• Title/Summary/Keyword: soft X-ray

Search Result 407, Processing Time 0.031 seconds

RESULTS FROM THE YOHKOH SATELLITE

  • WATANABE TETSUYA
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.291-294
    • /
    • 1996
  • The .Japanese sun observing satellite, Yohkoh, has been operational for five years and her scientific instruments are still in good condition. They have revealed ample of evidences that solar flares were triggered by magnetic reconnection, which was, for the first time, clearly indicated to take place in the solar corona. Cusp structures in soft X-rays and a new type of hard X-ray sources at the top of flaring loops have strongly supported the scenario originally proposed by C-S-H-KP. Nonthermal energy input in hard X-rays and thermal energy estimated from soft X-rays are fundamentally consistent with the interpretation of thick-target and chromospheric-evaporation models (Neupert effect). X-ray jets, another discovery of Yohkoh, were also associated with magnetic reconnection, as a result of the interaction of emerging fluxes with pre-existing coronal loops. Temperature structures of active regions, quiet sun, and coronal holes had very dynamic differential-emission-measure (DEM) distributions and high-temperature tails of DEM were considered to come from the contribution of flare-like activity.

  • PDF

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

4th Generation Light Source: X-ray Free Electron Laser (4세대 방사광: 엑스선 자유전자레이저)

  • Han, Jang-Hui
    • Vacuum Magazine
    • /
    • v.3 no.4
    • /
    • pp.4-7
    • /
    • 2016
  • An X-ray Free Electron laser facility (PAL-XFEL) has been built in Pohang Accelerator Laboratory to provide X-ray FEL radiations for photon users. The machine consists of a 10 GeV normalconducting S-band linear accelerator and two undulator beamlines. The hard and soft X-ray beamlines will provide FEL radiations with wavelengths of 0.6 to 0.1 nm and 4.5 to 1 nm, respectively. Beam commissioning of PAL-XFEL is ongoing and user service will start in 2017. In this report, the PAL-XFEL layout and the working principle are discussed.

Absorption Spectroscopy of Biological Specimens Near X-ray Absorption Edges of Constituent Elements

  • Ito, Atsushi;Shinohara, Kunio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.460-462
    • /
    • 2002
  • Absorption spectra of biological specimens in the soft X-ray region have been presented with special reference to the XANES (X-ray absorption Near Edge Structure) of constituent elements. Absorption spectrum in this wavelength region is characterized by the absorption edges from which elemental content could be derived. In addition, XANES has a characteristic profile for chemical environment around the element such as chemical bond. Using the specific absorption peak we can assign not only the chemical bond but also molecules having such a chemical bond. In the present paper, absorption spectrum of DNA was measured in the wavelength range from 1.5nm to 5nm. Spectrum of Chinese Hamster Ovary (CHO) cells was compared with the DNA spectrum. XANES were distinct at the K absorption edges of major elements, C, N and O. In the spectrum of the cells prominent peaks at the L absorption edge of minor element Ca were also detectable. XANES profiles in small local areas in a cell could also be measured in combination with X-ray microscopy. These give information about local chemical environment in a cell. XANES at the phosphorus K absorption edge in a human HeLa cell was successfully obtained corresponding to a sharp and intensive XANES peak of DNA.

  • PDF

Final Diffraction Patterns of the Beam Splitters used in the Soft XRay Interferometer by a He-Ne Laser

  • Oh, Chul-Han;Choi, Dae-Uk;Park, Sung-Jin;Howells, M.R.;Moller, E.J.
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.7-10
    • /
    • 2000
  • The soft x-ray(10nm-100nm) interferometer is a modified Mach-Zehnder type interferometer and it consists of two beam-splitters and four totally reflecting mirrors. The beam-splitters used here are 50% transmission and 50% reflection grating type. The diffraction patterns of beam splitters(1st B.S.) were investigated with a He-Ne laser. The diffraction patterns produced by the soft x-ray interferometer (2nd B.S.) were also investigated in intensities positions. The diffraction patterns of 20 degree grazing incidence on the beam splitters(1st B.S.) show a circular array of spots. Both the reflected and the transmitted beams show the same patterns but symmetric circles on the screen. The maximum intensity appears roughly when n is in the zeroth and odd orders and the suppressed peak(missing order) appears when n is in even orders. Intensities of 3 center fringes(n = 0, $\pm$1) are stronger than others. These results confirm the reduced grating equation and make agree with the intensity distribution function. It was found that the final patterns produced by the soft x-ray interferometer (2nd B.S.) consisted of fine fringes which were caused by two of three diffraction beams that were arrived at the second beam-splitter.

Soft X-ray emission from Ar clusters irradiated by an intense femtosecond laser (강한 펨토초 레이저에 의해 아르곤 송이에서 발생한 연엑스선)

  • ;T. Mocek
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.22-23
    • /
    • 2000
  • 강한 레이저 펄스에 의해 만들어진 플라즈마를 사용하여 연엑스선(soft X-ray, 10-300 $\AA$) 광원을 얻으려는 노력은 주로 고체나 기체 표적에 대한 것이었다. 최근에 이르러 기체의 단열 팽창에서 생기는 원자 송이(atomic cluster)를 표적으로 하는 연구 결과들이 발표되었다. $^{(1).(2)}$ 원자 송이는 국소적으로는 고체에 가까운 밀도를 가지고 있어서 효율적으로 레이저 에너지를 흡수하는 반면, 전체적으로는 기체 상태에 있기 때문에 파편이 적고, 기체의 압력과 온도를 변화시킴으로써 송이의 크기를 조절할 수 있다. (중략)

  • PDF

X-ray laser development using laser-produced plasmas (레이저-플라즈마를 이용한 X-선 레이저의 연구)

  • 남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.67-72
    • /
    • 1992
  • Since the inception of the idea to develop an X-ray laser in 1960's, a rapid progress to demonstrate soft X-ray lasers in the wavelength region below 300$\AA$ has been made during the last ten years. Among many prospective proposals, the recombination scheme and the collisional exitation scheme have been most successful in achieving a significant gain. An appreciable single-pass amplification was achieved at 182 $\AA$ from CVI ions using the recombination scheme and at 206 and 290$\AA$ from the Se XXV ions using the collisional excitation scheme. The current research on X-ray lasers emphasizes the enhancement of amplification upto saturation and the extension of operating wavelength to shorter wavelengths, especially to the water window region between 23 and 44 $\AA$. X-ray lasers are expected to open many application fields, such as X-ray laser microscopy, X-ray holography, X-ray lithography, and more, in the near future.

  • PDF

Diagnosis of Seed Quality for Korean White Pine by Soft X-Ray Photographs (연(軟) X-선(線) 사진(寫眞)에 의(依)한 잣나무 종자(種子)의 품질진단(品質診斷))

  • Min, Kyung Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 1974
  • The seed quality testing for Korean white pine (Pinus koraiensis), their pre-germination and embryo growing process were investigated and the abnormal embryo groups were discriminated by the use of soft X-ray photograph. The study results were as follows ; 1. The embryo reflection was clearly observed for air dried seeds (moisture content was 6.3%) at 30 sec, stratificated seeds at 60 sec (moisture content 24.0-36.0%) and immature seed (moisture content 41.0-64.0%) at 90sec., then the photographing variation for soft X-ray was the radiographing distance at 42cm focus M, voltage 19.5 K.V.P. and Ampere 8 mA. By the above result, the radiographing time for discriminating the embryo reflection was increased by the increase of moisture content in the seeds. 2. The embryo reflection could be clearly observed from the last ten days of June and the embryo length ratio to endosperm length was growing to 65% at the first ten days of September. By the result obtained the soft X-ray photograph was thought to be effective method for the study of inner morphology of seeds. 3. The clear reflection seeds for embryo and endorsperm were observed to 69.7% and the seeds were practically germinated to 75.2% The difference in number between the discriminated seeds by the soft X-ray photograph and the practically germinated seeds was only 6%. According to this results, the soft X-ray photograph was thought to be a effective methods for the germination diagnosis in the shortest time and with the exactness comparatively. 4. Because of the possibility of clearness for observation of pre-germination process, the soft X-ray photograph could be used for the study on the physiology of seed germination. 5. The frequency of abnormal embryos was observed of total 4.4% and their types and subtypes could be classified into twenty groups. Among these groups, single abnormal embryo type was divided into eight subtypes and observed of 2.0 percent, twin embryo was six subtypes and 1.8 percent, triple embryo was five subtypes and 0.5 percent, and inverse type was 0.12 percent.

  • PDF

Relations between Airway Narrowing and Prevertebral Soft Tissue Swelling after Anterior Cervical Spine Surgery : The Value of Lateral Neck Radiographs

  • Kim, Hee-Seop;Youm, Jin-Young;Kwon, Hyon-Jo;Choi, Seung-Won;Kim, Seon-Hwan;Koh, Hyeon-Song
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • Objective : The authors attempted to evaluate the pattern of the airway narrowing due to prevertebral soft tissue swelling after surgery of the anterior cervical spine and their clinical significances using plain cervical X-ray images. Methods : Twenty-four patients undergoing anterior cervical spine surgery were reviewed from January 2004 to December 2005. Postoperatively, in daily basis, lateral radiograph of the neck was obtained in neutral position. We measured the upper airway diameter above and below the epiglottis level and prevertebral soft tissue diameter every day for a week and finally 2 weeks after surgery using their simple lateral cervical X-ray films. Results : Both airway narrowing and prevertebral soft tissue swelling were maximum in postoperative 2 days, and decreased rapidly in postoperative 7 days. Airway narrowing was aggravated postoperatively but slowly decreased as prevertebral soft tissue swelling diminished. But, the severity of airway narrowing showed no clinical correlations with clinical symptom and radiologic severity. Conclusion : Not all patients who show severe airway narrowing and prevertebral soft tissue swelling on their plain cervical X-ray film complain respiratory insufficiency. But, the patients with undergoing anterior cervical spine surgery should be monitored carefully for respiratory insufficiency, especially during several days following operation because both airway narrowing and prevertebral soft tissue swelling become peak at postoperative 2-3 days.