• Title/Summary/Keyword: small incinerator

Search Result 31, Processing Time 0.019 seconds

Development of the Small Wastes Incinerator with High Combustion Efficiency (연소효율이 우수한 소형 소각로의 개발)

  • 한돈희;하대성
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.81-85
    • /
    • 2000
  • In order to reduce emission of air pollutants from spot incineration, it is required to develope the combustion chamber of small wastes incinerator having combustion efficiency. The characteristics of combustion of the incinerator with combustion chamber having tangential angels with surface of 45$^{\circ}$of air supply nozzles were studied in accordance with non-grate, fixed-grate and shaking-grate in the combustion chamber. Combustion conditions were evaluated with combustion efficiency, emission of hazardous gases, temperatures, ignition loss of ash and so on. Combustion efficiencies were shown 73.9% for non-gate, 81.1% for fixed-grate and 89.0% for shaking-grate. Emissions of CO were revealed 6.52 ppm for non-grate, 273 ppm for fixed-grate and 224 for shaking-grate. Comprehensively evaluated, combustion conditions got better in order of shaking-grate, fixed-grate and non-grate. This study suggests that small wastes incinerator should have shaking-or fixed-grate in combustion chamber to get better combustion condition even though at expensive cost of manufacturing.

  • PDF

Analysis of the relationship between operational condition and temperature distribution in a small incinerator (소형 소각로에서 운전조건과 온도분포 사이의 관계 분석)

  • Kim, Sung-Joon;Park, Jong-Hwan;Chun, Bong-Jun
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.63-70
    • /
    • 2000
  • One aims to find out how the operation condition of secondary inlet angle effects the temperature distribution inside a small incinerator. A finite volume commercial code, PHONICS, is used to simulate the temperature field in an incinerator. The computational grid system is constructed by Multi-Block technique. The governing equations based on the curvilinear coordinates are used. Numerical experiments are done with the five variations of secondary air inlet. The temperature distribution is quantified by the statistical deviation of temperature in an incinerator. The computational analysis says that the certain angle of secondary air inlet could improve the uniformity of temperature distribution in an incinerator.

  • PDF

Analysis of the Gas Flow Field of Primary Combustion Chamber with the Conditions of Secondary Air Injection (2차 공기 주입 조건 변화에 따른 소형 소각로 내부의 유동장 분석)

  • Choi, Byung-Dae;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.9-17
    • /
    • 2002
  • This analysis is aimed to find out how the conditions of secondary air injection affects the residence time and the turbulence energy of flue gas and flow field in a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an Incinerator. The computational grid system is constructed in a cartesian coordinate system In this numerical experiment, an independent numerical variable is the conditions of secondary air injection and dependants are the residence time of flue gas and the mean value of turbulence energy in a primary combustion chamber. The flow field and the distribution of turbulence energy are analysed to evaluate the residence time of flue gas and the turbulence energy The computational results say that the tangential injection of secondary air make the residence time much longer than the radial injection and that the radial injection of secondary make turbulence much stronger than the tangential injection.

  • PDF

Combustion and Emission Characteristics of High Calorific Industrial Waste Burned in a Small-scale Incinerator (고 발열량 산업폐기물을 처리하는 소형 소각로의 소각 및 배출 특성)

  • Lee, Gyo-Woo;Lee, Sung-Jun;Kim, Byung-Hwa;Lee, Seung-Woo;Jurng, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.42-48
    • /
    • 2002
  • Experiments on burning process of the industrial wastes were performed on a nozzle-type grate in the industrial waste incinerator with a capacity of 160 kilograms per hour. The temporal variations of temperatures and concentrations of the exhaust gas were measured and analyzed. The synthetic leather waste with the moisture content less than 2% was used. The experimental results show that the CO concentration in the exhaust gas exceeds the limit, 600 ppm, and the gas temperature fluctuates too much when 8 kg of waste was supplied every 3 minutes, equivalent to the capacity of 160kg per hour. That is a typical burning mode of this high-calorific industrial waste. When the smaller unit waste input, 6kg per every 2 min 15 seconds was supplied, we could reduce the fluctuations of the furnace temperature and improve the exhaust emissions, especially the CO concentration.

  • PDF

Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator (2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향)

  • Kim S. J.;Min I. H.;Park M. H.;Park M. J.
    • Journal of computational fluids engineering
    • /
    • v.5 no.3
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF

The change of recirculation zone with the inlet angle of secondary air in an incinerator (2차 공기 주입각도에 따른 소각로 내부의 재순환 영역 변화)

  • Kim, Sung-Joon;Park, Min-Ju;Chun, Bong Jun
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.55-62
    • /
    • 2000
  • The purpose of this research is to find out how the inlet angle of secondary air affects the formation of recirculation zone inside a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an incinerator. The computational grid system is constructed by Multi-Block technique. Numerical experiments are done with the five different angles of secondary air inlet. The formation of recirculation zone is evaluated by checking velocity fields. The computational results show that recirculation zone is clearly formed from 60 degree of inlet angle and the zone of recirculation is widen as angle of recirculation is increased to $75^{\circ}$.

  • PDF

A Study on the Treatment of Incinerator Wastewater with Biofilm Reactor (접촉산화법에 의한 소각로 배출폐액의 처리에 관한 연구)

  • 신대윤;서동우
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.3
    • /
    • pp.92-97
    • /
    • 2000
  • The treatment of the washout from small scale incinerator was performed physically, chemically and biologically. The results are as follows. 1. SS, FS removal efficiency of washout wastewater from incinerator was 67.4%, 37.4%, while SS, FS of sewage wastewater was removed 63.2% 35.4% respectively. 2. The optimal conditions for chemical coagulation turned out to be pH 7.5, alum(Al2O3 10%) 30ml/ι and polyelectrolyte(A-601P 0.1%) 4ml/ι. SS 86%, FS 89.5%, BOD 42.5% and CODMn, 63.5% was removed and the removal efficiency of some metals are shown as Pb 93.5%, Zn 86.5% and Fe 80.6%. The concentration of the effluent was SS 9mg/ι, BOD 98.4mg/ι, and CODMn 138.4mg/ι. 3. The removal efficiency in treating washout wastewater of incinerator through HBC-briquet media was getting higher with increasing HRT, and mixed wastewater with 1:1, 1:2 ratio could be met up to the standard limit with higher HRT than 12hr. Under the condition of 1:2 mix ratio and HRT 24 hr, removal efficiency of SS, BOD, CODMn, T-N and T-P was 92.1%, 90%, 87%, 48.2% and 48%, respectively, and the concentration of treated wastewater was SS 2.9 mg/ι, BOD 10.3mg/ι, CODMn 14.1mg/ι, T-N 11.6 mg/ι and T-P 1.3 mg/ι, respectively.

  • PDF

A Study on the Combustion Characteristics of the Small Scale Cyclone Incinerate System for Sludge (슬러지용 소형 사이클론 소각 시스템의 연소특성에 대한 연구)

  • Park, Woo-Cheul;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The performance of the small scale cyclone incinerate system (100kg/hr) to process the sewage sludge containing high moisture is evaluated. The incinerate system design is based on properties of the domestic sewage sludge. The combustion characteristics of the incinerate system is tested and analyzed with the various operation conditions of the moisture level, the sludge feed rate and the auxiliary fuel feed rate. The pressure loss of the whole system is appeared relatively small of 700mmAq under the normal operating condition and the temperature distribution of the incinerator internal combustion is maintained less than 1000C. Auxiliary fuel of 4.7 1/hr is required to incinerate 100kg sludge which include 87% moisture. Because the inside temperature of the incinerator is maintained less than $1000^{\circ}C$, it is predicted that the most NOx measured is produced not from the heat during the combustion process but from the oxidation of the N ingredient in the sludge. From the component analysis of ash, the organic matter is not entirely detected. Accordingly, it is estimated that the complete combustion has been accomplished in the incinerator.

  • PDF

A Study on Sorbent Application of Hard-Shelled Mussel Waste Shell on the Medium/small Scale Waste Incinerator and Flue Gas Desulfurization Process (중.소형 폐기물소각로 및 배연탈황공정용 홍합(Hard-Shelled Mussel) 패각페기물 Sorbent 적용에 관한 연구)

  • 정종현
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • The objective of this study is to investigate the waste recycling possibility, practicability, economic efficiency and acid gas sorbent use of the hard-shelled mussel. This study is to investigate the hydration/calcination reaction and fixed bed reactor. The physical-chemical characteristics of the hard-shelled mussel were analyzed by ICP SEM-EDX, BET and pore volume. Thus, the results could be summarized as follows; Hard-shelled mussel can be used as iron-manufacture and chemical sorbents considering more than 53.7% of the mussel is lime content. The SO$_2$removal efficiency of the hard-shelled mussel after calcined hydration increased thirty times as a result of the higher pore size, specific surface area and pore volume. Also, the CaO content, pore volume, pore size distribution and specific surface area greatly influenced the SO$_2$ and NOx removal reactivity. The optimum particle diameter average of hard-shelled mussel was $\pm$100 mesh, which was applied to the sorbent on the medium/small scale waste incinerator and flue gas desulfurization processes.

Source Estimation of Dioxin in Soil Using a Congener Pattern (이성체 정보를 이용한 토양 중 다이옥신 오염원 해석)

  • Kim, Jong-Guk;Kim, Kyoung-Soo;Kim, Jae-Sik;Shin, Sun-Kyoung;Chung, Young-Hee;Chung, Il-Rok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.316-322
    • /
    • 2005
  • In this study, the concentration of 17 dioxin congeners in the soil samples near a waste incinerator with respect to distance from incinerator and wind directions were investigated. The effect of PCB source was investigated using the cluster analysis method. The total concentration and I-TEQ concentration of dioxin ranged from 31.065 to 7,257.499 pg/g(dry weight) and from 0.099 to 35.191 pg I-TEQ/g(dry weight.), respectively. There was a weak correlation(not statistically significant) observed between soil concentration and wind direction, and the distance from the incinerator. The reason may be due to the presence of the local combustion sources other than the target incinerator. The fraction of PCDFs and PCDDs was also examined to study the effect of incinerator. The fraction of PCDFs was decreased with the distance from the incinerator. The influence of target incinerator was found within a 500-meter radius. The high concentration in the for site was due to small incinerators and the use of agricultural chemicals such as PCP. To investigate the relationship between soil near the incinerator and the sources, the cluster analysis was conducted using the congener pattern. As a result soil samples were divided into four groups and were qualitatively estimated the influence of sources such as incinerator and PCP by comparing the congener pattern of each roups. It was thought that a cluster analysis was a useful statistical method for the source estimation of dioxin.