• 제목/요약/키워드: small-scale H

검색결과 424건 처리시간 0.029초

A small-scale membrane electro-dialyser for domestic use

  • Chaalal, Omar;Hossain, Md.M.
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.43-52
    • /
    • 2015
  • A small-scale electro-dialysis system was constructed for domestic use. It is composed of six compartments in which five special polystyrene ionic membranes are housed. A series of experiments on the transport of sodium and chloride ions through polystyrene membranes was performed and the effects of electric current and voltage on the pH of water were investigated. This electrodialyser could reduce the NaCl content to an acceptable level (5307 mg/L) when water containing 9945 mg/L of sodium chloride is fed to the electrodialyser. The reduction was by the action of direct current 60 mA/100 mA when a 15 V / 20 V potential is maintained across the membrane. The results showed that the pH of the treated water attained a value in the range of 7-8, with the chloride concentration of 5307 mg/L when the voltage was in the range of 20 volts. This was achieved when two of the small-scale electro-dialysers were placed in series and the solutions from the respective compartments were mixed. This is considered useful because this complies to the requirement of drinking water standard both in terms of chloride and pH. Therefore, this type electrodialyserhas the potential for domestic uses in isolated houses where potable water supply is not available.

소규모 네트워크의 통합보안관제를 위한 SnSA 설계 및 구현 (SnSA Design and Embodiment for ESM of Small Scale Network)

  • 이동휘;신영준;김귀남
    • 융합보안논문지
    • /
    • 제3권2호
    • /
    • pp.85-97
    • /
    • 2003
  • 지난 2003년 1월 25일 오후 국내 최상위 DNS(도메인 네임 시스템)서버가 다운되면서 유.무선 인터넷 서비스가 일제히 마비되는 사상 초유의 사태가 벌어지고 전국 곳곳에서 크고 작은 혼란과 피해를 빚었다. 원인은 여러 가지의 형태로 분석되었지만 가장 큰 이유는 보안 불감증에서 기인했다고 할 수 있다. 특히 소규모 네트워크에서 보안관리자는 거의 없고 정보보호를 위한 물리적인 장치가 전무한 상태였다. 대부분의 보안시스템이 경제성을 이유로 대규모 네트워크에 중점적으로 개발되고 있으며 실시간으로 네트워크의 보안상태를 점검해 주는 보안관제센터들도 IDC나 대규모 네트워크를 중점으로 서비스 되는 실정이다. 본 논문에서는 제기되어온 문제점을 해결하기 위하여 소규모 네트워크 전용 SnSA를 설계하여 경제적인 보안관제 서비스를 연구하였다. 첫 번째로 소규모 네트워크에서 보다 많은 정보를 수집하기 위해서 네트워크 침입탐지기능 N_SnSA와 호스트 침입탐지기능 H_SnSA를 구현하였고 두 번째로 경기대학교 통합보안관제센터와 같은 공익성을 가진 센터에서 저렴한 비용으로 연동시켜 기존의 취약성을 해결하는 방법을 연구하였다.

  • PDF

원형 충돌 제트에서의 유동 및 온도 특성 (Flow and Temperature Characteristics in a Circular Impinging Jet)

  • 김정우;최해천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.237-240
    • /
    • 2002
  • In the present study, we perform LES of turbulent flow and temperature fields in a circular impinging jet at Re=5000 for two cases of H/D=2 and 6 (H denotes the distance between the jet exit and flat plate, and D does the diameter of the jet exit). In the case of H/D=2, the regular vortical structures observed in free jet do not exist because of the smaller distance than the potential core. The Nusselt number on the wall is largest at $r/D{\cong}10.67$ where vortex rings Impinge. At $r/D{\cong}1.5{\~}2.0$, the vortex rings induce the secondary vortices, resulting in a secondary peak in the Nusselt number there. In the case of H/D=6, the vortex rings change into three-dimensional vortical structures and the small-scale vortices impinge on the flat plate. The increase of turbulent intensity due to small-scale vortices results in the largest Nusselt number at the stagnation point.

  • PDF

무한궤도 수차의 성능시험 (Performance Test of a Catapillar Track-Hydroturbine)

  • 이현구;김현진;김현수
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.237-243
    • /
    • 1996
  • Current low head and small scale hydroturbines have limitations in the minimum required head and flow rate for efficient operation. This study attempts to develop a new concept hydroturbine which is expected to run efficiently even in very low head and small flow rate, so that the limitations on the conventional small scale hydropower could be alleviated and competition with other alternative energy sources in the economic respect could be attained. A small scale catapillar track- hydroturbine was fabricated and the performance test was carried out in a water tunnel over the head range of H = 0.8 m ~ 1.26 m. The peak turbine efficiency was 41.3% at the speed ratio of 0.6, and the turbine loss was mostly due to the friction at the chain drive used for power transmission from the runner to the shafts. This type of turbine is expected to become competitive when some improvement in the power transmission mechanism is made.

기존 소형버너용 압력-선회노즐의 분무특성 (Spray Characteristic of Pressure-Swirl Nozzles Used in Small Scale Burner)

  • 이동화;왕문무;노수영
    • 한국분무공학회지
    • /
    • 제8권3호
    • /
    • pp.27-32
    • /
    • 2003
  • It is important to improve the efficiency of the existing small scale burner which used in agricultural product dry system and gardening dry system. In order to economize fuel Consumption and decrease the exhaust emission especially $CO_2$, the better design for the small scale burner is needed. Spray characteristics are the essential element for the design. Macroscopic spray characteristics such as spray angle and breakup length were measured. SMD which is contained the Microscopic spray characteristics was measured too. SMD was measured at 8mm, I2mm, I6mm downstream of the nozzle tip for both Hago and Danfoss nozzles by the Malvern Particle Sizer.

  • PDF

Cosmological Tests using Redshift Space Clustering in BOSS DR11

  • Song, Yong-Seon;Sabiu, Cristiano G.;Okumura, Teppei;Oh, Minji;Linder, Eric V.
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.43.3-44
    • /
    • 2015
  • We analyze the clustering of large scale structure in the Universe in a model independent method, accounting for anisotropic effects along and transverse to the line of sight. A large sample of 690,000 galaxies from The Baryon Oscillation Spectroscopy Survey Data Release 11 are used to determine the Hubble expansion H, angular distance D_A, and growth rate GT at an effective redshift of z=0.57. After careful bias and convergence studies of the effects from small scale clustering, we find that cutting transverse separations below 40 Mpc/h delivers robust results while smaller scale data leads to a bias due to unmodelled nonlinear and velocity effects. The converged results are in agreement with concordance LCDM cosmology, general relativity, and minimal neutrino mass, all within the $68{\backslash}%$ confidence level. We also present results separately for the northern and southern hemisphere sky, finding a slight tension in the growth rate -- potentially a signature of anisotropic stress, or just covariance with small scale velocities -- but within $68{\backslash}%$ CL.

  • PDF

소규모 염색공장 폐수의 처리에 관한 연구 (A Study on the Treatment of Wastewater from Small-scale dyehouse)

  • 이준현;허항록;김광진;김민영;신재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF

High-Temperature Corrosion of T92 Steel in N2/H2O/H2S-Mixed Gas

  • Shi, Yuke;Kim, Min Jung;Park, Soon Yong;Abro, M. Ali;Yadav, Poonam;Lee, Dong Bok
    • Corrosion Science and Technology
    • /
    • 제15권3호
    • /
    • pp.125-128
    • /
    • 2016
  • The ASTM T92 steel was corroded at $600^{\circ}C$ and $800^{\circ}C$ at 1 atm of $N_2/3.1%H_2O/2.42%H_2S-mixed$ gas. The formed scales were thick and fragile. They consisted primarily of the outer FeS scale and the inner (FeS, $FeCr_2S_4$)-mixed scale containing a small amount of the $Cr_2O_3$ scale. This indicated that corrosion occurred mainly via sulfidation rather than oxidation due to the $H_2S$ gas. Since FeS was present throughout the whole scale, T92 steel was non-protective, displaying high corrosion rates.

Enhancement of Turbulent Heat Transfer of the Cooling System in Nuclear Reactor by Large Scale Vortex Generation

  • Chun, Kun-Ho;Park, Jong-Seok;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.77-84
    • /
    • 2001
  • Experimental and computational studies were carried out to investigate the turbulent heat transfer enhancement of the cooling system in nuclear reactor by large scale vortex generation. The large scale vortex motion was generated by rearranging the inclination angels of mixing vanes to the coordinate direction. Axial development of mean and turbulent velocities in the subchannels were measured by the 2-color LDV system. Eddy diffusivity concept based on $\kappa{-}\varepsilon$ model was employed to calculate the turbulent heat and momentum transfers in the subchannel. The turbulences generated by split mixing vanes has small length scales so that they maintain only about $10D_H$ after the spacer grid. On the other hand, the turbulences generated by the large scale vortex motions continue longer and remain up to $25D_H$ after the spacer grid.

  • PDF

원자로 연료봉내 대형 와유동에 의한 원자로 냉각제 시스템의 난류 증진 (Turbulent Enhancement of the Cooling System of Nuclear Reactor by Large Scale Vortex Generation in a Nuclear Fuel Bundles)

  • 전건호;박종석;최영돈
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.1004-1011
    • /
    • 2000
  • Experimental and computational studies were carried out to confirm the turbulent enhancement of the cooling system of nuclear reactor by large scale vortex generation in nuclear fuel bundle. The large scale vortex motions were generated by rearranging the inclination angles of mixing vanes to the coordinate directions. Axial development of mean and turbulent velocities in the subchannels were measured by the 2-color LDV system. Eddy diffusivity heat flux model and $k-varepsilon$ model were employed to analyze the turbulent heat and fluid flows in the subchannel. The turbulence generated by split mixing vanes has small length scales so that they maintain only about $10 D_H$ after the spacer grid. On the other hand, the turbulences generated by the large scale vortex continue more and remain up to $25 D_H$after the spacer gird.

  • PDF