• Title/Summary/Keyword: soft contact Lens

Search Result 120, Processing Time 0.025 seconds

Effects of natural and chemical disinfectants on soft contact lens infected with Pseudomonas aeruginosa : Scanning Electron Microscopic study (Soft contact lens에 있어서 천연보존제와 합성보존제의 살균효과 : 주사 전자현미경적 관찰)

  • Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.65-69
    • /
    • 2003
  • The effects of grapefruit seed extract and $H_2O_2$ disinfectants on Pseudomonas aeruginosa were investigated by antimicrobial assay and scanning electron microscopy. Pseudomonas aeruginosa is a Gram negative bacteria and a common causative microorganism of bacterial keratitis. After incubation of soft contact lens in Pseudomonas aeruginosa suspension for 120 minutes containing the disinfectants, the grapefruit seed extract showed antimicrobial activity as good as the chemical disinfectant. The living rates of Pseudomonas aeruginosa in grapefruit seed extract and $H_2O_2$ disinfectants were $1{\times10^3CFU/m{\ell}$ and $0.5{\times}10^3CFU/m{\ell}$, respectively showing no major difference in the killing activity. However, the mechanisms of the antimicrobial activity were quite different as indicated by scanning electron microscopy of the bacterial surface morphology. Considering chemically or other toxins induced keratitis, the natural disinfectant isolated from grapefruit seed extract shows promising results as a soft contact lens disinfectant.

  • PDF

Evaluation of Transmittance Characteristics of Contact Lenses (콘택트렌즈의 광투과율 특성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Kim, Do-Hyung;Paik, Sun-Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.37-45
    • /
    • 2007
  • We have measured the spectral transmittances of UV blocking soft contact lenses, regular soft contact lenses and regular RGP lenses using the method suggested in ANSI Z80.20 standard. In order to evaluate visible light transmitting and UV blocking characteristics, we have calculated transmittances by integrating over the specific spectral ranges, i.e., visible light, UVA, UVB and UVC. We found that mean transmittances of visible light for all three categories were over 90.0 % which could be considered as within acceptable range for a contact lens. The transmittance of the UVA and UVB radiation for the UV blocking soft lenses except some cases was within UVR (Ultraviolet radiation) transmittance standard. The UV blocking ability of regular soft and RGP lenses was poor as rather expected. These results will be expected to assist clinical opticians and practitioners in utilizing the transmittance characteristics about the contact lens.

  • PDF

Relationship between the Deposition of Tear Constituents and the Adherence of Candida albicans according to Soft Contact Lens Materials and Pigmentation (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 칸디다균 흡착의 상관관계)

  • Park, So Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.215-225
    • /
    • 2016
  • Purpose: The aim of this study was to figure out how the characteristics of soft contact lens materials and pigmentation affect the adherence of C. albicans on soft contact lenses pre-deposited with tear constituents. Methods: The adherent number of C. albicans on clear soft contact lenses (hereinafter clear lenses) and circle soft contact lenses (hereinafter circle lenses) made of etafilcon A, hilaiflcon B and nelfilcon A, respectively, was measured before and after the deposition of artificial tear. Also, bacteria adherence on lenses were observed by a scanning electron microscope. Results: Adherence of C. albicans was significantly different according to lens materials. The amount of adsorption was not different between clear lenses and circle lenses made of etafilcon A however, the number of bacteria absorption was bigger in hilafilcon B and nelfilcon A lenses. More absorption of C. albicans was found in the non-pigmented central area compared the pigmented area, and non-pigmented peripheral area has more bacterial absorption than non-pigmented central area. The number of C. albicans decreased in the case that tear protein was pre-deposited. The maintenance of antibacterial activity against C. albicans was different according to lens materials thus, etafilcon A has the longest period of its maintenance. Conclusions: It was revealed that the number of C. albicans was different according to the characteristics of lens materials, pigmentation or non-pigmentation, the pigmented area of soft contact lenses. Thus, it is suggested that the management method should be different according to the adsorption characteristics of C. albicans.

Effects of UV-A Blocking Contact Lenses on the Enzymes Denaturation Induced by UV-A Irradiation (UV-A로 유발된 효소 변성에 대한 콘택트렌즈의 차단 효과)

  • Park, Mijung;Lee, Keum Hee;Lee, Eun Kyung;Park, Sang Hee;Kim, So Ra;Lee, Heum Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.43-49
    • /
    • 2008
  • Purpose: The current study was conducted to evaluate the compatibility of UV-A blocking contact lens on eye protection with regular contact lens. Methods: The protective activity of regular contact lens (UV-A blocking: 20%) and UV-A blocking contact lens (UV-A blocking: 85%) on the denaturation of RNase A, catalase, and superoxide dismutase (SOD) induced UV-A irradiation were compared by acrylamide gel electrophoresis. The enzyme solutions were irradiated with UV-A for 1, 3, 6, 24 and 96 hours at the wavelength of 365 nm. Covering area with contact lenses were varied as 50%, 70% and 100% according to the calculation of blocking areas of anterior eye that could be covered with RGP lens, soft contact lens, and eye glasses, respectively. Results: Denaturations of RNase, catalase and SOD were exaggerated when they were exposed to UV-A for a longer period. The denaturation was effectively prevented by UV-A blocking contact lens compared to regular contact lens. The capability of UV-A blocking contact lens was considerably reduced when the covering area with contact lens decreased and exposure time to UV-A extended. Conclusion: Therefore, it would be suggested that wearing contact lens for a long time under sunlight is carefully considered since the activity of UV-A blocking contact lens against UV-A irradiation may not be enough to protect enzymes presented in eyes when exposure time to UV-A increased.

  • PDF

Central Corneal Thickness of Normal Eyes and Contact Lens-wearing Eyes Aged in their 20s and 30s (20․30대 정상안과 콘택트렌즈 착용안의 각막 중심 두께)

  • Park, Mijung;Park, Kyeong Sun;Ahn, So Yeoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.29-35
    • /
    • 2007
  • This study was conducted to measure the central corneal thickness(CTT) changes associated with kinds of wearing contact lens. The CCT was measured using ultrasonic pachymeter in three hundred four subjects in their 20s and 30s. Although the CCT of Group 1 who had never worn any kinds of contact lens had no differences between left and right eye as well as between genders, the CCT tended to become thinner depending on the increment in refractive error. In Group 2 wearing only soft contact lens, the CCT was thinner depending on wearing period, and subjects wearing for more than 10 years had significantly thin CCT comparing with subjects wearing for less than 4 years. There was no significant difference in the CCT between Group 3 wearing only RGP lens and Group 2 for less than 4 years. Furthermore, when comparing the CCT between the Group 2 and Group 4 changing to RGP lens after wearing soft contact lens, there was no statistically significant change in the CCT. However, the CCT was significantly thinner in Group 5 changing to soft contact lens after wearing PMMA(polymethyl methacrylate) hard lens compared with Group 2.

  • PDF

Microbial Contamination of Contact lens cases in multi - purpose solution care systems (다목적 용액을 사용하는 콘택트렌즈 관리체계에서 렌즈 보관용기의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2000
  • The microbial contamination rate of contact lens cases in multi-purpose solution(MPS) care systems of 80 asymptomatic soft contact lens wearers was investigated. In caring for their lenses 72 patients (90%) used chemical disinfection(include MPS), six patients(7%) used hydrogen peroxide, and two patients(3%) used heat. Fifty-nine percent of patients used MPS in their care systems. Of 80 contact lens cases, contamination was found in 68%(54) of cases. There is a significant relationship between the ages of lens cases and contamination: older cases being more frequently contaminated. Of the contaminated 31 lens cases(57%) in MPS care systems, four contact lens cases(13%) were contaminated by single organism, 15 cases(48%) by two kinds of organisms, and 12 cases(39%) by more than three kinds of organisms. Of the organisms that were contaminated lens cases, Pseudomonas. Serratia, Bacillus, E. coli and Aspergillus were frequently isolated. When considering the high contamination rate of soft contact lens cases in MPS care systems more effective and hygienical lens care system is important, especially frequent and regular disposal of lens cases may prove to prevent the build-up of microbial colonisation in containers.

  • PDF

Microbial contamination in contact lens care systems (Contact lens care system의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The microbial contamination in contact lens care systems and conjunctivas of 40 asymptomatic cosmetic soft contact lens wearers was investigated. Patient ages ranged from 19 to 27(mean:22), most of them have used hydrogel contact lenses for less than 1 year, and the ages of lens cases were 1 weeks ~ 3 months (43 %) or 4~6 months (52%). Twenty-seven patients (67%) chemically disinfected their lenses and 8(20 %) used hydrogen peroxide, and 5 used heat to disinfect. Fourteen patients used commercial non-preserved saline, and 26(65%) were using commercial preserved saline. Sixty-two percent of the patients had bacterial contamination of lens case, and 17% had conjunctival contamination. The bacterial contamination rate was highest in lens cases, followed by unpreserved salines, disinfecting chemicals(non-hydrogen peroxide), and conjunctivas. The fungal contamination rate of cases and conjunctivas was 67% and 15%, respectively, and lens case, unpreserved saline, and conjunctiva seemed more susceptible to contamination. The use of hydrogen peroxide for disinfection rather than chemical disinfection was associated remarkabley with decreased contamination of solution itself, and there was no significant difference in contamination rates between hydrogen peroxide care system and other disinfecting systems. Five of lens cases(13%) and 2 conjunctivas(5%) were contaminated with Pseudomonas aeruginosa, and Candida albicans were isolated from 11cases (27%) and 5 conjunctivas (12%). Of the organisms that were contaminated lens cases and conjunctivas, Pseudomonas aeruginosa, Escherichia coli, Candida albicans, and Aspergillus fumigatus were isolated from lens cases, whereas Pseudomonas aeruginosa, Candida albicans, and Aspergillus fumigatus were recorvered from conjunctivas. Fortunately all of the these tested samples showed 0% of Acanthamoeba in this investigation.

  • PDF

Application of superficial keratectomy and soft contact lens for the treatment of symblepharon in a cat: a case report

  • Kim, Youngsam;Kang, Seonmi;Seo, Kangmoon
    • Journal of Veterinary Science
    • /
    • v.22 no.2
    • /
    • pp.19.1-19.5
    • /
    • 2021
  • A 7-month-old intact female Persian cat was diagnosed with symblepharon accompanied by epiphora, brownish ocular discharge, and ocular discomfort in the left eye. Superficial keratectomy (SK) was performed to remove adhesions between the conjunctiva and cornea. To prevent re-adhesion after SK, the detached conjunctival tissue was sutured to the corneal limbus, and a soft contact lens (SCL) was inserted and a partial temporary tarsorrhaphy was performed. The SCL and tarsorrhaphy sutures were maintained for 22 days, and symblepharon did not recur 347 days postoperatively. SK combined with SCL is a relatively easy and cost-effective surgical option for feline symblepharon.

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

A Study of Ultrastructure on attachment of Soft Contact Lens Surface of Incubated Pseudomonas aeruginosa (배양된 Pseudomonas aeruginosa의 소프트 콘택트 렌즈 표면부착에 대한 미세구조적 연구)

  • Kim, Douk Hoon;Park, Yong Tae;You, Hae Byung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.

  • PDF