• Title/Summary/Keyword: snow control material facilities

Search Result 3, Processing Time 0.017 seconds

Planning Guidance for Snow Control Material Storage Facilities Based on Case Studies (사례조사를 통한 제설전진기지 시설기준에 관한 연구)

  • Kim, Geun-Young;Kim, Hee-Jea;Park, U-Yeol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • The snow control storage facilities have the physical requirements that are an anti-icing and deicing operations. They are efficiently and quickly performed, and composed of a vehicle depot for the snow removal equipment and truck, anti-icing and deicing chemical storages, and the control utilities. This study is to investigate the planning guidance of foreign countries, and the actual conditions of the snow control chemical storage facilities for expressway, the national highway and the local road, and is to suggest the planning guidelines. As some of the authorities have no fixed structures for the snow control storage, this study analyze the 5 cases constructed lately. From the result of the case studies, the operations performed in the snow control storage facilities and drawback of the facilities are analyzed with respect to layout, size, plan, and structure, and the improvement planning guidance is also suggested.

Evaluation of Outdoor Community Facility in Rental Apartment For Community Space Activation (커뮤니티공간 활성화를 위한 임대아파트의 외부 커뮤니티시설 계획 특성에 관한 연구)

  • Hwang, Yeon Sook;Lee, Song Hyun;Eo, Sung-sin
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.69-76
    • /
    • 2009
  • The purpose of this study is to provide basic data needed for planning and designing apartment community facilities in order to vitalize rental apartments. Outdoors community facilities of six rental apartments in Seoul were examined. The results are as follows. Firstly, the conditions of planning characteristics showed that the convenience is ranked as the highest priority of planning, compared to safety, friendliness and finally comfortableness. Community facilities are connected with the apartments and sidewalk providing convenient access for all apartment residents, there was little regard given to the features of comfortableness. Secondly, comfortableness of community facilities were shown to the lowest, compared to any characteristics. It is not easy to control noise and privacy in facility, and there are lack of near community facilities, for washing hands, drinking water and shielding from snow or rain, respectively. Thirdly, green facilities were shown to the highest applied friendliness more than other facilities. They were well outfitted with water space and gardening spaces, and robustly applied environment friendly materials and colors. Fourthly, resting facilities were shown to the lowest applied safety more than other facilities. Structure and material of facility are favorable but there is an absence of nonskid material and night-lightening system.

Field Survey on the Maintenance Status of Greenhouses in Korea (온실의 유지관리 실태조사 분석)

  • Choi, Man Kwon;Yun, Sung Wook;Kim, Hyeon Tae;Lee, Si Young;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.148-157
    • /
    • 2014
  • The purpose of this study was to investigate greenhouse maintenance by farms by looking into greenhouses across the nation for greenhouse specification, disaster-resistance greenhouse construction, types and degree of damage due to natural disasters, pre-inspection in case of typhoon or heavy snow forecast, and fire-fighting facilities to prevent a fire. The findings were summarized as follows: as for greenhouse specification, the highest proportion of them were 90 m or longer both in single- and multi-span greenhouses in terms of length; 8 m or wider and 7.0~7.9 m in single- and multi-span greenhouses, respectively, in terms of width; 1.5~1.9 m and 2.0~2.9 m in single-and multi-span greenhouses, respectively, in terms of height; and 3.0~3.9 m and 6 m in single- and multi-span greenhouses, respectively, in terms of diameter. As for disaster-resistance greenhouses, farmers were reluctant to install such greenhouses. The low distribution of disaster-resistance greenhouses was attributed to the greenhouses built dependent on the old practice, the greenhouses already completed, and relatively high construction costs. As for damage by natural disasters, greenhouses were subject to more damage by typhoons than heavy snow. They mainly inspected the ceiling and side windows, entrances, and fixation bands for covering materials in case of typhoon forecast and the heating devices in case of heavy snow forecast. As for repair methods for greenhouse pipe corrosion, they preferred partial replacement to painting and did not use stiffeners for structures to prevent a natural disaster in most cases. As for the maintenance of greenhouse covering materials, most farmers inspected their sealing property but did not clean the coverings for light transmission. The destruction of structural materials can be prevented by eliminating greenhouse covering materials during a typhoon, but they were not able to do so because of the covering material replacement costs and the crops they were growing. The study also examined whether greenhouse farms had fire-fighting facilities to prevent a fire and found that they lacked the perception of greenhouse fire prevention to a great degree.