• Title/Summary/Keyword: sodium leakage

Search Result 56, Processing Time 0.025 seconds

Dynamic data validation and reconciliation for improving the detection of sodium leakage in a sodium-cooled fast reactor

  • Sangjun Park;Jongin Yang;Jewhan Lee;Gyunyoung Heo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1528-1539
    • /
    • 2023
  • Since the leakage of sodium in an SFR (sodium-cooled fast reactor) causes an explosion upon reaction with air and water, sodium leakages represent an important safety issue. In this study, a novel technique for improving the reliability of sodium leakage detection applying DDVR (dynamic data validation and reconciliation) is proposed and verified to resolve this technical issue. DDVR is an approach that aims to improve the accuracy of a target system in a dynamic state by minimizing random errors, such as from the uncertainty of instruments and the surrounding environment, and by eliminating gross errors, such as instrument failure, miscalibration, or aging, using the spatial redundancy of measurements in a physical model and the reliability information of the instruments. DDVR also makes it possible to estimate the state of unmeasured points. To validate this approach for supporting sodium leakage detection, this study applies experimental data from a sodium leakage detection experiment performed by the Korea Atomic Energy Research Institute. The validation results show that the reliability of sodium leakage detection is improved by cooperation between DDVR and hardware measurements. Based on these findings, technology integrating software and hardware approaches is suggested to improve the reliability of sodium leakage detection by presenting the expected true state of the system.

Yeonggwang #1/2 steam condenser leakage repair works (영광 #1/2 복수기 누수부 보수공사)

  • 이상철;공창식
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.117-119
    • /
    • 2003
  • Power plant efficiency and availability depend greatly on condenser performance. However, during commissioning of Yeonggwang #1/2 steam condenser sodium leakage occurred, because of tube to tubesheet only roll expanding. Therefore this report is explaining that pre-test for the shake of improvement reliable repair processes & selected sampling tube re-expansion in-situ applications.

  • PDF

A Study on the Engineering Properties of Micro Fine Hybrid Silicate Based Grout (마이크로 복합실리카 그라우트의 공학적 특성에 관한 연구)

  • 천병식;김진춘;최영철;정종주;신상재;이홍재
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.63-70
    • /
    • 2000
  • In 1925, H.J. Joosten was the first in the world to use chemical injection grouts composed of sodium silicate and calcium chloride. This unique development prompted the introduction of other chemical grouting techniques. Among these chemical grouting techniques, sodium silicate based grout has been the most widely used in the world, but it has not been generally considered to be a permanent material. Therefore, studies to improve the weak points of sodium silicate based grout have been conducted, and new applications of grout were recently developed. We also developed the micro fine hybrid silicate grout of suspention type which properties are sepecialized as the high strength and durability, according to the reactant of special sodium silicate grout and the high strength hardener. As the results of this study we could derive the 2 times over high strength of Micro fine hybrid Silicate grouting method(MS method) more than that of the ordinary sodium silicate grout. And also we could confirm that the alkali leakage of micro fine hybrid silicate grout is less than that of ordinary sodium silicate grout. So we could get the high strength and durability of hybrid silicate grout are superior to those of ordinary sodium silicate grout.

  • PDF

A STUDY ON THE BLEACHING EFFECTIVENESS OF BLEACHING AGENTS AND THE APICAL LEAKAGE ACCORDING TO THE LOCATION OF THE INTRACORONAL BASE (무수치 표백시 표백제의 성분에 따른 표백효과 및 이장재의 위치에 따른 치근부 누출에 대한 실험적 연구)

  • Shin, Jea-Hyun;Kim, Yong-Kee;Hong, Chan-Ui;Shin, Dong-Hoon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.4 no.1
    • /
    • pp.12-22
    • /
    • 1995
  • The purposes of this study were to compare the bleaching efficacy of sodium perborate when mixed either with Superoxol or distilled water and to evaluate the efficacy of different location of intracoronal base on the presence of apical leakage of tested bleaching agents. Forty eight extracted human permanent incisors were stained via whole blood and canal fillings with conventional gutta percha were performed after routine biomechanical perparations. The experimental intracoronal base was placed either at the cementoenamel junction(group 3, 4) or 2mm below cementoenamel junction(group 1, 2). Walking bleaching was performed by two different combinations of bleaching agents : sodium perborate with distilled water in group 1, 3 and sodium perbrate with Superoxol in group 2, 4. The roots of the teeth were evaluated for the presence of color change to assess the leakage of bleaching agents and the cervical one-thirds of the crown were evaluated for bleaching effect from the whiteness Indea calculated by spectrophotometer. The results were as follows : 1. At the end of 12 days, all the sample teeth demonstrated the increase of Whiteness Index at cervical 1/3 of crown although there were some minor differences among groups. 2. Regardless of location of the base, sodium perborate with superoxol(group 2, 4) showed better results in bleaching than the sodium perborate with distilled water(group 1, 3). 3. Bleaching agent leaked into the root area when the base was placed 2mm below cementoenamel junction but no leakage was found when the base was placed at the cementoenamel junction.

  • PDF

A STUDY ON THE BLEACHING EFFECTIVENESS OF BLEACHING AGENTS AND THE APICAL LEAKAGE ACCORDING TO THE LOCATION OF THE INTRACORONAL BASE (무수치 표백시 표백제의 성분에 따른 표백효과 및 이장재의 위치에 따른 치근부 누출에 대한 실험적 연구)

  • Shin, Jea-Hyun;Kim, Yang-Kee;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.145-155
    • /
    • 1993
  • The purposes of this study were to compare the bleaching efficacy of sodium perborate when mixed either with Superoxol or distilled water and to evaluate the efficacy of different location of intracoronal base on the presence of apical leakage of tested bleaching agents. Forty eight extracted human permanent incisors were stained via whole blood and canal fillings with conventional gutta percha were performed after routine biomechanical perparations. The experimental intracoronal base was placed either at the cementoenamel junction(group 3, 4) or 2mm below cementoenamel junction(group 1, 2). Walking bleaching was performed by two different combinations of bleaching agents : sodium perborate with distilled water in group 1, 3 and sodium perbrate with Superoxol in group 2, 4. The roots of the teeth were evaluated for the presence of color change to assess the leakage of bleaching agnets and the cervical one-thirds of the crown were evaluated for bleaching effect from the whiteness Indea calculated by spectrophotometer. The results were as follows : 1. At the end of 12 days, all the sample teeth demonstrated the increase of Whiteness Index at cervical 1/3 of crown although there were some minor differences among groups. 2. Regardless of location of the base, sodium perborate with superoxol)group 2, 4) showed better results in bleaching than the sodium perborate with distilled water(group 1, 3). 3. Bleaching agent leaked into the root area when the base was placed 2mm below cementoenamel junction but no leakage was found when the base was placed at the cementoenamel junction.

  • PDF

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

Signal processing method based on energy ratio for detecting leakage of SG using EVFM

  • Xu, Wei;Xu, Ke-Jun;Yan, Xiao-Xue;Yu, Xin-Long;Wu, Jian-Ping;Xiong, Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1677-1688
    • /
    • 2020
  • In the sodium-cooled fast reactor, the steam generator is a heat exchange device between sodium and water, which may cause leakage, resulting in a sodium-water reaction accident, which in turn affects the safe operation of the entire nuclear reactor. To this end, the electromagnetic vortex flowmeter is used to detect leakage of the steam generator and its signal processing method is studied in this paper. The hydraulic experiment was carried out by using water instead of liquid sodium, and the sensor output signal of the electromagnetic vortex flowmeter under different gas injection volumes was collected. The bubble noise signal is reflected by the base line of the sensor output signal. According to the relationship between the proportion of the bubble noise signal in the sensor output signal and the gas injection volume, a signal processing method based on the energy ratio calculation is proposed to detect whether the water contains bubbles. The gas injection experiment of liquid sodium was conducted to verify the effectiveness of the signal processing method in the detection of bubbles in sodium, and the minimum detectable leak rate of water in the steam generator was detected to be 0.2 g/s.

Physicochemical Characterization and In Vivo Evaluation of Thermosensitive Diclofenac Liquid Suppository

  • Yong, Chul-Soon;Choi, Young-Kwon;Kim, Yong-Il;Park, Byung-Joo;Quan, Qi-Zhe;Rhee, Jong-Dal;Kim, Chong-Kook;Choi, Han-Gon
    • Archives of Pharmacal Research
    • /
    • v.26 no.2
    • /
    • pp.162-167
    • /
    • 2003
  • Liquid suppository systems composed of poloxamers and bioadhesive polymers were easy to administer to the anus and mucoadhesive to the rectal tissues without leakage after the dose. However, a liquid suppository containing diclofenac sodium could not be developed using bioadhesive polymers. since the drug was precipitated in this preparation. To develop a liquid suppository system using sodium chloride instead of bioadhesive polymers, the physicochemical properties such as gelation temperature, gel strength and bioadhesive force of various formulations composed of diclofenac sodium, poloxamers and sodium chloride were investigated. Furthermore, the pharmacokinetic study of diclofenac sodium delivered by the liquid suppository was performed. Diclofenac sodium significantly increased the gelation temperature and weakened the gel strength and bioadhesive force, while sodium chloride did the opposite. The liquid suppositories with less than 1.0% of sodium chloride, in which the drug was not precipitated, were inserted into the rectum without difficulty and leakage. Furthermore, liquid suppository gave significantly higher initial plasma concentrations and faster Tmax of diclofenac sodium than did solid suppository, indicating that drug from liquid suppository could be absorbed faster than that from solid one in rats. Our results suggested that a thermosensitive liquid suppository system with sodium chloride and poloxamers was a more physically stable, convenient and effective rectal dosage form for diclofenac sodium.

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

Fundamental evaluation of hydrogen behavior in sodium for sodium-water reaction detection of sodium-cooled fast reactor

  • Tomohiko Yamamoto;Atsushi Kato;Masato Hayakawa;Kazuhito Shimoyama;Kuniaki Ara;Nozomu Hatakeyama;Kanau Yamauchi;Yuhei Eda;Masahiro Yui
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.893-899
    • /
    • 2024
  • In a secondary cooling system of a sodium-cooled fast reactor (SFR), rapid detection of hydrogen due to sodium-water reaction (SWR) caused by water leakage from a heat exchanger tube of a steam generator (SG) is important in terms of safety and property protection of the SFR. For hydrogen detection, the hydrogen detectors using atomic transmission phenomenon of hydrogen within Ni-membrane were used in Japanese proto-type SFR "Monju". However, during the plant operation, detection signals of water leakage were observed even in the situation without SWR concerning temperature up and down in the cooling system. For this reason, the study of a new hydrogen detector has been carried out to improve stability, accuracy and reliability. In this research, the authors focus on the difference in composition of hydrogen and the difference between the background hydrogen under normal plant operation and the one generated by SWR and theoretically estimate the hydrogen behavior in liquid sodium by using ultra-accelerated quantum chemical molecular dynamics (UA-QCMD). Based on the estimation, dissolved H or NaH, rather than molecular hydrogen (H2), is the predominant form of the background hydrogen in liquid sodium in terms of energetical stability. On the other hand, it was found that hydrogen molecules produced by the sodium-water reaction can exist stably as a form of a fine bubble concerning some confinement mechanism such as a NaH layer on their surface. At the same time, we observed experimentally that the fine H2 bubbles exist stably in the liquid sodium, longer than previously expected. This paper describes the comparison between the theoretical estimation and experimental results based on hydrogen form in sodium in the development of the new hydrogen detector in Japan.