• Title/Summary/Keyword: soft X-ray

Search Result 406, Processing Time 0.029 seconds

나노 및 Bio 물질 내부구조 비파괴 분석을 위한 현미경 개발 현황

  • 심철무
    • 비파괴검사학회지
    • /
    • 제36권5호
    • /
    • pp.406-416
    • /
    • 2016
  • 바이오와 나노 분야의 비파괴검사는 nm 급의 공간분해능을 요구한다. 바이오와 나노 물질의 내부구조의 비파괴 분석을 위한 공간분해능을 nm급으로 향상시키는Soft X-ray현미경 및 초음파현미경에 대한 기술을 소개한다. 세포생물(Biology)의 단백질구조분석, 수문학(Hydrology)연구, 나노입자거동 등의 연구를 위해서 중성자현미경기술개발 및 현황을 소개하고자 한다. 초음파현미경, Soft X-ray현미경 및 중성자현미경에 대하여 Hybrid 이용자 지원 체계를 구축하여 나노 및 Bio 물질 내부구조 분석기술을 확립하여 지원하고자 한다.

양산물금 점토의 광물학적 특성 (Mineral Properties of Yangsan.Mulkum Clay)

  • 정하익;이용수;진규남;진현식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.75-80
    • /
    • 1999
  • In this study, clay sampled from Yangsan$.$Mulkum site were used to analyze mineral properties. Mineral and chemical properties of clay were investigated through X-ray fluorescence spectrometer(XRF), X-Ray Diffraction(XRD), and Scanning Electron Microscope(SEM) analysis. The result of this test represents that Yangsan$.$Mulkum clay are composed of quartz, albite, anorthite, orthocalse and illite.

  • PDF

A STUDY OF THE DYNAMICAL CROSS CORRELATION FUNCTION IN A BLACK HOLE SOURCE XTE J1550-564

  • SRIRAM, K.;CHOI, C.S.;RAO, A.R.
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.599-601
    • /
    • 2015
  • The short time scale X-ray variability associated with the accretion disk around compact objects is complex and is vaguely understood. The study of the cross correlation function gives an insight into the energy dependent behavior of the variations and hence connected processes. Using high resolution RXTE data, we investigate the dynamical cross correlation function of an observation of a black hole source XTE J1550-564 in the steep power law state. The cross correlation between soft and hard X- ray energy bands revealed both correlated and anti-correlated delays (${\leq}{\pm}15s$) on a correlation time scale of 50 s. It was noticed that the observed delays were similar to the delays between X-ray and optical/IR bands in other black hole and neutron star sources. We discuss the possible mechanisms/processes to explain the observed delays in the dynamical CCF.

고주파 공진형 방식 X-선 발생장치에 관한 연구 (A Study on High Frequency Resonant Type X-ray Generator)

  • 유동욱;하성운;백주원;김종수;김학성;원충연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.209-211
    • /
    • 1995
  • This paper is concerned with High Frequency, High Voltage Generator for X-ray using zero-voltage soft-switching PWM DC-DC high-power converter by Resonant method, which makes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series Resonant full-bridge PWM DC-DC high-power converter operating at a constant frequency;25kHz. The converter output regulation is digitally controlled using DSP (Digital Signal Processor) for obtaining a fast rising time and adjust output voltage within a wide load range.

  • PDF

Spectra of Optical-field Ionized Gases by a Femtosecond Ti:Sapphire Laser

  • Mock, Tomas;Shin, Hyun-Joon;Cha, Yong-Ho;Lee, Dong-Gun;Hong, Kyung-Han;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제2권2호
    • /
    • pp.50-53
    • /
    • 1998
  • We report on the spectroscopic investigation of optical-field ionized plasmas in the soft X-ray spectral region. The experiment was carried out by focusing pulses of the high-power Ti:Sapphire laser with an energy of ~ 40 mJ and time duration of ~30 fs into a gas jet of krypton, xenon, and argon from a pulsed nozzle. Strong soft X-ray emission on lines from ionic stages of $Kr^{7+} , Kr^{8+} , Xe^{7+} , Ar^{7+} , and Ar^{8+}$ is reported. The experimental result was found to be in good agreement with theoretical prediction.

대전된 분체의 정전기제거장치 개발 및 특성에 관한 연구 (A Study for Development and Characteristics of Electrostatic Eliminator for Charged Particles)

  • 정용철;김준삼;이동훈
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.22-30
    • /
    • 2006
  • On this study, we developed the electrostatic eliminator for charged particles in manufacturing process. The characteristics of the electrostatic eliminator were investigated, which is two kinds. The first one is Electrical Corona Discharged Type Ionizer. The second one is Photo Ionizer in using soft X-ray. From the experiment, we have obtained the following results. In case of Electrical Corona Discharged Ionizer, neutralization efficiency of charged particles were approximately saturated to 98% over 6.0kV, but as it is non-explosion proof, can not be used in flammable particle treatment process. While in case of photo Ionizer in using soft X-Ray, neutralization efficiency of charged particles were approximately 95%, and more its structure is explosion proof, could be used in flammable particle treatment process.

Growth of magnesium oxide nanoparticles onto graphene oxide nanosheets by sol-gel process

  • Lee, Ju Ran;Koo, Hye Young
    • Carbon letters
    • /
    • 제14권4호
    • /
    • pp.206-209
    • /
    • 2013
  • Nanocomposites comprised of graphene oxide (GO) nanosheets and magnesium oxide (MgO) nanoparticles were synthesized by a sol-gel process. The synthesized samples were studied by X-ray powder diffraction, atomic force microscopy, transmission electron microscopy, and energy-dispersive X-ray analysis. The results show that the MgO nanoparticles, with an average diameter of 70 nm, are decorated uniformly on the surface of the GOs. By controlling the concentration of the MgO precursors and reaction cycles, it was possible to control the loading density and the size of the resulting MgO particles. Because the MgO particles are robustly anchored on the GO structure, the MgO/GOs nanocomposites will have future applications in the fields of adsorption and chemical sensing.

A Flexible Precise 2D-Image Reconstruction in X-Ray Computed Tomography for Soft Tissues Based On Non-Uniform Sampling Theorem

  • Kim, io-Sasaki;Hirokazu Okaniwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.80.4-80
    • /
    • 2002
  • Performance of the previously proposed 2D-image reconstruction method for soft tissues in x-ray computed tomography is evaluated thoroughly through numerical experiments with 4 assumed absorption rates of different symmetries under practical conditions, and the following special features are made clear: It is quite precise, especially at points where the object taking larger values; about two orders less magnitude errors than the conventional most precise method when no noise existing, without any 1D- or 2D-interpolation. In spite of its high sensitivity to the noises, it is even more precise by about 8dB than the latter, to relative pojection data noise power of 5%.

  • PDF

THE PERIODICITY OF THE SOLAR FLARE PRODUCTION DURING THE ACTIVITY CYCLE 22

  • TOHMURA ICHIROH;TOKIMASA NORITAKA;KUBOTA JUN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.321-322
    • /
    • 1996
  • Using the data on the occurrences of the Ho: and soft X-ray flares for the time interval of January 1, 1986-May :31, 1994, we have studied the middle term(30-300days) pericities of the solar flare production during the activity cycle 22. Power analysis of the time seies of daily H$\alpha$ flare index in the northern hemisphere shows prominent periodicities at 220, 120, 109, and 92 days(see Figures l(a) and l(b)), while in the southern hemisphere, those at 267, 213, 183, 167, and 107 days are apparent, though their peaks are not so distint as those in the northern hemisphere. Periodogram of daily soft X-ray flare index also reveal the periodicities at 279, 205, 164, 117, and 91 days in the northern hemisphere, and at 266, 220, 199, 162, 120, and 100 days in the southern hemisphere. Howeer, the 155-day periodicity reported for the earlier cycles, 19, 20, and 21, could not be confirmed in our analysis. to be submitted to Solar Physics; an extended abstract.

  • PDF

Modified Magnetism at Buried Co/Pd Interface: Depth-Resolved Magnetic Circular Dichroism Study Using Soft X-ray Standing Waves

  • Kim, Sang-Koog;Kortright, J.B.;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • 제5권3호
    • /
    • pp.76-80
    • /
    • 2000
  • Soft x-ray standing waves produced by a multilayer interference substrate add depth-sensitivity to magnetic circular dichroism to resolve changes in Co magnetism across a 10${\AA}$ distance from the Co center to the Co-Pd interface of a Pd/Co/Pd trilayer having in-plane magnetization. Large enhancements of in-plane orbital and spin magnetic moments, as well as the number of d holes, are strongly localized in a thin interface layer. These results provide new insight into the phenomenon of magnetic anisotropy at buried interfaces, and suggest a broad applicability of such standing wave measurements to interface magnetism studies.

  • PDF