• Title/Summary/Keyword: source separation

Search Result 454, Processing Time 0.022 seconds

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.

Numerical investigation on cavitation and non-cavitation flow noise on pumpjet propulsion (펌프젯 추진기의 공동 비공동 유동소음에 대한 수치적 연구)

  • Garam Ku;Cheolung Cheong;Hanshin Seol;Hongseok Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.250-261
    • /
    • 2023
  • In this study, the noise contributions by the duct, stator and rotor, which are the propulsor components, are evaluated to identify the flow noise source in cavitation and non-cavitation conditions on pumpjet propulsion and the noise levels in both conditions are compared. The unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equation based on the homogeneous mixture assumption is applied on the suboff submarine hull and pumpjet propeller in the cavitation tunnel, and the Volume of Fluid (VOF) method and Schnerr-Sauer cavitation model are used to describe the two-phase flow. Based on the flow simulation results, the acoustic analogy formulated by Ffowcs Williams and Hawkings (FW-H) equation is applied to predict the underwater radiated noise. The noise contributions are evaluated by using the three types of impermeable integral surface on the duct, stator and rotor, and the two types of permeable integral surface surrounding the propulsor. As a result of noise prediction, the contribution by the stator is insignificant, but it affects the generation of flow noise source due to flow separation in the duct and rotor, and the noise is predominantly radiated into the upward and right where the flow separations are. Also, the noise is radiated into the thrust direction due to pressure fluctuation between suction and pressure sides on the rotor blades, and the it can be seen that the cavitation effect into the noise can be considered through the permeable integral surface.

A Study on Real-Time Monitoring for Moisture Measurement of Organic Samples inside a Drying Oven using Arduino Based on Open-Source (오픈 소스 기반의 아두이노를 이용한 건조기 내 유기 시료의 실시간 수분측정 모니터링에 관한 연구)

  • Kim, Jeong-hun
    • Journal of Venture Innovation
    • /
    • v.5 no.2
    • /
    • pp.85-99
    • /
    • 2022
  • Dryers becoming commercially available for experimental and industrial use are classified to general drying oven, hot-air dryer, vacuum dryer, freezing dryer, etc. and kinds of them are various from the function, size and volume, etc. But the moisture measurement is not applied although it is important factor for the quality control and the performance improvement of products, and then now is very passive because the weight is weighed arbitrarily after dry-end. Generally the method for measuring moisture is divided by a direct measurement method and a indirect measurement method, and the former such as the change of weight or volume on the front and rear of separation of moisture, etc. is mainly used. Relatively a indirect measurement is very limited to apply due to utilize measurement apparatuses using temperature conductivity and micro-wave etc. In this research, we easily designed the moisture measurement system using the open-source based Arduino, and monitored moisture fluctuations and weight profiles in the real-time without the effect of external environment. Concretely the temperature-humidity and load cell sensors were packaged into a drying oven and the various change values were measured, and their sensors capable to operate 60℃ and 80℃ were selected to suitable for the moisture sensitive materials and the food dry. And also the performance safety using the organic samples of banana, pear, sawdust could be secured because the changes of evaporation rate as the dry time and temperature, and the measurement values of load cell appeared stable response characteristics through repeated experiments. Hereafter we judge that the reliability can be improved increasingly through the expansion of temperature-humidity range and the comparative analysis with CFD(Computational Fluid Dynamics) program.

Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration (성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립)

  • Jeong, Sujin;Baeck, Seungkyung;Park, Sunhye;Son, Kkonnip;Park, Yonghoon;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Liquid Chromatography-Tandem Mass Spectrometric Determination of Geniposide in Rat Plasma and its Pharmacokinetic Application

  • Jin, Ming Ji;Kim, In Sook;Kim, Dong-Hyun;Yoo, Hye Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2760-2764
    • /
    • 2013
  • Geniposide is a biologically active ingredient of gardenia fruit. A liquid chromatography-tandem mass spectrometric method was developed and validated for the determination of geniposide in rat plasma. The plasma samples were pretreated by solid-phase extraction and introduced into a BDS Hypersil $C_{18}$ column ($50{\times}2.1mm$, $5{\mu}m$) for chromatographic separation. The mobile phase consisted of 0.1% formic acid and 0.1% formic acid in acetonitrile, and gradient elution was performed at a flow rate of 0.25 mL/min. For mass spectrometric detection, multiple reaction monitoring was performed via an electrospray ionization source in positive mode. The calibration curve for geniposide was linear ($r^2=0.997$) in the concentration range of $0.005-1{\mu}g/mL$. The intra- and inter-day accuracies and precisions fulfilled the required criteria (${\pm}15%$). The developed method was subsequently used for pharmacokinetic analysis of geniposide after oral administration to rats at a dose of 50 mg/kg. The mean maximum plasma concentration of geniposide was $0.68{\pm}0.29{\mu}g/mL$ at $0.44{\pm}0.13h$, and the mean area under the plasma concentration versus time curve was $1.46{\mu}g{\cdot}h/mL$.

Phenomenal study on the dopant activation behavior in polysilicon thin films doped by non-mass separated ion mass doping technique (비질량 분리 이온 질량 주입법으로 도핑시킨 다결정 박막의 도판트 활성화 거동)

  • Yoon, Jin-Young;Choi, Duck-Kyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.1
    • /
    • pp.143-150
    • /
    • 1997
  • The electrical properties of polysilicon thin films implanted with $B_2H_6$ diluted in $H_2$ as dopant source using ion mass doping technique and the effect of radiation damage on the dopant activation behavior were investigated. Comparing the SIMS profiles of boron in polysilicon films with that obtained from computer simulation using TRIM92 the most probable ion species were $B_2H_x\;^+$(x=1, 2, 3‥‥) type molecular ions. As a result of the Implantation of energetic massive ions, a continuous amorphized layer was created in polysilicon films where the fraction of amorphized layer varied with doping time. This amorphization comes from the fact that mass separation of implanting species is not employed in this ion mass doping technique. In the dopant activation behavior, reverse annealing phenomenon appeared in the intermediate annealing temperature range for a severely damaged specimen. The experimental result showed that the off-state current of the p-channel polysilicon thin film transistor is dependent on the degree of radiation damage.

  • PDF

NEAR INFRARED REFLECTANCE SPECTROSCOPY AS A TOOL TO PREDICT QUALITATIVE AND QUANTITATIVE MEAT AND BONE MEAL PRESENCE IN COMPOUND FEEDS

  • Fernandez, Maria;Martinez, Adela;Modrono, Sagrario;De La Roza, Begona
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1269-1269
    • /
    • 2001
  • The Bovine Spongiform Encephalopathy (BSE) is one of the more important problems that have affected the economy of european cattles and the Public Safety. Their transmission is mainly through digestive system, and the compound feeds made with animal proteins are one source of infection for healthy cows. Nowadays the official method for meat and bone meal (MBM) detection in compound feeds is a microscopy technique. However, this methodology is subjective, and that alter the fact to make one exhaustive quantitative analysis and one differentiation between mammalian and poultry bones. In addition, the separation of the differents fractions in a sample by density before the analysis, requires the use of organochlorates products as $CCl_4$, which produce serious damages in the atmosphere ozone content. NIR methodology is another possible way to confirm and identifying animal ingredients in compound feeds, Its capabilities for quantitative and qualitative analysis of foods and feeds has been enought demonstrated. The objective of this work was to use NIR as a tool to make an qualitative and quantitative analysis and a prediction of the meat and bone meal presence in compound feeds from North Spain cattle farms. Using a global population of compound feeds, on make three different groups depending of MBM percentage presence (0, 0-100, 100), to build and validate one calibration equation to determine MBM content and make one discriminant analysis between these three groups. The preliminary dates obtained with another differents samples of known composition showed promising results.

  • PDF

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

Disinfection Characteristic of Sewage Wastewater Treatment Using Solar Light/TiO2 Film System (태양광/광촉매를 이용한 오폐수 살균특성)

  • Cho Il-Hyoung;Lee Nae-Hyun;An Sang-Woo;Kim Young-Kyu;Lee Seung-Mok
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.677-688
    • /
    • 2006
  • Currently, the application of $TiO_2$ photocatalyst has been focused on purification and treatment of wastewater. However, the use of conventional $TiO_2$ slurry photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we studied that solar light/$TiO_2$ film system was designed and developed in order to examine disinfection characteristics of sewage wastewater treatment. The optimum conditions for disinfection such as solar light intensity, characteristic of sewage wastewater, amounts of $TiO_2$ and comparison of solar ligth/$TiO_2$ systems with UV light/$TiO_2$ system was examined. The results are as follows: (1) photocatalytic disinfection process with solar light in the presence of $TiO_2$ film more effectively killed total coliform (TC) than solar light or $TiO_2$ film absorption only. (2) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with remain resistant material. (3) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with the increase of amounts of $TiO_2$. (4) TC survival ratio decreased linearly with increasing UV light intensity. (5) The disinfection effect of solar light/$TiO_2$ slurry system decreased more than UV light/$TiO_2$ film systems. (6) The disinfection reaction followed first-order kinetics. We suggest that solar light instead of using artificial UV light was conducted to investigate the applicability of alternative energy source in the disinfection of TC and the degradation of organic material.

Shallow gas origin in the sediment near coastal area of Busan (부산 주변 해역 해저 퇴적물 내 공기층 가스 기원)

  • Kim, Ji-Hoon;Han, Hyun-Chul;Cheong, Tae-Jin;Lee, Young-Joo
    • The Korean Journal of Petroleum Geology
    • /
    • v.13 no.1
    • /
    • pp.24-29
    • /
    • 2007
  • The main purpose of this study is to identify the shallow gas origin in the KSSM zone. Based on the results of gas composition and isotope in the headsapace gas, the shallow gas is mainly composed of methane and carbon and deuterium isotopes (${\delta}^{13}CCH_4$ and ${\delta}DCH_4$) of methane has ranged from -93.4%o to -70.9%, and from -228%o to -199%o in each. These results imply that shallow gas has predominately biogenic source by $CO_2$ reduction rather than thermogenic. The carbon isotopic separation (${\varepsilon}_c$) between methane and carbon dioxide $(CO_2)$ has a range of 54.4 to 72.2, it also supports biogenic origin of shallow gas.

  • PDF