• Title/Summary/Keyword: soft contact Lens

Search Result 120, Processing Time 0.023 seconds

Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness (두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2157-2163
    • /
    • 2009
  • The oxygen permeability of a soft contact lens is an important parameter for determining corneal health when considering the physiological response of the eye. The aim of this study is to evaluate the oxygen permeability of soft contact lenses based on thickness, using the polarographic method. The thickness of lens was measured using contact and non-contact method. To assess accuracy and reliability, the Bland-Altman plot was used. The reliability was high for the oxygen permeability based on center thickness measured by contact method, whereas the accuracy was high for the oxygen permeability based on center thickness measured by non-contact method. These results indicate that the permeability characteristics were variable according to the measurement and criteria of thickness of soft contact lenses and the measurement of soft contact lenses by non-contact method was more reasonable. Thus, contact lens practitioners should consider some basic differences between methodologies when interpreting or quoting oxygen performance data.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Relationship between the Deposition of Tear Constituents on Soft Contact Lenses according to Material and Pigmentation and Adherence of Staphylococcus aureus (소프트콘택트렌즈 재질과 착색에 따른 눈물성분 침착과 포도상구균 흡착의 상관관계)

  • Park, So Hyun;Park, Ill-suk;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.109-117
    • /
    • 2016
  • Purpose: The study was aimed to figure out the effect of materials and pigmentation of soft contact lens on the adherence of Staphylococcus aureus upon soft contact lenses deposited with tear components. Methods: The number of adherent S. aureus on clear and circle soft contact lenses made of etafilcon A, hilafilcon B, nelfilcon A was measured before and after incubation in artificial tear. Furthermore, the denaturalization level of tear protein with time after incubation in artificial tear was estimated by electrophoresis. Results: The adherence of S. aureus was significantly different according to the lens materials. The pattern of bacterial adherence on clear and circle contact lenses was different. That is, the adherent amount of S. aureus was somewhat larger on circle lens made of etafilcon A however, amount on circle lenses made of hilafilcon B and nelfilcon A was 89.3% and 71.3% of the number on clear lenses. When the tear protein was deposited on contact lenses, the number of adherent bacteria decreased and its degree was varied according to the lens material. The degree of decrease was the biggest in clear soft lens made of etafilcon A. Anti-bacterial effect of tear protein decreased with time after deposition of tear protein on soft contact lens and the amount of lysozyme also decreased. The reduction of anti-bacterial effect and quantity of lysozyme was different according to contact lens materials and pigmentation. Conclusions: It was revealed that the adherence of S. aureus depends on contact lens materials and pigmentation, and the specification of lens material affects more on adherence of S.aureus than pigmentation. It was further figured out the denaturalization level of anti-bacterial protein on soft contact lens varies according to lens materials and pigmentation, which produces an effect on the quantity of bacterial adherence.

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

A Survey about Wearing Soft Contact Lenses for Astigmatism Correction of The Local College Students, Gyeongsangnam-Do, Korea (경남지역 대학생들의 난시 교정용 소프트 콘택트렌즈의 착용에 관한 설문조사)

  • Kim, Bong-Hwan;Han, Seon-Hee;Kim, Dae-Hyeon;Byeon, Sang-Hyeon;Chae, Jeong-Im;Kim, Jae-Seok;Hwang, Yun-Jeong;Kim, Hak-Jun
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.3
    • /
    • pp.378-389
    • /
    • 2015
  • Purpose. The actual status of wearing toric soft contact lenses was investigated to learn why it is not used although it is required. Materials and Methods. This study has studied 64 contact lens wearing the local college students, Gyeongsangnam-do who are 20.17(${\pm}0.70$)years old, by measuring their refractive power and over-refractive power with auto refractometer(HRK-8000A, Huvitz, Korea). In addition to that, a survey was done to figure out why they do not wear toric soft contact lenses, the purpose of using toric soft contact lenses, whether they have astigmatism or any knowledge about it, the kinds of contact lens, whether they are willing to buy corrective lenses, and how they are satisfied after purchasing them. Results. 17 students (21.9%) said they experienced light-spread; 9 students (14.1%)said that they have dizziness when they wear contact lens all day long. In the survey to see whether they had astigmatism or not, 37 students (57.8%) said they had it. For the reason they do not wear toric soft contact lenses, 33 students (51.6%) said that "they were prescribed regardless of astigmatism in the optometrist." To the question asking if they are willing to buy toric soft contact lenses according to the existence of astigmatism, 51 students (79.6%) answered they are. 31 students (48.4%) said they heard a description about astigmatism at the time of purchase for contact lens. Conclusion. As the ways for any people who need to correct astigmatism to wear corrective lens, enough education about astigmatism and consistent follow-up management are needed, where the role of optometrist is considered important.

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

A Study of antibacterial effect on pseudomonas aeruginosa of soft contact lens multi-purpose solution (MPS) (Pseudomonas aeruginosa에 대한 soft contact lens 다목적 용액의 항균효과)

  • Yoon, Min-Hwa;Park, Hyun-Ju;Lee, Ki-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.353-359
    • /
    • 2004
  • This study was performed to examine the pseudomonas aeruginosa, antibacterial effect of a soft contact lens multi-purpose solution (MPS). Pseudomonas aeruginosa was incubated in the Muller Hinton Broth culture, and treated with 5 MPSs. TO investigate the antibacterial efficiency of MPSs, UV spectrometer was used for measuring optical density of pseudomonas aeruginosa. The antibacterial effect of 4 MPSs was significant except for one MPS. This result suggested that the antibacterial effect of MPSs is dependant on their components, pH. Therefore they had antibacterial effect of the pseudomonas aeruginosa.

  • PDF

Study on protein adsorption resistant soft contact lens (단백질흡착을 막는 소프트콘택트렌즈에 관한 연구)

  • Jeong, Young-Il;Cho, Chong-Su;Na, Jae-Woon;Kim, Sung-Ho
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.223-225
    • /
    • 1996
  • Poly (ethylene glycol) (PEG)macromers terminated with acrylate groups and interpenetrating polymer networks(IPN) composed of poly(hydroxyethyl methacrylate)(PHEMA) or poly(hydroxyethyl methacrylate-co-hydropropyl methacrylate-co-N-vinyl pyrrolidone) [P(HEMA-co-HPMA-co-NVP)] and PEG macromer were synthesized with the aim of obtaining protein adsorption resisatnt soft contact lens. Polymerization of PEG macromer resulted in the formation of cross-linked gels due to the multifunctionality of macromer. Crosslinked P(HEMA) or P(HEMA-co-HPMA-co-NVP) chains were interpenetrated into the cross-linked three-dimensional networks of PEG. It was found that albumin adsorption onto the contact lens prepared by P(HWMA)/PEG IPN decreases with a decrease of molecular weight of PEG whereas its adsorption onto the contact lens prepared by P(HEMA-co-HPMA-co-NVP)/PEG IPN decreases with an increase of molecular weight of PEG. Also, it was found that albumin adsorption onto the both contact lens decreases with an increase of concentration of PEG macromer in the IPN preparation. There are also more adequate in the bioinertness and bioadhesion for the contact lens by P(HEMA)/PEG IPN or P(HEMA-co-HPMA-co-NVP)/PEG IPN than that by P(HEMA) or P(HEMA-co-HPMA-co-NVP).

  • PDF