• Title/Summary/Keyword: solar heat system

Search Result 792, Processing Time 0.03 seconds

The Development of monitoring system for demonstration research of solar hot water heater for dwellings (실증연구를 위한 주택용 태양열 온수기 모니터링 시스템 개발)

  • 양동조;김재열;한재호;송경석;김우진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.156-161
    • /
    • 2004
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

The Study on Efficiency Improvement of a Thermal Storage Tank for Solar Combined Heating System (태양열원 난방기의 수축열조 효율개선에 관한 연구)

  • Ryu, Nam-Jin;Han, Yu-Ry;Park, Youn-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.43-49
    • /
    • 2007
  • This study is conducted to improve the efficiency of a thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from the solar or the others heat sources. However, it has difficulties in storing heat with nonuniform temperature through the entire tank with respect to the vertical direction, This study is focused on the thermal stratification to improve thermal comfort for the resident in house. To enhance temperature stratification of the tank, a distributor was designed and installed in the middle of the storage tank vertically. The vertically designed distributor could supply the return water with stratified temperature in the storage tank with respect to the height. The water velocity from the distributor hole is the same with the other outlet in the distributor. However, gravity effect on the flow in the storage tank is much higher than that of the velocity effect due to that Froude Number is less than 1. During the heat charging process in the storage tank, temperature maintained with little difference with respect to the height. However the charging process takes long time to get a effective temperature for the heating or hot water supply because of all of water in the storage tank needs to be heated.

The Application and Evaluation of Heating and Cooling System by Seawater Heat Source for Research Center Building in Jeju (제주지역 연구소 건물의 해수열원 냉난방시스템 적용 및 평가)

  • Park, Jin-Young;Kim, Sam-Uel;Chang, Ki-Chang
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.26-31
    • /
    • 2013
  • Use of heat from seawater could be different from the weather conditions of a coastal city and seawater temperatures near the city. It will be a good option to use surface layer water with Heat Pump system for using seawater cooling/heating in Jeju. The study investigates the proper depth for seawater heat gain of Jeju area in Korea. Sampling points are 0, 10, 20, 30m from the surface of the Sea. Seawater temperature does not change significantly according to the depth in winter, while the temperature is quite different according to the depth in summer. In this study, it is analyzed to compare existing system and seawater heat source system for target buildings on Jeju. And this systems are calculated a initial cost.

Thermal Performance Analysis and Optimization of Two-dimensional Trombe Wall Solar System (2차원 축열벽형 태양열시스템의 열성능해석 및 최적화)

  • 이원근;유성연;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1609-1620
    • /
    • 1993
  • A Study on the trombe wall system, a kind of passive solar systems, has been performed numerically. The system is treated as a two-dimensional steady turbulent natural convection including constant heat source per unit area. The numerical code, "PHOENICS, " was employed to analyze this conduction-convection conjugated heat transfer. The general mode of the flow field was examined, and the exchange of mass between two recirculating flows is found to be the major mechanism of the heat transfer. It is shown that the performance is affected by the changes in the geometrical factors-the thickness of the wall, the width between the windowand the wall, and size of the vents. Further analysis has been performed to show the optimal geometry with regard to the last two factors.o factors.

Thermal Test of High-Temperature Solar Concentrating System for Hybrid Power Generation (복합발전용 고온 집광시스템의 집열 특성 분석)

  • Kim, Jin-Soo;Lee, Sang-Nam;Kang, Yong-Heack;Yun, Hwan-Ki;Yun, Chang-Kyun;Kim, Jong-Kyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.580-583
    • /
    • 2006
  • A small-scale solar concentrating system was developed and demonstrated for supplying process heat required in solar thermo chemical reaction. The concentration system consists of a heliostat equipped with a solar tracking device and a dish concentrator. From the initial thermal test of the concentrating system it was found that the system works very well with around 500-600 concentration ratio capable of supplying about 3kW therml energy to the reactor. Once the concentration system was turned on, the reactor temperature rapidly increased over $1,000^{\circ}C$ and could be maintained high enough for solar chemical reaction.

  • PDF

Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System (물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구)

  • Hong, Boo-Pyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

The Performance and Efficiency Analysis of a PVT System Compared with a PV module and a Solar collector (PVT 시스템의 PV 모듈 및 태양열 집열기 대비 성능 및 효율 비교분석)

  • Euh, Seung-Hee;Lee, Jeong-Bin;Choi, Yun-Sung;Kim, Dae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.1-10
    • /
    • 2012
  • A photovoltaic/thermal (PVT)solar system is the solar technology that allows for simultaneous conversion of solar energy into both electricity and heat. This paper compared the performance of PVT system with a conventional PV module and solar collector and analyzed electrical and thermal efficiency of PVT system in terms of solar irradiance and inlet temperature of the working fluid. Based on the experimental data, thermal and electrical efficiencies of he glazed PVT system were57.9% and14.27% under zero reduced temperature condition which were lower by 13.6% than the solar thermal absorber plate and by 0.08% than the PV module respectively. For the unglazed PVT system it had lower thermal efficiency than the solar thermal absorber plate but higher electrical performance than the PV module due to the cooling effect by the working fluid. However, total efficiency of the glazed PVT system was72.2% which was higher than combined efficiencies of the solar collector and PV module. Besides, total efficiency of the PVT system would be much higher if calculated based on unit area.

The Basic Study on Economic Evaluation of Distributed Energy System Installed in Hospital (병원건물 분산에너지시스템 도입에 따른 경제성분석)

  • Hong, Won-Pyo;Kim, Hyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1136_1138
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that burn gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

The Basic Study on Economic Evaluation of Micro-turbine and Alternative Energy system Installed in Hospital (병원건물의 마이크로터빈과 신재생에너지도입에 따른 경제성평가 기초연구)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.439-444
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of. solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System (공기순환구조를 갖는 축열지붕의 열전달해석)

  • Shin, U.C.;Park, S.H.;Baek, N.C.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF