• Title/Summary/Keyword: soil column

Search Result 836, Processing Time 0.033 seconds

A study on the fixation of heavy metals with modified soils in the landfill liner (개량혼합토를 이용한 폐기물 매립지 차수층의 중금속 고정능력에 관한 연구)

  • 노회정;이재영
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.63-71
    • /
    • 2002
  • The authors selected the modified soil method, and then performed the geotechnical and environmental laboratory test, and evaluated whether the modified soil liner could be accepted as a barrier layer in landfill. Unlike the results of the natural soil(CL), those of the hydraulic conductivity test of stabilized soil met the standard value. According to these results, the optimal mixing ratio of a mixture(cement : bentonite : stabilizing agent) was 90 : 60 : 1 with mass ratio(kg) for 1㎥ with soil, and it was possible to use poor quality bentonite. B\circled2 because of a little difference from results with high quality bentonite. B\circled1. The Cation Exchange Capacity(CEC) of the modified soil was increased about 1.5 times compared with the natural soil; however. the change of CEC with a sort of additives was not detected. In order to observe the change of the chemical components and crystal structures, the natural and the modified soils with the sorts of additives were measured by the XRF(X-Ray Flourescence Spectrometer) and SEM, but there was no significant change. The artificial leachate with the heavy meals ($Pb^{2+}$ , $Cu^{2+}$, $Cd^{2+}$ Zn$^{2+}$ 100mg/L) was passed through the natural soil and modified soils in columns. In the natural soil, Cd$^{2+}$ and $Zn^{2+}$ were identified, simultaneously the pH of outflow was lower, and then came to the breakthrough point. The removal efficiency of the natural soil was showed in order of following : $Pb^{2+}$$Cu^{2+}$ > $Zn^{2+}$ > $Cd^{2+}$ On the other hand, modified soils were not showed the breakthrough condition like the result of the natural soil. The modified soil with the lower quality bentonite, B\circled2(column3) was more stable with respect to chemical attack than that with the higher bentonite, B\circled1(column2) because the change range of outflow pH in columns was less than that of outflow pH in column2. In addition, the case of adding the stabilizing agent(column4) was markedly showed the phenomena.ena.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

Removal of Cesium and Cobalt within Soil around TRIGA Reactor by Electrokinetic method (동전기적방법을 이용한 TRIGA 연구로 주변 토양내의 세습과 코발트 제거)

  • 김계남;원희준;정종헌;오원진
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.13-23
    • /
    • 2004
  • The characteristics of cesium and cobalt removal from soil around the TRIGA reactor using the electrokinetic method were analyzed and a device to restrain the pH increase in the soil column was suggested. When a NaCl solution was used as the electrolyte to raise the electric field strength, a precipitate was formed in the cathode in the soil column, resulting in a low removal efficiency. Thus, an acetate buffer solution (compound solution of $CH_3COONa$ and $CH_3COOH$) was injected into the soil column and acetic acid was periodically infected into the cathode reservoir to restrain any pH increase. Many $Cs^{2+}$ and $Co^{2+}$ ions were transferred by electromigration rather than electroosmosis during the initial remediation period, and no precipitate was formed in the soil column. 96% of the total amount of cesium in the soil column was removed after 5.9 days, while 94% of the total amount of cobalt was removed. Furthermore, the residual concentrations predicted by the developed model were similar to those obtained by experiment.

  • PDF

The Purification Characteristics of the Reactive Soil-Bentonite Landfill Liner (혼합반응차수재의 오염정화특성 연구)

  • 장경준;황의석;안기봉;김학문
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.585-592
    • /
    • 2003
  • The purpose of this paper is to investigate purification characteristic of soil-bentonite landfill liner and to develop of desirable liner system. In this study, column tests for soil-bentonite, reactive soil-bentonite and existing bentomat and reactive bentomat were carried out under the high pressure with water and leachate.

  • PDF

Behavior of Synthetic Pyrethroid Insecticide Bifenthrin in Soil Environment II) Identification of Degradation Product and Leaching of Bifenthrin in soil (합성 Pyrethroid 계 살충제인 Bifenthrin의 토양환경중 동태 제2보. Bifenthrin의 토양중 분해산물의 동정 및 용탈)

  • Kim, Jang-Eok;Choi, Tae-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.2
    • /
    • pp.125-132
    • /
    • 1992
  • This study was conducted to know degradation products of the synthetic pyrethroid insecticide bifenthrin under soil, aqueous solution and UV-light irradation, and know its movement by leaching in soil. The major degradation product of bifenthrin was identified with 2-methylbiphenyl -3-y1 methanol by HPLC, UV, Mass and NMR under soil, aqueous solution and UV-light irradiation, The main degradation route was hydrolysis of the ester linkage. On exposure to UV-light, bifenthrin was decomposed almost completely in concentrations of 10 and 100 ppm in 24 hr but decomposed about 80% in 1,000 ppm. Bifenthrin was immobile in soil column system and on soil thin-layer chromatography system. Mostly bifenthrin remained in the 0-2.0㎝ layer of soil column and soil TLC.

  • PDF

Influence of column yielding on degree of consolidation of soft foundations improved by deep mixed columns

  • Jiang, Yan;Han, Jie;Zheng, Gang
    • Geomechanics and Engineering
    • /
    • v.6 no.2
    • /
    • pp.173-194
    • /
    • 2014
  • Laboratory and field data showed that deep mixed (DM) columns accelerated the rate of consolidation of the soft foundations. Most analyses of consolidation of DM column-improved foundations so far have been based on the elastic theory. In reality, the DM columns may yield due to the stress concentration from the soft soil and its limited strength. The influence of column yielding on the degree of consolidation of the soft foundation improved by DM columns has not been well investigated. A three-dimensional mechanically and hydraulically-coupled numerical method was adopted in this study to investigate the degree of consolidation of the DM column foundation considering column yielding. A unit cell model was used, in which the soil was modeled as a linearly elastic material. For a comparison purpose, the DM column was modeled as an elastic or elastic-plastic material. This study examined the aspects of stress transfer, settlement, and degree of consolidation of the foundations without or with the consideration of the yielding of the DM column. A parametric study was conducted to investigate the influence of the column yielding on the stress concentration ratio, settlement, and average degree of consolidation of the DM column foundation. The stress concentration ratio increased and then decreased to reach a constant value with the increase of the column modulus and time. A simplified method was proposed to calculate the maximum stress concentration ratios under undrained and drained conditions considering the column yielding. The simplified method based on a composite foundation concept could conservatively estimate the consolidation settlement. An increase of the column modulus, area replacement ratio, and/or column permeability increased the rate of consolidation.

The study on the Characteristics of Ultimate Bearing Capacity and Major Design Parameters for Single Stone Column (단일 쇄석다짐말뚝의 지지력 특성과 주요 설계 파라미터에 관한 고찰)

  • Chun, Byung-Sik;Kim, Won-Cheul;Jo, Yang-Woon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.552-560
    • /
    • 2004
  • Stone column is a soil improvement method and can be applicable for loose sand or weak cohesive soil. Since the lack of sand in Korea, stone column seems one of the most adaptable approach for poor ground as a soil improvement method. However, this method was not studied for practical application. In this paper, the most effective design parameters for the being capacity of stone column were studied. The parametric study of major design factors for single stone column was carried out under the bulging and general shear failure condition, respectively. Especially, a test result of single stone column by static load was compared with the bearing capacity values of suggested formulas. The analysis result showed that the ultimate bearing capacity by the formula was much less than the measured value by the static load test. Especially, the result of the parametric study under general shear failure condition showed that the bearing capacity has apparent difference between each suggested formulas with the variation of the major design parameters. Therefore, the result of this study can be a suggestion which is applicable for the field test and the future research.

  • PDF

The Characteristics of Bioremediation for VOCs in Soil Column (VOCs 처리를 위한 미생물의 토양복원화 특성)

  • 손종렬;장명배;조광명
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.1
    • /
    • pp.52-56
    • /
    • 2002
  • The study was carried out to evaluate the characteristics of biodegradation by Pseudomonas putida G7 in soil column. The reactor system was used to investigate mass transfer of VOCs as Toluene in a column of unsaturated soil. Determination of the fate of VOCs in unsaturated soil is necessary to evaluate the feasibility of natural attenuation as a VOCs remediation strategy. The objective of this study was to develop a mechanistically based mathematical model that would consider the interdependence of VOC transport, microbial activity, and sorptive interactions in a moist, unsaturated soil. Because the focus of the model was on description of natural attenuation, the advective VOCs transport that is induced in engineered remediation processes such as vapor extraction was not considered. It can be concluded that the coefficient for gas liquid mass-transfer was found to be a key parameter controlling the ability of bacteria to VOCs. Finally, it appeared that bioremediation technology of VOCs which are difficult to be decomposed by chemical methods.

Characteristics of Settling and Consolidation Behavior for Non-Plastic Dredged Soils (비소성 준설토의 침강-압밀 거동 특성)

  • Park, Yun-Gyun;Park, Byung-Soo;Jeong, Gil-Soo;Yoo, Nam-Jea
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.251-261
    • /
    • 2004
  • A series of column test with a silty marine soil mixed with Jumunjin Standard Sand were performed to investigate the characteristics of settling and consolidation of non-plastic dredged soils. Column tests were carried out by using the separable column to measure the grain size distribution of consolidated layer. Column tests were performed with changing the mixing ratio of Jumunjin Standard Sand to the silty marine soil, initial water content of slurry and initial height of slurry. Height of interface of slurry was monitored during tests and grain size distribution tests were carried out after finishing tests. Influencing factors on the particle segregation, eventually to the characteristics of settling and consolidation of non-plastic soil, were analyzed on the thesis of test results. As results of column tests, the mixing ratio of sand to the silty marine soil and the initial water content of slurry were known to affect the characteristics of settling and consolidation resulted in significant particle segregation of slurry. Initial height of slurry was found not to affect seriously to particle segregation.

  • PDF

Bearing capacity of footing supported by geogrid encased stone columns on soft soil

  • Demir, Ahmet;Sarici, Talha
    • Geomechanics and Engineering
    • /
    • v.12 no.3
    • /
    • pp.417-439
    • /
    • 2017
  • The stone columns are increasingly being used as a soil improvement method for supporting a wide variety of structures (such as road embankment, buildings, storage tanks etc.) especially built on soft soil. Soil improvement by the stone column method overcomes the settlement problem and low stability. Nevertheless, stone column in very soft soils may not be functional due to insufficient lateral confinement. The required lateral confinement can be overcome by encasing the stone column with a suitable geosynthetic. Encasement of stone columns with geogrid is one of the ideal forms of improving the performance of stone columns. This paper presents the results of a series of experimental tests and numerical analysis to investigate the behavior of stone columns with and without geogrid encasement in soft clay deposits. A total of six small scale laboratory tests were carried out using circular footing with diameters of 0.05 m and 0.1 m. In addition, a well-known available software program called PLAXIS was used to numerical analysis, which was validated by the experimental tests. After good validation, detailed of parametric studies were performed. Different parameters such as bearing capacity of stone columns with and without geogrid encasement, stiffness of geogrid encasement, depth of encasement from ground level, diameter of stone columns, internal friction angle of crushed stone and lateral bulging of stone columns were analyzed. As a result of this study, stone column method can be used in the improvement of soft ground and clear development in the bearing capacity of the stone column occurs due to geogrid encasement. Moreover, the bearing capacity is effected from the diameter of the stone column, the angle of internal friction, rigidity of the encasement, and depth of encasement. Lateral bulging is minimized by geogrid encasement and effected from geogrid rigidity, depth of encasement and diameter of the stone column.