• 제목/요약/키워드: smart substation

검색결과 33건 처리시간 0.028초

제주지역 계통운전조건을 고려한 풍력발전단지용 최소 BESS용량 산정 (Estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Isalnd)

  • 진경민;김승현;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.39-45
    • /
    • 2013
  • This paper presents the estimation of minimum BESS capacity for regulating the output of wind farms considering power grid operating condition in Jeju Island. To analyze the characteristics of wind farm outputs with a BESS, the real data of wind farms, Sung-San, Sam-dal and Hang-Won wind farm, located in the eastern part of Jeju island is considered. The wind farms are connected to Sung-san substation to transfer the electric power to Jeju power grid. Consequently, at PCC (Point of Common Coupling), it can see a huge wind farm connected to the substation and thus it can be expected that the smoothing effect is affected by not only the different wind speeds for each area but also the different mechanical inertia of wind turbines. In this paper, two kinds of simulation have been carried out. One is to analyze the real data of wind farm outputs during a winter season, and the other is to connect a virtual BESS to eliminate the unintended generating power changes by the uncontrolled wind farm outputs as shown in the former data. In the conclusion, two kinds of simulation results show that BESS installed in the substation is more efficient than each wind farms with BESS, respectively.

IEC61850 기반의 통신방식을 이용한 스마트 배전운영시스템용 보호협조 알고리즘 개발 (Development of Protection Coordination Algorithm for Smart Distribution Management System using Communication Method based on IEC61850)

  • 추철민;윤상윤;권성철;추경용;진영규;최면송
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1412-1419
    • /
    • 2012
  • In this paper, we propose the protection coordination algorithm using communication methode based on IEC 61850. The communication protocol in power distribution management system has been issued by IEC standard, IEC61850 of them, which was made for substation automation system, has researched to apply into power distribution system, even though the standard is not a suitable for the system. In smart distribution management system' launched in 2009, the communication network based on the ethernet network for IEC 61850 has been designed to apply the self-healing concept, which is to perform the system protection through the communication between remote terminal units(RTU) according to the standard. However, it is first time to apply the scheme in the real. Thus, this paper proposed the protection algorithm and consideration for applying communication method and introduced the result of demonstration.

SG 환경에서 CoAP 기반 M2M 게이트웨이 (M2M Gateway based on CoAP in SG Environment)

  • 신인재;박지원;이상훈;송병권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.47-48
    • /
    • 2015
  • As the power system develops rapidly into a smarter and more flexible state, so must the communication technologies that support it. Machine to machine (M2M) communication in Smart Grid environment has been discussed in European Telecommunications Standards Institute (ETSI). The power system is not easily replaceable, due to system replacement cost. The M2M gateway is required in other to improve interoperability in M2M environment. The Distributed Network Protocol 3.0 (DNP3.0) is the most important standard in the SCADA systems for the power. It has been used for device data collection/control in Substation Systems, Distribution Automation System. If the DNP3.0 data model is combined with a set of contemporary web protocols, it can result in a major shift. We selected Constrained Application Protocol (CoAP) based on RESTful as M2M protocol. It is a specialized web transfer protocol for use with constrained nodes and constrained networks. We have used the OPNET Modeler 17.1 in order to verity the SOAP versus CoAP. In this paper, we propose the CoAP-based M2M Gateway to Distribution Automation system using DNP3.0 in Smart Grid Environment.

  • PDF

스마트 그리드를 위한 샘플 값들의 트래픽 발생 방안 (Traffic Generation Method of Sampled Values for Smart Grid)

  • 황성호;박경원;박정도;송한춘;박제도
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.225-230
    • /
    • 2015
  • 본 논문에서는 네트워크 시뮬레이터 ns-3의 에뮬레이션 기능과 실제 통신장비를 결합하여, IEC 61850 SV(Sampled Values) 트래픽을 발생시키는 방안을 제시한다. SV 트래픽 발생과 수신은 네트워크 시뮬레이터 ns-3의 에뮬레이션 기능을 이용하고, 통신망은 실제 통신장비인 스위치들을 사용한다. 그리고 Wireshark를 이용하여 발생한 SV 트래픽 프레임들을 분석하였고, SV 트래픽 프레임들이 정확히 발생되는 것을 확인하였다. 본 논문에서 제안한 SV 트래픽 발생 방안은 실제 변전소 환경하에서 다양한 SV 트래픽들을 발생시킬 때 유용하게 활용될 수 있을 것이다.

Communication Architecture of the IEC 61850-based Micro Grid System

  • Yoo, Byong-Kwan;Yang, Seung-Ho;Yang, Hyo-Sik;Kim, Won-Yong;Jeong, Yu-Seok;Han, Byung-Moon;Jang, Kwang-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.605-612
    • /
    • 2011
  • As the power grids are integrated into one big umbrella called a "smart grid," communication protocol plays a key role in successful operations. The successful deployment of smart grid interoperability is a major hurdle that must be overcome. The micro grid, a small power system that distributes energy resource, is operated in diverse regions. Different vendors use different communication protocols in the operation of the micro grid. Recently, the IEC 61850 has been legislated to solve the interoperability problems in power utility automation. The present paper presents a micro grid system based on the IEC 61850 protocol. It consists of a micro grid monitoring system, a protocol converter that transforms serial data to IEC 61850 data, and distributed energy resource controllers for diverse DER nodes. A developed communication gateway can be deployed for DER controllers with serial links to exchange data with IEC 61850-based devices. The gateway can be extended to IEC 61850-based distribution automation systems, substation automation systems, or SCADA.

Modeling and Simulation using Simulink and SimPowerSystem of optimized HTS FCL location in a Smart Grid having a Wind Turbine connected with the grid

  • Khan, Umer-Amir;Lee, Sang-Hwa;Seong, Jae-Kyu;Lee, Bang-Wook
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.17-20
    • /
    • 2010
  • A considerable amount of research material discussing designs and properties of High Temperature Superconducting Fault Current Limiter (HTS FCL) is available. However, a shortage of research concerning positioning of HTS FCL in power grid is felt. In this paper a feasibility study of HTS FCL positioning in Smart Grid through simulation analysis is carried out. A complete power network (including generation, transmission and distribution) is modeled in Simulink / SimPowerSystems. A generalized HTS FCL is also designed by integrating Simulink and SimPowerSystem blocks. The distribution network of the model has a wind turbine attached to it forming a micro grid. Three phase fault have been simulated along with placing FCL models at key points of the distribution grid. It is observed that distribution grid, having distributed generation sources attached to it, must not have a single FCL located at the substation level. Optimized HTS FCL location regarding the best fault current contribution from wind turbine has been determined through simulation analysis.

초전도케이블/한류기 실계통 적용 변전소 및 설치위치 선정 기술검토 (Determination of a Substation and Installation Site for applying Superconducting Cable/FCL to Real Power Grid)

  • 양병모;원영진;김병헌;강지원;윤재영;이승렬;문영현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.55-59
    • /
    • 2009
  • In attempts to closely study the effect of high efficiency, friendly environment HTS(High Temperature Superconducting) cable and SFCL(Superconducting Fault Current Limiters) on power system, several projects were carried out around the world. Promising results have been achieved in terms of cable capacity and reliability. commercial HTS cable and SFCL, however, must not only be only be feasible, but meet practical requirements as well. To facilitate the transition of HTS cable technology from the Lab. to the Real Grid, a New project for applying 22.9kV HTS cables and SFCL to the commercial Power Grid supported by Government has just started in KEPCO. Target of this project is to operate two 22.9kV, 50MVA, 150MVA HTS cables and two 22.9kV 630A, 3000A SFCL in a KEPCO Grid in order to demonstrate its reliability and stable operation. This paper will present the technology for selecting appropriate site and its plan for installation & operating of 22.9kV HTS cables & SFCL in KEPCO Grid.

[논문철회]전력계통 네트워크 통신방식 변화에 따른 사이버위협 분석 및 대응방안 제시 ([Retracted]Cyber Threat Analysis on Network Communication in Power System and Countermeasures Suggestions)

  • 지일환;전승호;서정택
    • 스마트미디어저널
    • /
    • 제12권2호
    • /
    • pp.91-102
    • /
    • 2023
  • 전력거래소 에너지 관리 시스템(Energy Management System, EMS)는 발전소 및 변전소와 통신을 수행하며 전력공급의 안정성 및 연속성, 실시간성, 경제성을 위하여 송·변전시스템의 변전소 및 발전소 운전상태를 모니터링하고 발전소와 변전소를 제어한다. 현재 전력거래소 EMS는 발전소 및 변전소와 시리얼 통신기반 DNP(Distributed Network Protocol) 3.0 프로토콜을 기반으로 통신을 수행하고 있다. 하지만, 시리얼 통신장비 수급의 어려움, 신재생 발전설비를 포함한 통신을 수행할 신규 설비의 지속적인 증가로 인해 시리얼 포트 및 모뎀의 설치 공간 부족 등의 문제가 제기되고 있다. 이에 본 논문에서는 전력거래소 EMS의 기존 시리얼 통신방식 대신 TCP/IP기반의 통신 방식을 제시하며, 통신방식 변화에 따른 발생 가능한 보안 위험 분석 및 보안 위험에 대한 대응방안을 제시한다.

Analyse the Electric field of symmetrical and asymmetrical concentric electrodes

  • Singhasathein, Arnon;Suwanapingkarl, Pasist;Phanthuna, Nattaphong;Ted-I, Taweesak;Teevarangsan, Teepagon;Yumonthian, Tananan
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.114-119
    • /
    • 2015
  • The different between two potential voltages can cause the electric field. The electric field is normally distributed along the radius of electrode, and hence it depends on the shape of electrodes. This paper analyses the distribution factor of electric field of symmetrical and asymmetrical concentric electrodes by using Finite Element technique. This allows an analysis the optimum safety clearance distance between two concentric electrodes. The symmetrical concentric electrode refers to Spherical-Spherical concentric electrodes and Cylindrical-Cylindrical concentric electrodes. It must be noted that the symmetrical electrodes are mostly applied for Gas Insulated Substation (GIS) equipments. The asymmetrical electrodes mention to Spherical (inner)-Cylindrical (outer) concentric electrodes and Cylindrical-Cube concentric electrodes, which present as the connection point of High Voltage (HV) cable. The simulations is also complies with the existing standards and regulations in order to ensure the accurate results.

RMT: A Novel Algorithm for Reducing Multicast Traffic in HSR Protocol Networks

  • Nsaif, Saad Allawi;Rhee, Jong Myung
    • Journal of Communications and Networks
    • /
    • 제18권1호
    • /
    • pp.123-131
    • /
    • 2016
  • The high-availability seamless redundancy (HSR) protocol is one of the most important redundancy IEC standards that has garnered a great deal of attention because it offers a redundancy with zero recovery time, which is a feature that is required by most of the modern substation, smart grid, and industrial field applications. However, the HSR protocol consumes a lot of network bandwidth compared to the Ethernet standard. This is due to the duplication process for every sent frame in the HSR networks. In this paper, a novel algorithm known as the reducing multicast traffic (RMT) is presented to reduce the unnecessary redundant multicast traffic in HSR networks by limiting the spreading of the multicast traffic to only the rings that have members associated with that traffic instead of spreading the traffic into all the network parts, as occurs in the standard HSR protocol. The mathematical and the simulation analyses show that the RMT algorithm offers a traffic reduction percentage with a range of about 60-87% compared to the standard HSR protocol. Consequently, the RMT algorithm will increase the network performance by freeing more bandwidth so as to reduce HSR network congestion and also to minimize any intervention from the network administrator that would be required when using traditional traffic filtering techniques.