• Title/Summary/Keyword: small screen

Search Result 410, Processing Time 0.026 seconds

Abnormal Changes in Groundwater Monitoring Data Due to Small-Magnitude Earthquakes (지하수 모니터링 이상변동 자료를 이용한 소규모 지진 영향 유추)

  • Woo, Nam C.;Piao, Jize;Lee, Jae-Min;Lee, Chan-Jin;Kang, In-Oak;Choi, Doo-Houng
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.21-33
    • /
    • 2015
  • This study tests the potential of detecting small-magnitude earthquakes (~M3.0) and their precursors using a long-term groundwater-monitoring database. In groundwater records from April to June 2012, abnormal changes in water level, temperature, and electrical conductivity were identified in the bedrock monitoring wells of the Gimcheon-Jijwa, Gangjin-Seongjeon, and Gongju-Jeongan stations. These anomalies could be attributed to the M3.1 earthquake that occurred in the Youngdeok area on May 30th, although no linear relationship was found between the scale of changes and the distance between each monitoring station and the epicenter, which is attributed in part to the wide screen design of the monitoring wells. Groundwater monitoring networks designed specifically for monitoring earthquake impacts could provide better information on the safety of underground space and on the security of emergency water-resources in earthquake disaster areas.

A Practical Quality Model for Evaluation of Mobile Services Based on Mobile Internet Device (모바일 인터넷 장비에 기반한 모바일 서비스 평가를 위한 실용적인 품질모델)

  • Oh, Sang-Hun;La, Hyun-Jung;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.5
    • /
    • pp.341-353
    • /
    • 2010
  • Mobile Internet Device (MID) allows users to flexibly use various forms of wireless internet such as Wi-Fi, GSM, CDMA, and 3G. Using such Internet, MID users can utilize application services. MID usage is expected to grow due to the benefits of portability, Internet accessibility, and other convenience. However, it has resource constraints such as limited CPU power, small memory size, limited battery life, and small screen size. Consequently, MIDs are not capable to hold large-sized complex applications and to process a large amount of data in memory. An effective solution to remedy these limitations is to develop cloud services for the required application functionality, to deploy them on the server side, and to let MID users access the services through internet. A major concern on running cloud services for MIDs is the potential problems with low Quality of Service (QoS) due to the characteristics of MIDs. Even measuring the QoS of such services is more technically challenging than conventional quality measurements. In this paper, we first identify the characteristics of MIDs and cloud services for MIDs. Based on these observations, we derive a number of quality attributes and their metrics for measuring QoS of mobile services. A case study of applying the proposed quality model is presented to show its effectiveness and applicability.

Establishment of High Throughput Screening System Using Human Umbilical Cord-derived Mesenchymal Stem Cells

  • Park, Eu-Gene;Cho, Tae-Jun;Oh, Keun-Hee;Kwon, Soon-Keun;Lee, Dong-Sup;Park, Seung-Bum;Cho, Jae-Jin
    • International Journal of Oral Biology
    • /
    • v.37 no.2
    • /
    • pp.43-50
    • /
    • 2012
  • The use of high throughput screening (HTS) in drug development is principally for the selection new drug candidates or screening of chemical toxicants. This system minimizes the experimental environment and allows for the screening of candidates at the same time. Umbilical cord-derived stem cells have some of the characteristics of fetal stem cell and have several advantages such as the ease with which they can be obtained and lack of ethical issues. To establish a HTS system, optimized conditions that mimic typical cell culture conditions in a minimal space such as 96 well plates are needed for stem cell growth. We have thus established a novel HTS system using human umbilical cord derived-mesenchymal stem cells (hUC-MSCs). To determine the optimal cell number, hUC-MSCs were serially diluted and seeded at 750, 500, 200 and 100 cells per well on 96 well plates. The maintenance efficiencies of these dilutions were compared for 3, 7, 9, and 14 days. The fetal bovine serum (FBS) concentration (20, 10, 5 and 1%) and the cell numbers (750, 500 and 200 cells/well) were compared for 3, 5 and 7 days. In addition, we evaluated the optimal conditions for cell cycle block. These four independent optimization experiments were conducted using an MTT assay. In the results, the optimal conditions for a HTS system using hUC-MSCs were determined to be 300 cell/well cultured for 8 days with 1 or 5% FBS. In addition, we demonstrated that the optimal conditions for a cell cycle block in this culture system are 48 hours in the absence of FBS. In addition, we selected four types of novel small molecule candidates using our HTS system which demonstrates the feasibility if using hUC-MSCs for this type of screen. Moreover, the four candidate compounds can be tested for stem cell research application.

A study on Design and Operational Factors of Rice Whitening Systems Consisting of Abrasive and Frictional whiteners -Design Criteria of Aerated-Abrasive Whitener- (조합식(組合式) 정백(精白)시스템의 설계(設計) 및 작동인자(作動因子)에 관(關)한 연구(硏究)(I) -분풍(噴風) 연삭식(硏削式) 정미기(精米機)의 설계기준(設計基準) 설정(設定)-)

  • Lee, J.W.;Noh, S.H.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.1
    • /
    • pp.20-30
    • /
    • 1987
  • Major rice grain losses both in quality and in quantity are incurred in the whitening process which is indispensable in the milling process. Rice whitening it performed by two different whitening actions known as abrasive and frictional. In Korea, abrasive-type whiteners equipped with a emery-stone roller have been adopted in the whitening system in large scale milling plants, but not in customary small scale. However, researches on this type whitener have rarely been conducted in Korea. This study was attempted to establish design criteria or a modified abrasive-type whitener which is aerated with blower. The factors considered in this study were three levels of feedscrew pitch (20, 27, 34 mm) and three levels of clearance(11, 13, 15 mm) between surfaces or emery-stone roller and screen and two levels of moisture content (14.5%, 15.7%, w.b.) of brown rice. Also, the effect of aeration on whitening performance was examined, and a system performance consisting of one pass in the aerated abrasive-type and two passes in the existing friction type was compared with the performance of the existing whitening system consisting of three passes in friction type only. The latter system is prevailed in customery small milling plants. The results of this study are summarized as follows. 1. The interactions between feed-screw pitch and chamber clearance of the aerated abrasive-type whitener had great effect on the performance of the machine. When the value of a nondimensional parameter, $C^2/(P{\cdot}d_p)$, expressing the relations between feed-screw pitch, P, and chamber clearance, C, ranged from 0.40 to 0.45, the performance of the aerated abrasive-type whitener was the best. 2. Aeration to the abrasive-type whitener gave positive effect on milled and head rice recoveries. 3. The whitening system involving the aerated abrasive-type whitener, which has appropriate feed-screw pitch and chamber clearance as described in item 1 above, produced more milled and head rice recoveries by about 1.5% and 2.0%, respectively, than the existing frictional whitening system. The former also consumed less electricity by about 10% (0.9KwH/1000kg).

  • PDF

Genetic Screening of the Canine Transcription Factor AP-2 Beta(TFAP2B) Gene in Dogs with Patent Ductus Arteriosus(PDA) (동맥관 개존증(PDA)에 이환된 개에서의 전사 인자 AP-2 beta(TFAP2B) 유전자 스크리닝)

  • Nam, So-Jeong;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.123-129
    • /
    • 2009
  • Patent ductus arteriosus(PDA) is an abnormal shunt between the descending aorta and pulmonary artery through the incompletely closed ductus arteriosus and is the most common congenital heart defect in dogs. Recent human genetic studies found that a the gene mutation in transcription factor AP-2 beta(TFAP2B) was responsible for syndromic cases of PDA. Mutations in the TFAP2B gene are associated with certain congenital cardiac defects in humans that include PDA. In this study, we isolated the entire coding exons of canine TFAP2B gene for genetic screening in dogs with PDA. Analysis of the deduced amino acid sequence suggested that the canine TFAP2B are phylogenetically closer to the human TFAP2B(100% identity in amino acid sequence) than mouse and rat. In cTFAP2B gene screening, one single c.936+203G>A base change was found in affected Maltese dogs with PDA. However, further screening found the same base change in one unaffected control dog, suggesting this base change might be polymorphism. No other base changes were found in other dog breeds enrolled in this study. Because the base change was located in the intronic region and found in an unaffected control dog, TFAP2B might not be responsible for familial PDA in Malteses and sporadic cases of other dog breeds, although the gene promoter region should be investigated before reaching to this conclusion. A future study that may take this study further would be to collect more samples and to screen TFAP2B in various breeds of dogs with PDA and other various congenital heart defects.

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

Injury of Full Seed Stage Soybeans by The Bean Bug, Riptortus pedestris (콩 종실비대성기에 톱다리개미허리노린재 가해에 의한 피해 해석)

  • Jung, Jin-Kyo;Seo, Bo-Yoon;Youn, Jong-Tag;Park, Jong-Ho;Cho, Jum-Rae
    • Korean journal of applied entomology
    • /
    • v.49 no.4
    • /
    • pp.357-362
    • /
    • 2010
  • Soybean seed injury was analyzed in the experiments in which the bean bug, Riptortus pedestris(Hemiptera: Alydidae), was released into screen-caged pots containing full seed stage(R6) of soybean. When the different stages of insects, from the 3rd instar nymphs to adults, were released into pots during 8 days in soybean R6 stage, soybean seeds with injury marks (B-type seeds) increased. The weight reduction ratio in B-type seeds was highest in the injury by the 5th instar nymphs, while the daily-produced number ratio of B-type seeds was small in the treatment. In the injury by the different number of adult released into pots, 4, 8, 16 adults caused a significant increase of B-type seeds, while 16 adults caused the significant increase of the deformed (C-type) seeds. In the injury by the different release period of adults, the total number of pods was not significantly different among treatments, while the total seed number harvested was significantly small in the release for 48 days. The release for 8 and 16 days caused a significant increase of B-type seeds, while the release for 48 days caused the increase of C-type seeds. The results indicated that injury of soybean R6 stage by the bean bug produced soybean seeds with distinct injury marks at relatively low density and during short term attack period, while it produced deformed seeds at high density and during long attack period.

Implementation of Prosumer Management System for Small MicroGrid (소규모 마이크로그리드에서 프로슈머관리시스템의 구현)

  • Lim, Su-Youn;Lee, Tae-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.590-596
    • /
    • 2020
  • In the island areas where system connection with the commercial power grid is difficult, it is quite important to find a method to efficiently manage energy produced with independent microgrids. In this paper, a prosumer management system for P2P power transaction was realized through the testing the power meter and the response rate of the collected data for the power produced in the small-scale microgrids in which hybrid models of solar power and wind power were implemented. The power network of the microgrid prosumer was composed of mesh structure and the P2P power transaction was tested through the power meter and DC power transmitter in the off-grid sites which were independently constructed in three places. The measurement values of the power meter showed significant results of voltage (average): 380V + 0.9V, current (average): + 0.01A, power: 1000W (-1W) with an error range within ±1%. Stabilization of the server was also confirmed with the response rate of 0.32 sec. for the main screen, 2.61 sec. for the cumulative power generation, and 0.11 sec for the power transaction through the transmission of 50 data in real time. Therefore, the proposed system was validated as a P2P power transaction system that can be used as an independent network without transmitted by Korea Electric Power Corporation (KEPCO).

Screening Methods for Resistant Cucumber Cultivars against Cucumber Scab Caused by Cladosporium cucumerinum Using Cucumber Fruits and Seedlings (오이 유묘와 과실을 활용한 검은별무늬병에 대한 저항성 품종 검정 방법)

  • Park, So-Hyang;Hong, Sung-Jun;Shim, Chang-Ki;Kim, Min-Jeong;Park, Jong-Ho;Han, Eun-Jung;Park, Jong-Won;Jee, Hyeong-Jin;Kim, Seok-Cheol;Kim, Yong-Ki
    • Research in Plant Disease
    • /
    • v.22 no.1
    • /
    • pp.18-24
    • /
    • 2016
  • This study was conducted to elucidate the cultural and pathogenic characteristics of Cladosporium cucumerinum PT1 and resistance of 81 commercial cucumbers (Cucumis sativus). Cucumber leaves and fruits appeared as scab were collected from a plastic film house located in Pyeongtaek, Gyeonggi-province, Korea in late March, 2015. A casual fungus was isolated from the diseased fruits on potato dextrose agar and it was identified as C. cucumerinum PT1 based on the morphological characteristics. To find out the effect of wounding and fruit size on the development of cucumber scab, small (<10 cm long), medium (10 to 20 cm long), and large (>20 cm long, commercially mature fruit) size cucumber fruits were harvested, C. cucumerinum PT1 pathogens were inoculated with a single droplet of suspension ($1{\times}10^5$ spores/ml) on wounded or unwounded cucumber fruits. Small fruits were completely damaged with showing severe water-soaking symptoms and fast pathogen growth regardless of wounded or unwounded. Meanwhile slight water-soaking symptoms on medium and large size fruits occurred and disease development into plant tissues was observed only on wounded fruits. Disease resistance of 81 commercial cucumber cultivars was evaluated on third-stage seedlings and small fruits by inoculating suspension ($1{\times}10^5$ spores/ml) of C. cucumerinum PT1. As a result, mini and pickling cultivar groups were resistant, 'Cheoeumcheoreom' cultivar was symptomless and the other cultivars were resistant to medium resistant. On the other hand, most of cucumber cultivars belonging to the other groups were susceptible. Disease resistance of cucumber against cucumber scab was significantly different among cultivars and a few cucumber cultivars showed different disease resistant responses to two bioassay methods using seedlings and small fruits. Therefore, to screen scab resistance in cucumber, a test using both fruits and seedlings is advisable. We think that the selected resistant cultivars can be used to control cucumber scab effectively under the farmhouse condition.

Study on the Effects of Hammer's Thickness and Width on the Grinding Performance of Hammer Mill (햄머밀의 햄머두께 및 폭(幅)이 분쇄성능(粉碎性能)에 미치는 영향(影響))

  • Kim, Soung Rai;Chang, Dong Il;Kwon, Soon Goo
    • Korean Journal of Agricultural Science
    • /
    • v.12 no.1
    • /
    • pp.101-107
    • /
    • 1985
  • Since most farmers breeding livestocks in Korea is depended on imported feeds, the rate of self-supplying feeds is very important for a stable development of farmers. Therefore, it is considered necessary to increase the rate of self-supplying feeds. In this study, performance tests were carried out with barley and forage to find the design's parameters of hammer for a small size hammer mill which can be driven by 3.7-7.5 kW power tiller being used by most farmers. The revolution speed of hammer mill was 3000 rpm, widths of hammer were 20mm, 30mm, 40mm, and the levels of thickness of hammer were 2mm, 4mm and 6mm. Experimental materials used were barley and forage and screen openings for barley was 4.76mm, and 3.18mm for forage. The study results can be summarized as follows; 1. Results of grinding tests showed that particle sizes were 478-774 microns for barley and 350-434 microns for forage. They were decreased according to the increasing thickness and width of hammer. 2. Fineness modulus of grinded materials were 3.07-3.62 for barley and 2.69-2.93 for forage. They were inversely proportional to thickness and width of hammer. 3. The required power for grinding was 3.8-5.0 kW for barley and 0.9-1.4 kW for forage. The thickness of hammer was more important for less power requirement than width of hammer. 4. Grinding performance of a small size hammer mill was 99-170kg/kWh for barley and 11-21 kg/kWh for forage. The thickness of hammer was an important factor for grinding performance, and inversely proportional to grinding performance. For about 3.2 of fineness modulus, 4 mm thickness was the best, and an optimum width of hammer was 30mm for a small size hammer mill.

  • PDF