• 제목/요약/키워드: solenoid magnet

검색결과 74건 처리시간 0.027초

3자유도 모터 제어를 위한 철심 솔레노이드 특성의 실험적 해석에 관한 연구 (A Study of the Iron-Core Solenoid Analysis for 3 D.O.F. Motor Control with Experimental Method)

  • 백윤수;박준혁
    • 대한기계학회논문집A
    • /
    • 제25권9호
    • /
    • pp.1334-1340
    • /
    • 2001
  • In this paper, the experimental modeling of the force between permanent magnet and iron-core solenoid is suggested for more accurate control of 3 D.O.F. motor using the electromagnetic force. In the case of iron-core solenoid, the general equation of solenoid cant be used simply because of its nonlinearity. Therefore, the magnetic flux density is estimated through the concept of equivalent permanent magnet. The force distribution between permanent magnet and iron-core solenoid is more dependent on the magnetization of iron core caused by the permanent magnet than any other parameters. Therefore, the equation of the force estimation between these magnetic systems can be modeled by the experimental function of the magnetization of iron core. Especially, if the distance between iron-core solenoid and permanent magnet is far enough, the force equation through experiment can be expressed from only the current of coil and the distance between iron-core solenoid and permanent magnet. It means that Coulombs law can be used for magnetic systems and it is validated through the experiment. Therefore, force calibration is performed by the concept of Coulombs law.

Bi-directional Actuator using a permanent magnet and solenoid

  • Kim, K.H.;Kim, D.M.;Lee, S.Q.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.98.1-98
    • /
    • 2001
  • An actuator using a permanent magnet and solenoid is proposed and designed in this paper. Its design concept is composed of a driving force generation, a guide mechanism, and a symmetric structure. At first, Driving Force generation uses a concept that is a change efflux by using a permanent magnet and solenoid. A permanent flux is generated by a permanent magnet. Changeable flux is created by a variable current flowing through coil such the solenoid. The direction of this flux is changed due to current flowing through coils. The combination of permanent and changeable fluxes make various flux densities between yokes of moving part and fixed yokes. And then, the flux densities create forces(F), which are used to drive this actuator, in lower and upper gap. In this actuator ...

  • PDF

Comparison analysis of superconducting solenoid magnet systems for ECR ion source based on the evolution strategy optimization

  • Wei, Shaoqing;Lee, Sangjin
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.36-40
    • /
    • 2015
  • Electron cyclotron resonance (ECR) ion source is an essential component of heavy-ion accelerator. For a given design, the intensities of the highly charged ion beams extracted from the source can be increased by enlarging the physical volume of ECR zone [1]. Several models for ECR ion source were and will be constructed depending on their operating conditions [2-4]. In this paper three simulation models with 3, 4 and 6 solenoid system were built, but it's not considered anything else except the number of coils. Two groups of optimization analysis are presented, and the evolution strategy (ES) is adopted as an optimization tool which is a technique based on the ideas of mutation, adaptation and annealing [5]. In this research, the volume of ECR zone was calculated approximately, and optimized designs for ECR solenoid magnet system were presented. Firstly it is better to make the volume of ECR zone large to increase the intensity of ion beam under the specific confinement field conditions. At the same time the total volume of superconducting solenoids must be decreased to save material. By considering the volume of ECR zone and the total length of solenoids in each model with different number of coils, the 6 solenoid system represented the highest coil performance. By the way, a certain case, ECR zone volume itself can be essential than the cost. So the maximum ECR zone volume for each solenoid magnet system was calculated respectively with the same size of the plasma chamber and the total magnet space. By comparing the volume of ECR zone, the 6 solenoid system can be also made with the maximum ECR zone volume.

초전도 MRI 마그네트 국산화 개발 (The Domestic Development of a Superconducting MRI Magnet)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

중자장급 보급형 국산 초전도 MRI 마그네트 개발 (The Development of Popular type Domestic Superconducting MRI Magnet with Middle Magnetic Field Range)

  • 배준한;고락길;심기덕;진흥범;조전욱;이언용;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.22-25
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

자동차 연료펌프 구동용 보이스 코일 전자기 엑츄에이터의 설계 및 해석 (Design and Analysis of Voice Coil Actuator to Drive Fuel Pump in Automobile)

  • 박세명;김진호;배철호
    • 한국자기학회지
    • /
    • 제20권6호
    • /
    • pp.234-238
    • /
    • 2010
  • 캠샤프트의 구동력을 활용한 기계식 연료펌프 시스템을 대체할 솔레노이드 격막 연료펌프는 최근 각광받고 있는 고효율 그린카 부품 중 하나이다. 하지만 솔레노이드 격막 연료펌프의 경우 왕복운동에 필요한 자속을 오직 솔레노이드에 의존하므로 전력소비가 비교적 큰 단점이 있다. 따라서 본 연구에서는 전력소모를 최소화 하기 위하여 영구자석형 VCA 연료펌프 시스템을 제안한다. 또한 상용전자기해석소프트웨어인 MAXWELL을 활용하여 유한요소 해석을 통해 기존의 솔레노이드 격막 펌프와의 전력소모 및 동적 성능을 비교 분석한다.

비정질 다이아몬드 코팅을 위한 자장여과 아크소스의 동작 특성에 관한 연구 (Operation Characteristic of Filtered Vacuum Arc Source for Amorphous Diamond Coating)

  • 김종국;이구현
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.147-157
    • /
    • 2000
  • The filtered vacuum arc source (FVAS), which is adopted by magnetic filtering methode to remove the macro-particle in vacuum arc plasma, was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were consisted of one permanent magnet, one magnetic yoke and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Graphite was used as the cathode material to coat the amorphic diamond film and its diameter was 80 mm. The amorphic diamond film attracts much attention due to its excellent mechanical, optical and tribological properties suitable for wide range of applications. The effects of solenoid magnet in plasma extraction were studied by computer simulation and experiment using Taguchi's method. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. Optimum deposition condition was obtained when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, and 5 A, respectively.

  • PDF

A Single DOF Magnetic Levitation System using Time Delay Control and Reduced-Order Observer

  • Park, Jung-Soo;Baek, Yoon-Su
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1643-1651
    • /
    • 2002
  • Magnetic levitation systems are required to have a large operating range in many applications. As one method to solve this problem, Time Delay Control (TDC) is applied to a single-axis magnetic levitation system in this paper A reduced-order observer is utilized to estimate states excluding measurable states in the control law. The system consists of a square air-core solenoid and a circular permanent magnet attached on a plastic ball. Theoretical magnetic forces of the system are obtained on the basis of the location of the magnet around the solenoid. The magnetic levitation force is obtained by the experiment, and then compared with the theoretical one. As the results of the control experiments, the nonlinear controller (TDC : 1-2 ㎜) has a larger operating range than the linear controller (PD control : 1-1.4 ㎜), and is superior to linear. control in the robustness to the modeling uncertainty and the performance of the disturbance rejection.

고전압 차단기용 솔레노이드의 특성해석 (Characteristics Analysis of the Solenoid for High-Voltage Circuit Breaker)

  • 윤소남;류재섭;함영복;노종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.382-385
    • /
    • 2003
  • In this paper, the solenoid for high-voltage circuit breaker which is composed of bobbin, solenoid coil, stationary core and plunger was studied. The solenoid is made of a soft magnetic iron bar with a large number of coil windings. when an electric current passes through this, this stationary core becomes the strong magnet used for hydraulic and pneumatic valve of a solenoid operated valve. For the performance evaluation of the solenoid for high-voltage circuit breaker, electromagnetic characteristics and dynamic characteristics were analyzed. And, the parameters which is related to performance improvement were investigated.

  • PDF