• Title/Summary/Keyword: small-sized vessel

Search Result 44, Processing Time 0.021 seconds

An Investigation on the Optimal Ship Size for Chemical Tankers by Main Shipping Routes (케미컬 탱커선 운항노선별 최적선형에 관한 연구)

  • Kim, Jae-Ho;Kim, Taek-Won;Woo, Su-Han
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.439-450
    • /
    • 2015
  • This study objects to find characteristics in chemical tanker markets and to determine optimal chemical tanker size using a total shipping cost in main trading route of asia chemical tankers .Precedent studies of determination of the optimal ship size and case studies about chemical tankers was carried out and tried to introduce a cost model which is applicable to chemical tanker. This study is dependant on numerical analysis and involves scenario analysis to minimize sensitivity of results. This analysis shows as follows. First, 12,000DWT tanker is an optimal size on the 'Far East-Middle East' services, 9,000DWT tanker is a most competitive on the 'Far East-South East Asia' services and 3,000DWT tanker is a most economic size on the 'Inner Far East' services at average market situation. Second, the bigger size of chemical tanker, the more competitive advantage the tanker will obtain when bunker fuel prices rise. Small size ship gets more competitive during bunker prices down. Third, market fluctuation of time charter rate for chemical tanker is less than 20% against its average time charter hire which means less volatile. And tanker's competitiveness per each size is remained mostly same when time charterer rates rise at same proportion. Fourth, bigger size chemical tankers have cost advantages when tanker's quantity of each part cargo increase. And small-sized tanks are more competitive when part cargo scales decrease. For the last, ship's port stay strongly influences on the determination of the optical tanker size. When vessel has shorter port stay, bigger-sized tanker will be more competitive and even can be competitive if applies in short voyage as well.

A Study on the Fishing Efficiency of the Jigging Gear Neon Flying Squid , Ommastrephes Bartrami in the North Pacific (북태평양 빨강오징어 채낚기의 조획성능에 관한 연구)

  • 오희국
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.150-160
    • /
    • 1994
  • Drift gillnet fishery for neon flying squid in the North pacific was one of the major pelagic fisheries of Korea until 1992, its annual catch was 79, 000M/T as average during 1988-1992, but moratoriumed since 1993 according to the decision of UN. Therefore, for the developing of the new fishing gear for the squid, the seven types of rip hook by automatic squid jigging machine were experimented by the korean research vessel Pusan 851 (G/T 1.126, 2.600 PS) in the North Pacific (38 $^{\circ}$30'-43 $^{\circ}$N, 152 $^{\circ}$E-178 $^{\circ}$W) from July 6. 1993 to August 31. 1993. The investigation on catch rate, dropout rate, and catch condition of the rip hooks related to the fishing lamp power for aggregating the squid were carried out during the period. The results obtained are as follows: The composition of catch by automatic squid jigging machine was 83.9% for neon flying squid. 15.5% for boreopacific gonate squid. 0.6% for boreal clubhook squid, and 0.01% for luminous flying squid. The catch rate of neon flying squid was 94.6% in 13.6-18.3$^{\circ}C$ of surface water temperature and 5.4% in others. The higher catch rate of neon flying squid was made in the range 13.6-18.3$^{\circ}C$ of temperature at the surface and about 1$0^{\circ}C$ of temperature at the 100m layer. The CPUE of neon flying squid in the 13.6-18.3$^{\circ}C$ of surface water temperature was ranged 0.8-11.8kg (8.7kg as average). The mantle length and body weight of neon flying squid caught in the experiment were ranged 18.3-51.3 cm, 140-3, 980g and mean mantle length and mean body weight were 29.4cm, 972g respectively. The catch rate of neon flying squid was the highest at dawn with a value of 25.0% of the total catch. The body weight of neon flying squid caught by the D type hooks was 1.7 times more than that of the A type hooks. The dropout rate of neon flying squid caught by the seven types hooks was 7.9-57.5% (19.0% as average), and dropout rate of the D type hooks was 7.9% with 2.7 times decrease than that of the A type hooks. The catch efficiency of small sized neon flying squid in case of using on-off switch method on fishing lamp in 15 minutes intervals was 2.6 times higher than that of the on-switch method with same fishing lamp power.

  • PDF

A Study on Safe Operation Standards of Piers based on Mooring Safety Evaluation to Increase Efficiency of Local Management Trade Ports (지방관리 무역항의 효율성 증대를 위한 계류안전성 평가 기반의 부두 안전운용기준에 관한 연구)

  • Kim, Seungyeon;Yu, Yongung;Lee, Yunsok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.1
    • /
    • pp.107-116
    • /
    • 2022
  • Local management trade ports are small-sized trade ports, which require active operation to strengthen the local cities' economic power and enhance the local industries' added value. In addition, local management trade ports should berth ships larger than the existing ships to increase efficiency and keep up with the international trend where ships are becoming larger. Furthermore, they should also prepare operating standards. This study selected Okgye Port among local management trade ports. We performed a mooring safety simulation evaluation according to the scenario where a 50,000 DWT vessel is moored at the current 20,000 DWT class pier. The emergency departure criteria were 27kts at 3.2s of wave period and 22kts at 5.0s of wave period at the existing pier. Results showed that mooring limit condition increased by about 50% to 41kts at 3.2s of wave period and 36kts at 5.0s of wave period. This study can be used for strengthening mooring facilities and setting operational standards for safe port operation when large ships are berthing.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.