• Title/Summary/Keyword: source frequency

Search Result 2,864, Processing Time 0.033 seconds

A Study on the Compensating System for the Acoustic Characteristics Caused by the Variation of Distance from Sound Source to Microphone (음원과 마이크로폰 사이의 거리변화에 의한 음향 특성 보정에 관한 연구)

  • Jeoung, Byung-Chul;Choe, Yoon-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.197-204
    • /
    • 2012
  • In this thesis, studied the method to minimize the changes in frequency response and level due to the variation of the distance from the source to the microphone. selecting three microphones (omni directional, cardioid, super cardioid) which are being used generally, frequency responses were measured in accordance with the distance changes. Gotten the difference from the reference as the result of measurement, changed responses for each frequency range were compensated in comparison of the original human vocal source. In low frequency range, the low frequency boost caused by the proximity effect and decrease in accordance with the distance were compensated. The variation in mid-frequency range is comparatively small, however since the mid-range is the most important part of the human vocal signal, were compensated the mid-frequency range in comparison of the reference. The human vocal signal variation in high frequency range is extremely small and the high frequency is compensated close to the original source without difficulty. Understanding the microphone characteristics and compensations, this study showed that the response can be maintain among the change of the distance from the source to the microphone.

A D-Band Integrated Signal Source Based on SiGe 0.18μm BiCMOS Technology

  • Jung, Seungyoon;Yun, Jongwon;Rieh, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.232-238
    • /
    • 2015
  • This work describes the development of a D-band (110-170 GHz) signal source based on a SiGe BiCMOS technology. This D-band signal source consists of a V-band (50-75 GHz) oscillator, a V-band amplifier, and a D-band frequency doubler. The V-band signal from the oscillator is amplified for power boost, and then the frequency is doubled for D-band signal generation. The V-band oscillator showed an output power of 2.7 dBm at 67.3 GHz. Including a buffer stage, it had a DC power consumption of 145 mW. The peak gain of the V-band amplifier was 10.9 dB, which was achieved at 64.0 GHz and consumed 110 mW of DC power. The active frequency doubler consumed 60 mW for D-band signal generation. The integrated D-band source exhibited a measured output oscillation frequency of 133.2 GHz with an output power of 3.1 dBm and a phase noise of -107.2 dBc/Hz at 10 MHz offset. The chip size is $900{\times}1,890{\mu}m^2$, including RF and DC pads.

Connected Characteristics for Small Generation Source of Low Voltage Model Grids (저압 모의선로에 소형발전원 연계시 특성)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha;Park, Tae-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.

Error Analysis in the Numerical Solution of Rayleigh Integral (Rayleigh 적분의 수치해에 관한 오차분석)

  • 이금원;김병기
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 1990
  • The numerical evaluation of Rayleigh's integral for the sound source reconstruction can be speeded up by the use of angular frequency propagation method and the FFT. However, are several source of errors involved during the reconstruction. Besides the aliasing error due to undersampling in space, the wrap around error. which is caused by undersampling the kernel functionin frequency domain, and windowing effect are present. We found that there is no replicated source problem and the windowing effect is due to the windowing the kernel function In frequency domain, and, xero padding is always required to improve the quality of reconstruction.

  • PDF

Marine Seismic Survey using a Multi-source System (다중음원 시스템을 이용한 해양 탄성파 탐사)

  • Kim, Hyun-Do;Kim, Jin-Hoo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.101-106
    • /
    • 2006
  • Digital technology has been applied to marine seismic survey to develop data processing technology and multi-channel marine seismic survey. In result, high-resolution marine seismic survey ended in a success. Surveys are conducted for various purposes using various frequencies of acoustic sources. A low frequency source is used for deeper penetration and a high frequency source is used for higher resolution survey. In this study, a multi-source system was used for multi-channel marine seismic survey to acquire seismic sections of both low and high frequencies. Variations of depth of penetration and resolution would be used to achieve more accurate analysis of formations. In this study, the multi-source system consists of Bubble Pulser (400 Hz) for low frequency source and Sparker (1.5kHz) for high frequency source.

  • PDF

Variable and Flexible Optical Frequency Comb Source using Dual Mach Zehnder Modulator and Phase Modulator

  • Naveed, Abbas;Choi, Bong-Soo;Tran, ThanhTuan;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.385-391
    • /
    • 2016
  • We demonstrated experimentally a variable optical frequency comb source using a cascaded dual parallel Mach Zehnder modulator (DPMZM) and a phase modulator (PM). With this simple configuration and applying low drive voltages, we generated variable comb source composed of spectral lines 3, 5, 7, 9 and 11 with 10-GHz frequency spacing, also generated 2 and 3 spectral lines with 20 GHz frequency spacing. The generated comb source maintains high spectral coherence across the entire bandwidth with good spectral flatness (within 1-dB for 2, 3, 5, 7 comb lines, within 2-dB for 9-comb lines and within 3-dB for 11 comb lines). The flat and variable comb source is mainly achieved by manipulating 6 operating parameters of DPMZM, setting RF amplifier gain, connected at phase modulator and phase shifters. Hence the method is simple and offers great flexibility in achieving flat and variable comb spectrum, which is experimentally demonstrated. This brings advantages of power efficiency due to low driving voltages, simplicity and cost effectiveness to the system.

Characteristics of Recent Occurrence Frequency of Asian dust over the Source Regions - Analysis of the dust Occurrences since 2002 (최근의 황사 발원지에서의 먼지 발생 특성-2002년 이후 먼지발생 경향 분석)

  • Lee, Jong-Jae;Kim, Cheol-Hee
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.493-506
    • /
    • 2008
  • In order to examine the variational features of Asian dust outbreak in recent years, observed WMO synop data were employed for the period from 1996 to 2007. We first divided Asian dust source regions into four subregions; 1) Taklamakan, 2) Gobi, 3) Inner Mongolia-Manchuria and 4) Loess, and the meteorogical variables such as wind speed, precipitation and threshold wind speed observed during the Asian dust outbreak period were compared with those during non-Asian dust period. The results showed that temporal variation of occurrence frequency of dust outbreak had a strong positive correlation with the frequency of strong wind speed and low precipitation in each of the 4 source regions. Spatial distributions of frequency of dust occurrence after 2002 showed increasing trend in Gobi and Inner Mongolia-Manchuria but decreasing trend in Loess region. This is showing a shift in main source region toward Northwest, especially since 2003.

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

A CMOS 180-GHz Signal Source with an Integrated Frequency Doubler

  • Kim, Jungsoo;Seo, Myeong-Gyo;Rieh, Jae-Sung
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.229-231
    • /
    • 2016
  • A 180-GHz signal source based on a 65-nm CMOS technology has been developed in this study. The 180-GHz signal source consists of a 90-GHz fundamental-mode Colpitts oscillator and a 180-GHz frequency doubler. A coupled-line is employed to couple two oscillator cores for generating a differential signal, which is delivered to the input of the differential-mode doubler. The fabricated signal source operates from 181.2 to 182.4 GHz with output power varying from -15.3 to -10.8 dBm. The peak output power was -10.53 dBm at 181.3 GHz with a DC power consumption of 42 mW, and the associated phase noise was -71 dBc/Hz at 1 MHz offset.

Estimation of Ionospheric Delays in Dual Frequency Positioning - Future Possibility of Using Pseudo Range Measurements -

  • Isshiki, Hiroshi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.185-190
    • /
    • 2006
  • The correct estimation of the ionospheric delays is very important for the precise kinematic positioning especially in case of the long baseline. In case of triple frequency system, the ionospheric delays can be estimated from the measurements, but, in case of dual frequency system, the situation is not so simple. The precision of those supplied by the external information source such as IONEX is not sufficient. The high frequency component is neglected, and the precision of the low frequency component is not sufficient for the long baseline positioning. On the other hand, the high frequency component can be estimated from the phase range measurements. If the low frequency components are estimated by using the external information source or pseudo range measurements, a more reasonable estimation of the ionospheric delays may be possible. It has already been discussed by the author that the estimation of the low frequency components by using the external information source is not sufficient but fairly effective. The estimation using the pseudo range measurements is discussed in the present paper. The accuracy is not sufficient at present because of the errors in the pseudo range measurements. It is clarified that the bias errors in the pseudo range measurements are responsible for the poor accuracy of the ionospheric delays. However, if the accuracy of the pseudo range measurements is improved in future, the method would become very promising.

  • PDF