• Title/Summary/Keyword: solar thermal

Search Result 1,711, Processing Time 0.025 seconds

Study on Improvement of Thermal Environment by Green Roof Systems on RC Building - utilization of solar insulating block and the grass - (옥상녹화에 따른 콘크리트 건축물의 열환경 개선효과 -일사차폐블록과 잔디를 대상으로-)

  • Park, Chanpil;Furukawa, Nobuhisa
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Caused on the excessive heat accumulation of concrete material, the indoor thermal environment of reinforced concrete building is so bad in Okinawa. As the interruption of solar radiation could be one of the methods to improve it, the purpose of this study is to find out the effect of adopting solar radiation interrupting materials -Solar insulating block, Grass, and both of them- for the improvement of thermal environment. As the result, it was found that grass on the solar insulating block which has an air layer obviously improved the indoor thermal environment of RC building which was applied to. And it was found that the systems have an effectuality on heat island phenomenon simultaneously. It could be proposed as a good system which improve the indoor thermal environment of the existent houses.

Thermal Performance of Solar Thermal System by On-Off Differential Temperature of Differential Temperature Controller (차온제어기의 On-Off 온도설정에 따른 태양열 시스템 열성능)

  • Shin, U-Cheul;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • On-off differential controller is one of the very important components which affect the system performance of the active solar thermal system. In this study, analyses were made regarding the influence of "on-off" setting temperature on the system efficiency and on the electrical consumption by circulation pump. This study was performed by experiment as well as the computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results. As a results, the turn off temperature(${\Delta}T_{off}$) is much more influence than the turn on temperature(${\Delta}T_{on}$) on the system efficiency. It is more clear and sensitivity in winter season. Finally the optimum on-off setting value and the system on-off pattern according to the several different kind of system was also represented.

An Analysis of the Thermal Performance of the Glass Evacuated Tube Solar Collector (진공관형 태양열 집열기의 열성능 해석)

  • Kim, Y.;Seo, T.B.;Kang, Y.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.43-49
    • /
    • 2003
  • The thermal performance of the glass evacuated tube solar collector is numerically investigated. The glass evacuated tube solar collector consists of a two-layed glass tube, a copper tube, and the working fluid. The length and the diameter of the glass tube are 1,200mm and 38mm, respectively. The diameter, thickness, and length of the copper tube and the flow rate of air are considered as the important design and operating parameters of the collector. The effect of these parameters on the thermal performance of the collector are investigated. The results show that as the diameter, the thickness, and the length of the copper tube increase and the flow rate of the air decreases, the thermal performance and the outlet mean temperature increase.

Thermal Characteristics Evaluation of Concentrated Hybrid Panel with cooling system on PV module (PV모듈의 냉각장치를 적용한 집속형 복합패널의 집열 특성 평가)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.47-52
    • /
    • 2005
  • Normally if sunlight is directed on a solar cell without any increasing in temperature, the amount of absorption energy per unit area of each cell is increasing. In a silicon solar cell. however, cell conversion efficiency decreases with the increase of temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. We tried to design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect and use thermal energy more effectively. We compared performance of this new hybrid panel with current thermal panel. We also evaluated conversion efficiency, thermal capacity and confirmed cooling effects from thermal absorption efficiency.

Analysis of the Thermal Dome Effect from Global Solar Radiation Observed with a Modified Pyranometer

  • Zo, Ilsung;Jee, Joonbum;Kim, Buyo;Lee, Kyutae
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.263-270
    • /
    • 2017
  • Solar radiation data measured by pyranometers is of fundamental use in various fields. In the field of atmospheric optics, the measurement of solar energy must be precise, and the equipment needs to be maintained frequently. However, there seem to be many errors with the existing type of pyranometer, which is an element of the solar-energy observation apparatus. In particular, the error caused by the thermal dome effect occurs because of the thermal offset generated from a temperature difference between outer dome and inner casing. To resolve the thermal dome effect, intensive observation was conducted using the method and instrument designed by Ji and Tsay. The characteristics of the observed global solar radiation were analyzed by classifying the observation period into clear, cloudy, and rainy cases. For the clear-weather case, the temperature difference between the pyranometer's case and dome was highest, and the thermal dome effect was $0.88MJ\;m^{-2}\;day^{-1}$. Meanwhile, the thermal dome effect in the cloudy case was $0.69MJ\;m^{-2}\;day^{-1}$, because the reduced global solar radiation thus reduced the temperature difference between case and dome. In addition, the rainy case had the smallest temperature difference of $0.21MJ\;m^{-2}\;day^{-1}$. The quantification of this thermal dome effect with respect to the daily accumulated global solar radiation gives calculated errors in the cloudy, rainy, and clear cases of 6.53%, 6.38%, and 5.41% respectively.

The Experimental Performance of Rectangular Tube Absorber PV/Thermal Combined Collector Module (사각튜브부착형 흡열판을 적용한 Unglazed PVT 복합모듈의 열적 전기적 성능분석)

  • Jeong, Seon-Ok;Chun, Jin-Aha;Kim, Jin-Hee;Kim, Jun-Tae;Cho, In-Soo;Nam, Seung-Baeg
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.87-92
    • /
    • 2011
  • The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. A photovoltaic-thermal(PVT)module is a combination of PV module with a solar thermal collector which forms one device that converts solar radiation into electricity and heat simultaneously. The performance of the PV/Thermal combined collector module is directly influenced by solar radiation that also has an effect on PV module temperature. It is also has believe that the energy performance of PV/T collector is related to absorber design as well as PV module temperature. The existing study has been paid to the PV/Thermal combined collector module with circle tube absorbers. The aim of this study is to analyze the experimental performance of the PV/Thermal combined collector rectangular tube absorbers according to solar radiation. The experimental result show that the average thermal and electrical efficiencies of the PVT collector were 43% and14.81% respectively. Solar radiation is one of the most influential factors to determine the energy performance of PVT collector, but from a certain level of solar radiation the PVT collector receives on, its efficiencies began to decrease.

  • PDF

Thermal Characteristics Investigation of 6U CubeSat's Deployable Solar Panel Employing Thermal Gap Pad (열전도 패드가 적용된 6U 큐브위성용 태양전지판의 열적 특성 분석)

  • Kim, Hye-In;Kim, Hong-Rae;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.3
    • /
    • pp.51-59
    • /
    • 2020
  • In the case of cubesat, a PCB-based deployable solar panel advantageous in terms of weight reduction and electrical circuit design is widely used considering the limited weight and volume of satellites. However, because of the low thermal conductivity of PCB, there is a limit relative to heat dissipation. In this paper, the thermal gap pad is applied to the contact between the PCB-based solar panel and the aluminum stiffener mounted on the outside of the panel. Thus, the heat transfer from the solar cell to the rear side of the panel is facilitated. It maximizes the heat dissipation performance while maintaining the merits of PCB panel, and thus, it is possible to improve the power generation efficiency from reducing the temperature of the solar cell. The effectiveness of the thermal design of the 6U cubesat's deployable solar panel using the thermal gap pad has been verified through on-orbit thermal analysis based on the results, compared with the conventional PCB-based solar panel.

Analysis of the Irradiated Solar Heat Effect on Indoor Thermal Environment of the ToP Floor Units of Apartment Houses in the Summer - On Condition that All Openings of the Units are Closed - (공동주택의 하절기 개구부 밀폐 시 지붕면 일사수열이 최상층 실내온열환경에 미치는 영향 분석)

  • Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.45-53
    • /
    • 2004
  • In the summer, the irradiated solar heat gain through the roof has an effect on the thermal environment of the top floor units of apartment houses. This paper investigated the differences of the indoor air temperature and thermal comfort index between the top floor unit and the middle floor unit by measuring them at the sample houses. The purpose of this paper is to provide quantitative data about the irradiated solar heat gain during the summertime through the roof of an apartment house and these data to be the source to reevaluate the appropriate roof insulation efficiency. From this study, we obtained the brief results as follows. Indoor air temperature at the top floor unit is $1.2\sim2.2^{\circ}C$ higher than that of middle floor unit. The evaluation of the indoor thermal comfort index at each sample rooms reveals notable thermal differences between the two units. Top floor units need more cooling load during the summertime compared to middle floor units. Therefore, solutions to reduce solar Heat gain at top floor units to be considered.

A Study on Thermal Performance of Heat Pipes with Different Condenser Shape for Evacuated Tubular Solar Collector (태양열 집열기용 히트파이프 응축부 형상 변화에 따른 열성능 연구)

  • Kwak, Hee-Youl;Joo, Hong-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.28-33
    • /
    • 2008
  • The purpose of this study was experimentally to investigate thermal performance of heat pipe for evacuated tubular solar collector. Two sets of evacuated tubular solar collector with different condenser shape of heat pipe were prepared. The experiments were performed under the same operating condition with an indoor testing apparatus. Also, the experiments were carried out various testing conditions including inclination, flow rate, and incident heat flux. The results of thermal performance of collector with enlarged condenser showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_RU_L$ was -2.0086 at $40^{\circ}$. And the results of thermal performance of collector with straight condenser showed that $F_R({\tau}{\alpha})$ was 0.6233 and $F_RU_L$ was -1.4996 at the same inclined angle.

Solar Thermal Hybrid Power Generation;technology review and system design (태양열복합발전 기술개발 동향 및 설계)

  • Kim, Jin-Soo;Kang, Yong-Heack;Lee, Sang-Nam;Yun, Hwan-Ki;Yu, Chang-Kyun;Kim, Jong-Kyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.684-687
    • /
    • 2007
  • Research on the solar thermal hybrid power generation technology which uses solar thermal chemical reaction has been carried out in KIER, The research covers development of solar concentration system and solar reactor for methane steam reforming reaction. This paper introduces a brief review and prospects of oversea's researches in similar areas and KIER's research progresses up to now.

  • PDF