as nitrate levels in the groundwater decreased. In the second study the potential for bioaugmentation of a butane culture was evaluated in a series of field tests conducted at the Moffett Field Air Station in California. A butane-utilizing mixed culture that was effective in transforming 1, 1-dichloroethene (1, 1-DCE), 1, 1, 1-trichloroethane (1, 1, 1-TCA), and 1, 1-dichloroethane (1, 1-DCA) was added to the saturated zone at the test site. This mixture of contaminants was evaluated since they are often present as together as the result of 1, 1, 1-TCA contamination and the abiotic and biotic transformation of 1, 1, 1-TCA to 1, 1-DCE and 1, 1-DCA. Model simulations were performed prior to the initiation of the field study. The simulations were performed with a transport code that included processes for in-situ cometabolism, including microbial growth and decay, substrate and oxygen utilization, and the cometabolism of dual contaminants (1, 1-DCE and 1, 1, 1-TCA). Based on the results of detailed kinetic studies with the culture, cometabolic transformation kinetics were incorporated that butane mixed-inhibition on 1, 1-DCE and 1, 1, 1-TCA transformation, and competitive inhibition of 1, 1-DCE and 1, 1, 1-TCA on butane utilization. A transformation capacity term was also included in the model formation that results in cell loss due to contaminant transformation. Parameters for the model simulations were determined independently in kinetic studies with the butane-utilizing culture and through batch microcosm tests with groundwater and aquifer solids from the field test zone with the butane-utilizing culture added. In microcosm tests, the model simulated well the repetitive utilization of butane and cometabolism of 1.1, 1-TCA and 1, 1-DCE, as well as the transformation of 1, 1-DCE as it was repeatedly transformed at increased aqueous concentrations. Model simulations were then performed under the transport conditions of the field test to explore the effects of the bioaugmentation dose and the response of the system to tile biostimulation with alternating pulses of dissolved butane and oxygen in the presence of 1, 1-DCE (50 $\mu$g/L) and 1, 1, 1-TCA (250 $\mu$g/L). A uniform aquifer bioaugmentation dose of 0.5 mg/L of cells resulted in complete utilization of the butane 2-meters downgradient of the injection well within 200-hrs of bioaugmentation and butane addition. 1, 1-DCE was much more rapidly transformed than 1, 1, 1-TCA, and efficient 1, 1, 1-TCA removal occurred only after 1, 1-DCE and butane were decreased in concentration. The simulations demonstrated the strong inhibition of both 1, 1-DCE and butane on 1, 1, 1-TCA transformation, and the more rapid 1, 1-DCE transformation kinetics. Results of tile field demonstration indicated that bioaugmentation was successfully implemented; however it was difficult to maintain effective treatment for long periods of time (50 days or more). The demonstration showed that the bioaugmented experimental leg effectively transformed 1, 1-DCE and 1, 1-DCA, and was somewhat effective in transforming 1, 1, 1-TCA. The indigenous experimental leg treated in the same way as the bioaugmented leg was much less effective in treating the contaminant mixture. The best operating performance was achieved in the bioaugmented leg with about over 90%, 80%, 60 % removal for 1, 1-DCE, 1, 1-DCA, and 1, 1, 1-TCA, respectively. Molecular methods were used to track and enumerate the bioaugmented culture in the test zone. Real Time PCR analysis was used to on enumerate the bioaugmented culture. The results show higher numbers of the bioaugmented microorganisms were present in the treatment zone groundwater when the contaminants were being effective transformed. A decrease in these numbers was associated with a reduction in treatment performance. The results of the field tests indicated that although bioaugmentation can be successfully implemented, competition for the growth substrate (butane) by the indigenous microorganisms likely lead to the decrease in long-term performance.

  • PDF

섬유/플라스틱 사출성형 복합재료의 음향방출 진폭분포에 대한 감쇠효과 (Effects of Wave Attenuation on the Acoustic Emission Amplitude Distribution of Injection-Molded Fiber/Plastic Composites)

  • 최낙삼
    • 비파괴검사학회지
    • /
    • 제18권1호
    • /
    • pp.1-9
    • /
    • 1998
  • 짧은 섬유로 강화된 열가소성수지의 복합재료를 대상 재료로 하여 AE의 발생위치(AE source location)를 구하고 AE신호의 진폭분포에 미치는 감쇠 손실(attenuation loss)의 영향을 정량적으로 검토했다. 모의 AE파를 이용하여 측정된 감쇠율은 시험편내의 섬유체적함유율의 증가에 따라 단순 선형관계식으로 예상되는 값보다 더 작았다. 시험편에서 계측된 AE진폭분포에 감쇠손실을 보정한 결과, 시험편의 게이지부에 설정된 각 구역에서 서로 유사한 수준의 진폭분포가 나타났다. 또한 보정된 AE진폭은 시험편의 변형이 진행됨에 따라 더욱 크게 되었다. 따라서, AE진폭을 이용한 고분자복합재료의 손상해석에서는 AE파의 감쇠효과를 보정해야 됨이 확인되었다.

  • PDF

An Evaluation on Citizens' Satisfaction with the Outdoor Landscape Lighting in Gyeongju Historic Areas - The Case of Wolseong District -

  • Park, So-Yeong;Heo, Sang-Hyun
    • 한국조경학회지
    • /
    • 제38권5_2호
    • /
    • pp.186-193
    • /
    • 2010
  • The purpose of this study was to survey the citizens for their satisfaction with the outdoor landscape lighting in Gyeongju Historic Areas registered as UNESCO World Cultural Heritage in November 2000 and thereupon, provide for some basic data useful to the design of the outdoor landscape lighting for the cultural properties. As a result of examining the conditions of the outdoor landscape lighting in Wolseong Zone of Anapji, Banwolseong, Dongbu Sajeokji, Cheomseongdae and Gyerim, there were found 391 lighting fixtures of 12 types in Anapji, 138 lightings of 4 types in Banwolseong, 38 lightings of 6 types in Cheomseongdae, 28 lightings of 3 types in Dongbu Sajeokji and 54 lightings of 5 types in Gyerim. As a result of analyzing citizens' satisfaction with the outdoor landscape lighting, it was found that citizens were satisfied more or less with the nightscape image changed by the outdoor landscape lighting; their satisfaction scored 3.836 on average for Anapji on a 5-point Likert type scale, 3.516 for Banwolseong, 3.446 for Dongbu Sajeokji, 3.650 for Cheomseongdae and 3.479 for Gyerim. However, citizens' satisfaction with the originality of the nightscape was generally low: 3.055 for Anapji, 2.914 for Cheomseongdae, 2.877 for Banwolseong, 2.847 for Gyerim and 2.665 for Dongbu Sajeokji. On the other hand, since most of the lighting fixtures were installed as inserted lights or floodlights, the color tones of light source were relatively highly distinctive, but the peripheral spaces around the cultural properties were rather dark, which means that citizens were feeling inconvenient more or less for using the amenities such as bench or waste box. All in all, their satisfaction with the outdoor landscape at the sample zone at night scored 2.981, lower than the normal level.

제주도의 오염 방지 시공이 부실한 지하수 관정에 대한 구간 차폐 공법의 적용과 평가 (Application and Assesment of Regrouting Method for Improperly Constructed Wells in Jeju Island)

  • 김미진;강봉래;조희남;최성욱;양원석;박원배
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권3호
    • /
    • pp.43-51
    • /
    • 2020
  • About 90% of groundwater wells in Jeju Island are reported to be under the threat of contamination by infiltration of the surface pollutants. Most of those wells have improperly grouted annulus which is an empty space between the well and the inner casing. As a remedy to this problem, some of the wells were re-grouted by filling the annulus with cement without lifting an inner casing. In order to evaluate whether this method is appropriate for the geological structure of Jeju Island, two wells (W1 and W2) were selected and this method was applied. The water holding capacity did not decrease while the nitrate levels decreased from 16.8 and 20.2 to 6.8 and 13.8 mg/L in W1 and W2, respectively. The higher nitrate level in W2 is deemed to be influenced by the livestock farms located in the upper area of the well. In addition, transmissivity of the vedose zone was higher in W2 than W1, potentially facilitating the transport of nitrate to the groundwater. The overall result of this study suggests re-grouting of wells for the purpose of protecting water quality of goundwater should take into account geological structure of vadose zone as well as appropriate source control of the contaminants.