• Title/Summary/Keyword: sound insulation

Search Result 453, Processing Time 0.024 seconds

Heavy-impact sound insulation performance according to the changes of dry flooring structure in wall structure

  • Cho, Jongwoo;Lee, Hyun-Soo;Park, Moonseo;Lim, Hohwan;Kim, Jagon
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.89-98
    • /
    • 2017
  • The floor heating method generally uses a wet construction method including the installation of resilient material, lightweight foam concrete, heating piping, and finishing mortar. Such a wet construction method not only delays other internal finishing processes during curing period for two mortar pouring process, but also has a disadvantage that it is difficult to replace the floor heating layer when it deteriorated because it is integrated with the frame. Dry floor heating construction method can be a good alternative in that it can solve these defects. Conversely, when it applied to the wall structure that is vulnerable to the interlayer noise compared with the column-beam structure, the question about the heavy-impact sound(HIS) insulation performance is raised. Therefore, conventional dry floor heating method is hard to apply to the wall structure apartments. Therefore, for the purpose to improve the applicability of dry floor heating method in wall structure apartments, this study investigated the change of floor impact sound, especially HIS insulation performance which is one of the required performance for the floor structure. This study tried to examine whether the change of heavy-impact sound pressure level(SPL) shows a tendency at the significant level according to the shape and mass of the floor structure. Through filed experiments on wall structure apartment, this study confirmed that the form of the raised floor shows better HIS insulation performance than the fully-supported form. In addition, it was also confirmed that the HIS insulation performance increases with the mass on the upper part. Moreover, this study found the fact that a mass of about 30 kg/m2 or more should be placed on the upper structure to reduce the heavy-impact SPL according to the bang machine measuring method. Although this study has a limit due to insufficient experiment samples, if the accuracy of this study is increased, it will contribute to the diffusion of dry floor heating by setting the HIS insulation performance target and designing the dry floor heating structure that meets the target.

  • PDF

Performance Evaluation of the Floor Impact Sound Insulation in Steel Framed Modular House (강재프레임 모듈러주택의 바닥충격음 성능평가)

  • Chun, Young-Soo;Bang, Jong-Dae;Kim, Gap-Deug;Yoo, Song-Lee
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.81-89
    • /
    • 2014
  • This paper presents various attempts to secure the floor impact sound insulation performance on the dry floor system of steel framed modular house that lately attracted domestic attention. Test results show that in the condition of using dry floor system of D31(D32), the light-weight impact noise performance records the top level in the floor impact sound insulation performance grading system. the heavy-weight floor impact noise performance meets the minimum sound level limit in the floor impact sound insulation performance grading system that enacted regulation on housing construction standards.

Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box (차음상자와 전자청진기로 기록된 장음에 의해서 깨어 있는 흰쥐의 위수축력 측정)

  • Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.439-447
    • /
    • 2014
  • Objectives: The aim of this study was to investigate whether 1) variation of bowel sounds recorded stably through an electronic stethoscope in a sound insulation box can be related with that of gastric contraction and 2) if they are thus useful tool in the measurement of the gastric contractility in awake rats or not. Methods: Electrical potentials of both electronic stethoscope of bowel sound and force transducer were recorded simultaneously and continuously in the sound insulation box for the starting 30 min of basal state, and then 30 min of 0.2 ml normal saline administration, finally 30 min of 0.2 ml mosapride citrate solution (100 mg/Kg) in rats. Each motility index of normal saline or mosapride citrate treatment was presented with ratio against the basal state by using integrated electrical potentials. Results: A pattern of significance of gastric contractility between bowel sound and force transducer was showed analogously. Conclusions: The amplitude of bowel sounds recorded by the electronic stethoscope related with the intensity of gastric contractions. This confirms that a sound insulation box and electronic stethoscope are useful tools in the measurement of the gastric contractility of awake rats.

A Study on the Experimental Sound Transmission Loss of Wall-Body in Song Practice Room (노래연습실 벽체의 투과손실에 관한 실험적 연구)

  • Yun, Jae-Hyun;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.221-225
    • /
    • 2007
  • Recently, on account of stress relief and settlement of a healthy drinking culture, many people are visiting a song practice room. In case of such song practice room, since the mechanical voice through a loud accompaniment-music and microphone is on using, there has made a very loud noise, and it influences a lot to the adjacent other space and song practice room booth. Consequently, from the designing stage an efficient measures for soundproof and sound-insulation should be arranged. However, as most of the song practice room wall-bodies that already built up or under construction step were constructed merely with consideration on an interior-wise factor only, it is suffering at the soundproof and sound-insulation. Reflecting such viewpoint, this Study has measured Sound Transmission Loss on the subject for the song practice room wall-body recently built up, and based on the actually measured data, by practice of comparison?analysis on it using various evaluation methods, would intends to present a fundamental material for establishment an efficient sound-insulation measure.

  • PDF

Experimental discussion on the installation of filler wall for sound insulation measurements of shipboard windows (선박용 창의 차음성능 측정용 충진벽체 설치에 관한 실험적 고찰)

  • Kim, Sang-Ryul;Kang, Hyun-Ju;Kim, Hyun-Sil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.276-279
    • /
    • 2008
  • In order to measure sound transmission loss (STL) of a shipboard window of small size, a special partition is built into the test opening between two reverberation rooms and the specimen is placed in that partition. For high sound insulation, the filler wall often has multi-layered structure such as double-brick wall or buckhead structure with thick steel plate, absorptive material, and sandwich panels. This paper discusses the installation method of a multi-layered filler wall that consist of gypsum boards, lead plates, and glass wool. The experimental results of various wall structures are introduced. The comparison between the results show that the sound bridge effect plays a significant role in lowering the maximum STL of the filler wall. It is also found that the higher the sound insulation performance of the filler wall is, the more important the franking transmission through other side wall of the test facility is.

  • PDF

Experimental evaluation of sound Insulation performance of ceiling panels (천장재 차음성능의 실험 평가)

  • 강현주;김상렬;김재승;김현실;김봉기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1067-1070
    • /
    • 2002
  • This paper deals with the factors affecting measurement of sound insulation performance of the ceiling panels. The factors to be experimently examined are as follows: sound diffuseness of the test room by investigating sound pressure distribution, Reverberation time, and influence of speaker location on measured results. Based on the investigation of sound pressure distribution over measuring points, it can draw a conclusion that rectangular shaped rooms as test rooms have a serious problem associated with the diffuse sound field.

  • PDF

A Study on the Standard and Classification of Impact Sound Insulation Performance for Apartment House(II) (바닥 衝擊音 遮音性能基準 및 等級化에 관한 硏究(Ⅱ))

  • Kim, Sun-Woo;Son, Chul-Bong;Song, Yong-Sik;Jang, Gil-Soo;Lee, Tae-Kang;Kook, Chan;Kim, Jae-Soo;Han, Myung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.5-17
    • /
    • 1990
  • This study aims to establish the appropriate class and standards of sound insulation performance, which are suitable for domestic conditions. For, these purpose, field surveys were conducted, correlationship between subjective response and impact sound insulation performance and then, the applicability of ISO and JIS evaluation method was reviewed. As a result, the JISs method is more advisable than the ISO to evaluate Impact sound insulation performance of domestic apartment house and it is desirable to use both light and heavy weight source (tapping machine, tire) as standard impact sources. And, whether including 63Hz bandwidth or not, the difference was recognized very small in calculating impact sound insulation index of JIS A 1419.

  • PDF

A Study on the factor of flanking transmission in the Wall (벽체 우회전달음 영향요소에 관한 연구)

  • Chung, J.Y.;Lee, S.H.;Kim, K.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.380-383
    • /
    • 2006
  • This study examines the influence factor of flanking transmission in the wall. Generally, there is the difference of airborne sound isolation between laboratory and field test. The purpose of this study is examing the cause of droping sound insulation performance in the field and searching the method of improving sound insulation performance. First, we measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the flanking transmission and solid transmission. For the flanking transmission am the wall, we used intensive method. So, we found the influence of solid transmission.

  • PDF

Development of a Simplified Test Apparatus for Measuring Sound Transmission Loss (간이 차음시험장치 개발)

  • 이해성;전오성;강현주;김봉기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.892-897
    • /
    • 2003
  • This study deals with the performance of a simplified test apparatus for measurement of sound insulation of panels. In order to investigate its performance, results from experiment and theory of the sound transmission loss for single and double panels are compared. Comparative results show that in evaluation of the sound insulation performance, the test apparatus has a cumbersome problem at the low frequency region, i.e. below 315 ㎐, presumably because of the poor diffuse sound field in the chambers. Meanwhile at the high frequency, it shows a considerable results comparable to the theoretical prediction. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF

Sound Insulation Performance of the Layered Structure of the Next Generation High Speed Train (차세대 고속철도 차량 적층 구조의 차음성능)

  • Lee, Jung-Hyeok;Kim, Seock-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.326-331
    • /
    • 2011
  • Aluminum extruded panel used in a high speed train shows high stiffness, however, its sound insulation performance is remarkably decreased by local resonance phenomena. In this paper, improvement strategy of the sound insulation performance is proposed for the floor extruded panel used in HEMU-400x, 400km/h class next generation high speed train under development, and the improvement effect is verified by experiment. Aluminum extruded panel specimen for the floor is manufactured and urethane foam is installed in the core of the panel. Based on ASTM E2249-02, intensity transmission loss is measured and the improvement effect in local resonance frequency band is verified. Finally, improvement effect of the sound insulation performance is estimated on the layered floor structure including the foamed aluminum panel.

  • PDF