• Title/Summary/Keyword: small-scale H

Search Result 422, Processing Time 0.031 seconds

A small-scale membrane electro-dialyser for domestic use

  • Chaalal, Omar;Hossain, Md.M.
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.43-52
    • /
    • 2015
  • A small-scale electro-dialysis system was constructed for domestic use. It is composed of six compartments in which five special polystyrene ionic membranes are housed. A series of experiments on the transport of sodium and chloride ions through polystyrene membranes was performed and the effects of electric current and voltage on the pH of water were investigated. This electrodialyser could reduce the NaCl content to an acceptable level (5307 mg/L) when water containing 9945 mg/L of sodium chloride is fed to the electrodialyser. The reduction was by the action of direct current 60 mA/100 mA when a 15 V / 20 V potential is maintained across the membrane. The results showed that the pH of the treated water attained a value in the range of 7-8, with the chloride concentration of 5307 mg/L when the voltage was in the range of 20 volts. This was achieved when two of the small-scale electro-dialysers were placed in series and the solutions from the respective compartments were mixed. This is considered useful because this complies to the requirement of drinking water standard both in terms of chloride and pH. Therefore, this type electrodialyserhas the potential for domestic uses in isolated houses where potable water supply is not available.

SnSA Design and Embodiment for ESM of Small Scale Network (소규모 네트워크의 통합보안관제를 위한 SnSA 설계 및 구현)

  • 이동휘;신영준;김귀남
    • Convergence Security Journal
    • /
    • v.3 no.2
    • /
    • pp.85-97
    • /
    • 2003
  • At the end of last January, 2003, a domestic top-level domain name server (DNS) shut down the server and it caused the wired and wireless internet services to be completely paralyzed in the aftermath of a virus attack incurring a various range of losses nationwide. The main reason of this event is the lack of our awareness of cyber security. In particular, in the small-scale network, there are few security administrators and no operating devices to protect information as well. Under this circumstance, using ESM center to service real-time security supervision and correspondence for network, it can be one option. However, due to the economic efficiency, most of security systems have been being developed focusing on the large-scale network first. Therefore, ESM centers which inspect security state of network concentrate on IDC or large-scale network services. This dissertation studies economical ESM service by designing exclusive SnSA for small-scale network for widespread use. Firstly, network invasion feeler function N_SnSA and host invasion feeler function H_SnSA are embodied to collect more informations in the small-scale network. Secondarily, the existing vulnerability is studied to find the solutions linked with a low cost to a Public center such as Kyonggi Univ ESM center.

  • PDF

Flow and Temperature Characteristics in a Circular Impinging Jet (원형 충돌 제트에서의 유동 및 온도 특성)

  • Kim Jungwoo;Choi Haecheon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.237-240
    • /
    • 2002
  • In the present study, we perform LES of turbulent flow and temperature fields in a circular impinging jet at Re=5000 for two cases of H/D=2 and 6 (H denotes the distance between the jet exit and flat plate, and D does the diameter of the jet exit). In the case of H/D=2, the regular vortical structures observed in free jet do not exist because of the smaller distance than the potential core. The Nusselt number on the wall is largest at $r/D{\cong}10.67$ where vortex rings Impinge. At $r/D{\cong}1.5{\~}2.0$, the vortex rings induce the secondary vortices, resulting in a secondary peak in the Nusselt number there. In the case of H/D=6, the vortex rings change into three-dimensional vortical structures and the small-scale vortices impinge on the flat plate. The increase of turbulent intensity due to small-scale vortices results in the largest Nusselt number at the stagnation point.

  • PDF

Performance Test of a Catapillar Track-Hydroturbine (무한궤도 수차의 성능시험)

  • Lee, Hyeon-Gu;Kim, Hyeon-Jin;Kim, Hyeon-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.237-243
    • /
    • 1996
  • Current low head and small scale hydroturbines have limitations in the minimum required head and flow rate for efficient operation. This study attempts to develop a new concept hydroturbine which is expected to run efficiently even in very low head and small flow rate, so that the limitations on the conventional small scale hydropower could be alleviated and competition with other alternative energy sources in the economic respect could be attained. A small scale catapillar track- hydroturbine was fabricated and the performance test was carried out in a water tunnel over the head range of H = 0.8 m ~ 1.26 m. The peak turbine efficiency was 41.3% at the speed ratio of 0.6, and the turbine loss was mostly due to the friction at the chain drive used for power transmission from the runner to the shafts. This type of turbine is expected to become competitive when some improvement in the power transmission mechanism is made.

Spray Characteristic of Pressure-Swirl Nozzles Used in Small Scale Burner (기존 소형버너용 압력-선회노즐의 분무특성)

  • Lee, D.H.;Wang, W.W.;No, S.Y.
    • Journal of ILASS-Korea
    • /
    • v.8 no.3
    • /
    • pp.27-32
    • /
    • 2003
  • It is important to improve the efficiency of the existing small scale burner which used in agricultural product dry system and gardening dry system. In order to economize fuel Consumption and decrease the exhaust emission especially $CO_2$, the better design for the small scale burner is needed. Spray characteristics are the essential element for the design. Macroscopic spray characteristics such as spray angle and breakup length were measured. SMD which is contained the Microscopic spray characteristics was measured too. SMD was measured at 8mm, I2mm, I6mm downstream of the nozzle tip for both Hago and Danfoss nozzles by the Malvern Particle Sizer.

  • PDF

Cosmological Tests using Redshift Space Clustering in BOSS DR11

  • Song, Yong-Seon;Sabiu, Cristiano G.;Okumura, Teppei;Oh, Minji;Linder, Eric V.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.43.3-44
    • /
    • 2015
  • We analyze the clustering of large scale structure in the Universe in a model independent method, accounting for anisotropic effects along and transverse to the line of sight. A large sample of 690,000 galaxies from The Baryon Oscillation Spectroscopy Survey Data Release 11 are used to determine the Hubble expansion H, angular distance D_A, and growth rate GT at an effective redshift of z=0.57. After careful bias and convergence studies of the effects from small scale clustering, we find that cutting transverse separations below 40 Mpc/h delivers robust results while smaller scale data leads to a bias due to unmodelled nonlinear and velocity effects. The converged results are in agreement with concordance LCDM cosmology, general relativity, and minimal neutrino mass, all within the $68{\backslash}%$ confidence level. We also present results separately for the northern and southern hemisphere sky, finding a slight tension in the growth rate -- potentially a signature of anisotropic stress, or just covariance with small scale velocities -- but within $68{\backslash}%$ CL.

  • PDF

A Study on the Treatment of Wastewater from Small-scale dyehouse (소규모 염색공장 폐수의 처리에 관한 연구)

  • 이준현;허항록;김광진;김민영;신재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF

High-Temperature Corrosion of T92 Steel in N2/H2O/H2S-Mixed Gas

  • Shi, Yuke;Kim, Min Jung;Park, Soon Yong;Abro, M. Ali;Yadav, Poonam;Lee, Dong Bok
    • Corrosion Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.125-128
    • /
    • 2016
  • The ASTM T92 steel was corroded at $600^{\circ}C$ and $800^{\circ}C$ at 1 atm of $N_2/3.1%H_2O/2.42%H_2S-mixed$ gas. The formed scales were thick and fragile. They consisted primarily of the outer FeS scale and the inner (FeS, $FeCr_2S_4$)-mixed scale containing a small amount of the $Cr_2O_3$ scale. This indicated that corrosion occurred mainly via sulfidation rather than oxidation due to the $H_2S$ gas. Since FeS was present throughout the whole scale, T92 steel was non-protective, displaying high corrosion rates.

Enhancement of Turbulent Heat Transfer of the Cooling System in Nuclear Reactor by Large Scale Vortex Generation

  • Chun, Kun-Ho;Park, Jong-Seok;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.77-84
    • /
    • 2001
  • Experimental and computational studies were carried out to investigate the turbulent heat transfer enhancement of the cooling system in nuclear reactor by large scale vortex generation. The large scale vortex motion was generated by rearranging the inclination angels of mixing vanes to the coordinate direction. Axial development of mean and turbulent velocities in the subchannels were measured by the 2-color LDV system. Eddy diffusivity concept based on $\kappa{-}\varepsilon$ model was employed to calculate the turbulent heat and momentum transfers in the subchannel. The turbulences generated by split mixing vanes has small length scales so that they maintain only about $10D_H$ after the spacer grid. On the other hand, the turbulences generated by the large scale vortex motions continue longer and remain up to $25D_H$ after the spacer grid.

  • PDF

Turbulent Enhancement of the Cooling System of Nuclear Reactor by Large Scale Vortex Generation in a Nuclear Fuel Bundles (원자로 연료봉내 대형 와유동에 의한 원자로 냉각제 시스템의 난류 증진)

  • 전건호;박종석;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1004-1011
    • /
    • 2000
  • Experimental and computational studies were carried out to confirm the turbulent enhancement of the cooling system of nuclear reactor by large scale vortex generation in nuclear fuel bundle. The large scale vortex motions were generated by rearranging the inclination angles of mixing vanes to the coordinate directions. Axial development of mean and turbulent velocities in the subchannels were measured by the 2-color LDV system. Eddy diffusivity heat flux model and $k-varepsilon$ model were employed to analyze the turbulent heat and fluid flows in the subchannel. The turbulence generated by split mixing vanes has small length scales so that they maintain only about $10 D_H$ after the spacer grid. On the other hand, the turbulences generated by the large scale vortex continue more and remain up to $25 D_H$after the spacer gird.

  • PDF