• 제목/요약/키워드: soil cover depth

검색결과 88건 처리시간 0.024초

Reliability of underground concrete barriers against normal missile impact

  • Siddiqui, N.A.;Khan, F.H.;Umar, A.
    • Computers and Concrete
    • /
    • 제6권1호
    • /
    • pp.79-93
    • /
    • 2009
  • In the present paper, a methodology has been presented for the reliability assessment of concrete barriers that lie at a certain depth in the soil, and a missile (a rigid projectile) impacts the top of the soil cover normally, and subsequently after penetrating the soil cover completely it hits the barrier with certain striking velocity. For this purpose, using expressions available in the literature, striking velocity of missile at any depth of soil has been derived and then expressions for the depths of penetration in crater and tunnel region of concrete barrier have been deduced. These depths of penetration have been employed for the derivation of limit state functions. Using the derived limit state functions reliability assessment of underground concrete barrier has then been carried out through First Order Reliability Method (FORM). To study the influence of various random variables on barrier reliability, sensitivity analysis has also been carried out. In addition, a number of parametric studies is conducted to obtain the results of practical interest.

Impact of parthenium weed invasion on plants and their soil seedbank in a subtropical grassland, central Nepal

  • Khatri-Chettri, Jyoti;Rokaya, Maan Bahadur;Shrestha, Bharat Babu
    • Journal of Ecology and Environment
    • /
    • 제46권1호
    • /
    • pp.8-17
    • /
    • 2022
  • Background: Parthenium hysterophorus L. (Asteraceae; hereafter Parthenium) is an invasive alien species of global significance because of its' negative ecological and socioeconomic impacts. This species is spreading rapidly from lowland Tarai to Middle Mountain regions in Nepal. In the present study, we analyzed the impacts of Parthenium on plant community composition including their soil seedbank in subtropical grasslands located in central Nepal. Data was collected in a 10 m long transects passing through areas of high (> 90% cover), medium (40%-60%) and low (< 10%) levels of Parthenium cover using a plot of 1 m2. Altogether, we sampled 90 plots in 30 transects. Seedling emergence method was used to estimate soil seedbank density in the soil samples (0-10 cm depth) collected from the plots with high Parthenium cover. Results: There was no significant difference in the plant species richness at different levels of Parthenium invasion whereas there was a significant change in the species composition of above ground flora due to Parthenium invasion. There was also a significant difference in species composition between soil seedbank and aboveground flora in the highly invaded plots. Parthenium was the most dominant in soil seedbank, contributing 65% to the total soil seedbank. Conclusions: Our study suggests that Parthenium has considerable negative impact on the native grassland flora, and the dominance of Parthenium in the soil seedbank means there is a challenge for its management. It also suggests the need of monitoring the soil seedbank dynamics while managing Parthenium weed.

A Study on Behavioral Characteristics of Track Roadbed according to Steel Pipe Press-in Excavation during Construction of Underground Railway Crossing

  • Kim, Young-Ha;Eum, Ki-Young;Kim, Jae-Wang
    • International Journal of Railway
    • /
    • 제6권2호
    • /
    • pp.69-77
    • /
    • 2013
  • In this study, numerical analysis and model experiments were conducted to analyze behavioral characteristics acting on the track roadbed with excavation through steel pipe injection, a non-exclusive method of crossing construction under railroad as primary target. In model experiments that simulate injection excavation behaviors with an increase in the depth of soil cover, the upper displacement was measured by construction of the first and the second pipes in order to predict actual behaviors, and the behavior characteristics were verified through numerical analysis. The investigation results showed that surface displacement was smaller under the condition of higher soil cover. In the case of injecting two pipes, when the first pipe was injected, deformation of the surface increased linearly in both settlement and uplift experiments. However, when the second pipe was injected, the amount of change was found to be very small due to the relaxation and plastic zones around the first pipe. In addition, the results of numerical analysis on the same cross section with the model experiment found that the results of investigation into settlement ratio and volume loss were in very good agreement with those obtained by the model experiment.

타이어셀로 보강된 지반의 거동에 대한 수치모델링 (Numerical Modeling of Reinforced Soil with Waste Tirecell)

  • 윤여원;견광수;윤길림
    • 한국지반환경공학회 논문집
    • /
    • 제9권6호
    • /
    • pp.5-12
    • /
    • 2008
  • 본 연구에서는 타이어셀로 보강된 모래지반에 대한 평판재하시험을 유한요소법에 의해 모델링하였다. 타이어셀의 기능과 외양은 지오셀과 비슷하며 지오셀과 마찬가지로 토목구조물에서 지반보강 목적으로 사용할 수 있다. 해석결과는 모델링의 적절성을 평가하기 위해 현장 재하시험결과와 비교하였다. 두 결과의 비교로부터 유한요소해석에 의한 침하량은 극한지지력에서 실험결과와 유사한 값을 나타내었다. 모델링을 검증한 후 타이어셀의 보강깊이와 보강층 수의 변화에 대한 해석을 수행하였다. 보강효과는 보강깊이가 증가함에 따라 감소하였으며 이러한 경향은 기존의 시험결과와 유사하였다. 보강층수가 증가함에 따라 보강효과는 증가하였다. 그러나 2층 이상의 보강은 효과가 무시할 정도였다. 결론적으로 본 연구에서의 모델링 방법은 타이어셀을 사용한 지반구조물의 해석에 사용할 수 있을 것으로 생각된다.

  • PDF

조사 대상 부지 신규 분류 체계 제안 및 개황조사 강화를 통한 토양정밀조사 방법 개선 연구 (Improvement of Detailed Soil Survey Guidance through the New Site Classification System and Reinforcement of Exploratory Soil Survey)

  • 권지철;이군택;황상일;김태승;윤정기;김지인
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권7호
    • /
    • pp.53-60
    • /
    • 2015
  • This study suggested the new site classification system according to land use, type of contamination and contaminants. Because the present site classification system can not cover all the areas, we changed the concept of land use to more detail one and enlarged the concept of other areas to cover all the areas not defined as certain land use. In case of the present industrial area, it was merged as other areas to avoid the confusion with oil and toxic material storage tank farm area. Accident area was separated from other areas and defined as only accident area caused by the mobile storage facility. In addition to classify the sites according to the basic land use, we classify the sites again in lower level according to the type of contamination and contaminants. With this classification system, we proposed different soil sampling strategy with the consideration of the origin of contamination and the interactions between soil and contaminants. We removed the surface soil sample (0~15 cm depth) around above storage tank because it was not a effective sample to assess whether that area contaminated or not. We also proposed to take the deeper soil samples at minimum three sampling points to confirm the depth of contamination in exploratory soil survey. We also proposed to remove the one point of 15 m depth sampling because it is not effective to confirm contaminated soil depth and needs the exhausted labor and cost. Instead of doing this, we added the continuous sampling to uncontaminated subsoil. Soil sampling points and depth in detailed soil survey is determined based on the results of exploratory soil survey. Therefore, effectiveness and reinforcements of exploratory soil survey would play an important role in improving the reliability of detailed soil survey.

옥상녹화에서 토심, 토양배합비 및 지피식물에 따른 식재지반 수분 및 온도변화 (Change of the Moisture and Temperature in Planting Ground as Effected by Different Soil Thickness, Soil Mixture Ratios and Ground Cover Plants in the Green Roof System)

  • 주진희;윤용한
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.11-16
    • /
    • 2010
  • This paper has attempted to investigate the change in soil moisture volume and temperature of architecture by planting ground(soil thickness and soil mixture ratio) and ground cover plants(Sedum sarmentosum, Zoysia japonica, Chrysanthemum zawadskii) for middle region green roof system. For this, a test was conducted on the roof of Konkuk University building from April 2009 to October 2009. In terms of treatment, five types(SL, $P_7P_1L_2$, $P_6P_2L_2$, $P_5P_3L_2$, $P_4P_4L_2$) depending on soil mixture ratio and two types(15cm, 25cm) by soil depth were created. Results of soil moisture volume by soil mixture ratio in the 15cm soil thickness showed that the difference was significance between simple soil and mixture soil treatment, however, the statistical significance was not recognized according to soil mixture ratio. In case of 25cm soil thickness, soil moisture volume by soil mixture ratio was more higher 7Vol.%~10Vol.% in the mixture soil than simple soil treatment. In terms of districts planted ground cover plants, soil volume moisture differed among plants in the order Zoysia japonica 17.74 Vol.%$34.86^{\circ}C$, district non-planted $27.49^{\circ}C$, Sedum sarmentosum $25.11^{\circ}C$, Chrysanthemum zawadskii $23.08^{\circ}C$, Zoysia japonica $24.45^{\circ}C$ respectively So, concrete surface showed more higher $5^{\circ}C{\sim}15^{\circ}C$ than other things among the all the time. Result of inner temperature of the architecture and soil, it was measured inner of architecture $25.69^{\circ}C$, inner district non-planted $24.29^{\circ}C$, Chrysanthemum zawadskii $23.90^{\circ}C$, Zoysia japonica $24.02^{\circ}C$, Sedum sarmentosum $25.13^{\circ}C$, respectively.

수평으로 경사진 박스암거 위 콘크리트 포장 슬래브의 최적 줄눈위치 (Optimal Joint Position in Concrete Pavement Slab over Skewed Box Culvert)

  • 염우성;정호성;연우;손덕수;이재훈;정진훈
    • 한국도로학회논문집
    • /
    • 제15권5호
    • /
    • pp.47-55
    • /
    • 2013
  • PURPOSES : The purpose of this study is to investigate the optimal joint positions which can minimize distresses of concrete pavement containing box culvert with horizontally skewed angles. METHODS : The concrete pavement containing the box culvert with different skewed angles and soil cover depths was modeled by 3 dimensional finite element method. The contact boundary condition was used between concrete and soil structures in addition to the nonlinear material property of soil in the finite element model. A dynamic analysis was performed by applying the self weight of pavement, negative temperature gradient of slab, and moving vehicle load simultaneously. RESULTS : In case of zero skewed angle ($0^{\circ}$), the maximum tensile stress of slab was the lowest when the joint was positioned directly over side of box culvert. In case there was a skewed angle, the maximum tensile stress of slab was the lowest when the joint passed the intersection between side of the box culvert and longitudinal centerline of slab. The magnitude of the maximum tensile stress converged to a constant value regardless the joint position from 3m of soil cover depth at all of the horizontally skewed angles. CONCLUSIONS : More reasonable and accurate design of the concrete pavement containing the box culvert can be possible based on the research results.

Stability of rectangular tunnel in improved soil surrounded by soft clay

  • Siddharth Pandey;Akanksha Tyagi
    • Geomechanics and Engineering
    • /
    • 제34권5호
    • /
    • pp.491-505
    • /
    • 2023
  • The practical usage of underground space and demand for vehicular tunnels necessitate the construction of non-circular wide rectangular tunnels. However, constructing large tunnels in soft clayey soil conditions with no ground improvement can lead to excessive ground deformations and collapse. In recent years, in situ ground improvement techniques such as jet grouting and deep cement mixing are often utilized to perform cement-stabilisation around the tunnel boundary to prevent large deformations and failure. This paper discusses the stability characteristics and failure behaviour of a wide rectangular tunnel in cement-treated soft clays. First, the plane strain finite element model is developed and validated with the results of centrifuge model tests available in the past literature. The critical tunnel support pressures computed from the numerical study are found to be in good agreement with those of centrifuge model tests. The influence of varying strength and thickness of improved soil surround, and cover depth are studied on the stability and failure modes of a rectangular tunnel. It is observed that the failure behaviour of the tunnel in improved soil surround depends on the ratio of the strength of improved soil surround to the strength of surrounding soil, i.e., qui/qus, rather than just qui. For low qui/qus ratios,the stability increases with the cover; however, for the high strength improved soil surrounds with qui >> qus, the stability decreases with the cover. The failure chart, modified stability equation, and stability chart are also proposed as preliminary design guidelines for constructing rectangular tunnels in the improved soil surrounded by soft clays.

강원도지역의 토양동결심 및 상록식물의 함수량 추이에 관한연구 (1) (Studies on the soil freezing depth and change of moisture contents in evergreen plants upon subzero temperature in)

  • 홍종운;허범양;원경열;임병춘;이기철;하상건
    • 아시안잔디학회지
    • /
    • 제4권1호
    • /
    • pp.42-48
    • /
    • 1990
  • Experiments were conducted to investigate the soil freezing depth and pattern with freezing measuring instruments during 1988-l989 winter season in Kangwon province. Freezing measuring instrument was made with acrylic pipes which were consisted of inner and outer parts. Inner pipe was filled with 0.01 % methylene blue solution and rubber hose to protect pipe breakdown by solution freezing. Freezing measurements were carried out by observing discoloration of methylene blue solution. Moisture content of evergreen trees and ground cover plants was also examined in the winter season. The observed results are as follows: 1.In the land of I OOM above sea level, soil freezing depth became deeper as the sum of Accumulated degree-days of temperature below 0˚C(0˚C . day) increased: Soil freezing depth was 30-40cm at l00˚C, 42-43cm at 150˚C, and 47cm at 200˚C day 2.Soil freezing with vinyl mulching was less developed by l3cm at l00˚C with sum of subzero temperature, by l7cm at 200˚C than that of the bare ground. Soil of rich hulls mulching with 4Ocm was not frozen until soil freezing at the bare ground was developed to 25cm depth. 3.Cashmeron mulching was more effective than felt mulching in the heat insulation of soil. 4.Thawing of soil was done from the lowest part of the frozen in the ground to upward in the beginning and after that it was done from the surface of frozen soil to downward. Finally thawing was completed at the middle of frozen soil.

  • PDF

Performance Test of a Real-Time Measurement System for Horizontal Soil Strength in the Field

  • Cho, Yongjin;Lee, DongHoon;Park, Wonyeop;Lee, Kyouseung
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.304-312
    • /
    • 2016
  • Purpose: Soil strength has been measured using a cone penetrometer, which is making it difficult to obtain the spatial data required for precision agriculture. Our objectives were to evaluate real-time horizontal soil strength (RHSS) to measure soil strength in real time while moving across the field. Using the RHSS data, the tillage depth was determined, and the power consumption of a tractor and rotavators were compared. Methods: The horizontal soil-strength index (HSSI) obtained by the RHSS was compared with the cone index (CI), which was measured using a cone penetrometer. Comparison analysis in accordance with the measurement depth that increased at 5-cm interval was conducted using kriged maps at six sensing depths. For tillage control and evaluation of the power consumption, the system was installed with a potentiometer for tillage depth, a torque sensor from the rear axle, and a power take-off (PTO) shaft. Results: The HSSI was lower than the CI, but they were the same at 54.81% of the total grids for the 5-cm depth and at 3.85% for the 10-cm depth. In accordance with the recommended tillage map, tillage operations between 0 and 15 cm left 2.3% and 7% residue cover on the soil, and that between 20 and 10 cm covered a wider utilization of 3% and 18.4%, respectively. When the tillage depth was 15 cm, the comparison result of the power requirements between the PTO and rear axle in terms of control performance revealed that the maximum power requirements of the axle and PTO were 44.63 and 23.24 kW, respectively. Conclusions: An HSSI measurement system was evaluated by comparison with the conventional soil strength measurement system (CI) and applied to a tractor to compare the tillage power consumption. Further study is needed on its application to various farm works using a tractor for precision agriculture.