• Title/Summary/Keyword: small chamber method

Search Result 158, Processing Time 0.026 seconds

Assessment of VOCs Emission Characteristics from Building Materials such as Wall Paper, Paints, and Adhesives Using Small Chamber Method (소형챔버법을 이용한 건축자재 중 벽지, 페인트 및 접착제의 VOCs 방출특성 평가)

  • Lee Suk-Jo;Jang Seong-Ki;Cho Yong-Sung;Jung Kyung- Mi;Jeong Gi-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.191-204
    • /
    • 2005
  • Building and furnishing materials and consumer product are important sources of volatile organic compounds(VOCs) and other aldehydes in the indoor environment. Some available evidence indicates that VOCs can cause adverse health effects to the building occupants and contribute to some of the symptoms of what we call, 'Sick House Syndrome' in Korea. The aims of this study were to evaluate the efficiency of emission system and to investigate comparison of the emission characteristics of different building materials such as wall-papers, paints, and adhesives. The emission of VOCs from building materials were determined in the small chambers defining the temperature, relative humidity, and ventilation rate in this study. VOCs were sampled for 20 minutes using Tenax-TA tubes and analysed by GC-MS with thermal desorption. The stability of conditions for temperature and relative humidity in this small chamber system showed that the fluctuation of temperature was between 25.4$\pm$0.3$^{\circ}C$ and that of relative humidity was 50.2$\pm$0.6$\%$ under the airflow rate of 167 mL/min. The emission tests from building materials resulted in TVOC emission rates of 0.011 $\~$ 3.108 mg/m$^{2}$h after 7 days. The general wall-papers emitted toluene abundantly and the natural wall-papers mainly emitted n-butanol and a minor amount of alkanes compound such as n -tetradecane. The remainder consisted of toluene, m,p -xylene, and styrene. The paints mainly emitted toluene and the adhesives mainly emitted chloroform as well as toluene. As a result, this study is expected to suggest meaningful data for future studies in exposure control through selecting healthy building materials and for the establishment of guidelines for various building materials in Korea.

The Fundamental Study on Liquid Phase LPG Injection System for Heavy-Duty Engine (II) (대형엔진용 액상분사식 LPG 연료공급방식에 대한 기초연구 (2))

  • 김창업;오승묵;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.1-7
    • /
    • 2001
  • Recently, several LPG engines for heavy-duty vehicles have been developed, which can replace some diesel engines that are one of a main source for air pollution in urban area. As a preliminary study on the liquid phase LPG injection (hereafter LPLI) system applicable to a heavy duty LPG engine, the engine output and combustion performance were investigated with various combustion chambers and fuel compositions using a single cylinder engine equipped. Experimental results revealed that ellipse, double ellipse and nebula type combustion chamber made a more advantage in breaking swirl flow into small turbulence scale than bathtub type. Especially, performance of nebula type showed most highest efficiency and engine output under lean mixture conditions. An investigation fur various LPG fuel compositions was also carried out, and revealed that the case with 40% propane and 60% butane shows the lowest efficiency at stoichiometry, however, as the mixture became leaner its efficiency increased and became even higher for 100% propane case.

  • PDF

Retention of Endothelial Cells adhered on Polyurethane Surface under Flow Condition

  • Chang, Jun-Keun;Chang, Hyun-A;Kim, Jin-Hee;Kim, Jong-Won;Han, Dong-Chul;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.355-364
    • /
    • 1996
  • Construction of the stable monolayer of endothelial cells onto physicochemically modified polymeric surFace is one of the appropriate method to develop the small caliber vascular graft with the long-term patency. In this study, we constructed the monolayer of endothelial cells on the fibronectin rind the extracellular matrix-coated polyurethane surface derived from human fibroblast cells. To elucidate the adhesion strength of endothelial cells on the extracellular matrix-coated polyurethane, a laminar flow chamber apparatus was developed to exposure the shear stress on the apical membrane of ondothelial cells. Endothelial cells show the strongest adhesion after two days of seeding onto the fibronectin-coated polyurethane surface, whereas endothelial cells on the extracellular matrix derived from the human flbroblast cells show the minimal doubling time of cellular growth.

  • PDF

A Study on the Flow Control for Stable Combustion of Liquid Rocket (액체로켓의 연소안정을 위한 유량공급에 관한 실험적 연구)

  • Park, Hee-Ho;Kim, Yoo;Cho, Nam-Choon;Keum, Young-Tag
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.788-794
    • /
    • 2002
  • In liquid rocket engine, propellant feed rate is proportional to approximately square root of the pressure difference between injector head and combustion chamber. This ΔP depends on the engine design, but in general on the order of 50psi. However, during ignition period, especially for the pressurized feed system, combustion chamber pressure is almost atmospheric and large ΔP causes over flow of propellants which may lead to catastrophic accident due to hard start. Hard start may be prevented by applying cavitating venturi or/and two step ignition. In cavitating venturi, evaporated propellants near the venturi throat become chocked and flow rate depends on only upstream condition. In two step ignition propellants are supplied to the liquid engine in two different flow rate. First step, to avoid hard start, small amount of propellants are supplied to build up chamber pressure in safe zone, then full propellants to ensure design pressure. In this study, both cavitating venturi and two step ignition method were used for the hot test and hard start problem was completely solved.

A Study on the Characteristics of Soot Formation and Oxidation in Free Fuel Droplet Array

  • Lee, Myung-Jun;Kim, Jong-Youl;Yeom, Jeong-Kuk;Ha, Jong-Yul;Chung, Sung-Sik
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.851-860
    • /
    • 2002
  • In this study, it was attempted to obtain the fundamental data for the formation and oxidation of soot from a diesel engine. Combustion of spray injected into a cylinder is complex phenomenon having physical and chemical processes, and these processes affect each other. There are many factors in the mechanism of the formation and oxidization of soot and it is necessary to observe spray combustion microscopically. In order to observe with that view, free fuel droplet array was used as an experimental object and the droplet array was injected into an atmospheric combustion chamber with high temperature. Ambient temperature of the combustion chamber, interdroplet spacing, and droplet diameter were selected as parameters, which affect the formation and oxidation of soot. In this study, it was found that the parameters also affect ignition delay of droplet. The ambient temperature especially affected the ignition delay of droplet as well as the flame temperature after self-ignition. As the interdroplet spacing that means the local equivalence ratio in a combustion chamber was narrow, formation of soot was increased. As diameter of droplet was large, surface area of the droplet was also broad, and hence evaporation of the droplet was more active than that of a droplet with relative small diameter.

A Low-Cost Method to Evaluate Absorber Reflectivity Using an Antenna with a Small Radiating Aperture and Frequency-Domain Instrument

  • Oh, Soon-Soo;Lee, Young Hwan
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.1148-1151
    • /
    • 2013
  • We propose a way to measure the absorber reflectivity at a low cost. Only one simple antenna with a small radiating aperture and a frequency-domain instrument are utilized. The previously used equation for calculating the reflectivity of an absorber is inaccurate, and, therefore, a new equation is derived based on multiple reflection analysis and three test models. Notably, the reflection coefficient of the antenna is included in the derived equation. The accuracy of the proposed method is proven through simulation and measurements. It can be easily applied to a product examination by absorber manufacturers and customers owing to its advantages of simplicity, cost effectiveness, and non-cutting examination.

Performance Improvement of Cross-Flow type Small Hydro Turbine by Air Layer Effect (소수력발전용 횡류수차의 공기층효과에 의한 성능향상)

  • Choi, Young-Do;An, Young-Joon;Shin, Byeong-Rog;Lee, Dong-Yeup;Lee, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1070_1071
    • /
    • 2009
  • Recently, small hydropower attracts attention because of its clean, renewable and abundant energy resources to develop. Therefore, a cross-flow hydraulic turbine is proposed for small hydropower development in this study. The turbine‘s simple structure and high possibility of applying to the sites of relatively low effective head and large flow rate can be advantages for the introduction of the small hydropower development. The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. CFD analysis for the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively. The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss in the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

  • PDF

Dynamic Characteristics of Pintle Nozzle about Changes of Chamber Boundary Condition (연소실 경계조건 변화에 따른 핀틀 노즐의 동특성 연구)

  • Jeong, Kiyeon;Kang, Dong-Gi;Lee, Daeyeon;Choi, Jaesung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.22-31
    • /
    • 2018
  • In this study, numerical simulations were performed to determine the dynamic characteristics of a pintle nozzle, with changes to the chamber boundary conditions. To apply movement, to the pintle, the nozzle and pintle were created separately by an auto-grid generation program using an overset grid method. The chamber boundary conditions were selected between a constant mass-flow rate condition and a propellant burn-back condition. The pressure and thrust characteristics of the constant mass-flow rate condition were determined by changing the ratio of the mass-flow rate in the inlet. The propellant burn-back condition was considered by formulation of the combustion rate. The burn-back conditions represented nonlinear phenomena, unlike the constant mass flow rate, and a small flow rate resulted in a large change in the chamber pressure.

A Study on the Korean Fit Test Panel and Static Headform Chamber (한국형 테스트 패널과 Static Headform Chamber 개발연구)

  • Hyekyung Seo;Hoyeong Jang;Harim An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.145-155
    • /
    • 2023
  • Objectives: A fit test panel is needed to identify the fit performance of a respirator and its face seal. This is a criterion for selecting subjects that can represent the facial characteristics of users. Although anthropometry data has been developed for people in United States and China it is not yet present in Korea. This study aimed to develop a Korean fit test panel and test headform. Methods: For the 7th and 8th waves of the Size Korea anthropometry data, facial measurements of 11,429 people aged 15 to 69 years were used for analysis. PCA and bivariate panel were classified using the ISO16976-2:2022(E) anthropometrics analysis method. Based on this result, a static headform was developemed and a fit test chamber was constructed. Results: Of the 11,429 Korean people used for principal component analysis, 11,300 were included in the ellipse, marking an acceptance rate of 98.87% on PCA panel. The face types were classified into five types. Among them, a large, medium, and small static headform were printed using a 3D printer. In addition, 10,985 people (96.12%) were included in the bivariate panel based on face length and face width. The y-axis (face length) boundary was 97.87 to 134.59 mm, and the x-axis (face width) boundary was 120.75 to 158.23 mm. Conclusions: Compared to the ISO analysis, the Korean principal component was narrower in the width item (PC1) and longer in the length item (PC2). For the future, it is necessary to conduct a fit test using the developed headform and chamber device to confirm the usefulness of this Korean test panel. Therefore, this study is considered valuable as basic research for Korean test panels.

A Prediction Model for TVOC and HCHO Emission of Paint Materials (페인트에서 방출되는 TVOC 및 HCHO 방출량 예측모델)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • It is highly recognized that there is need for protection against indoor air pollution, as we realize environmental pollution is growing, For example, in an indoor environment, a person spends more than 80 percent of their time inside the building. Thus, concern about indoor decoration materials is growing, since they cause pollution in the rooms of an apartment, as well as in offices. As the indoor decoration materials become more diverse and lusurious, so the effect of VOCs(Volatile Organic Compounds) and HCHO(Formaldehy) is growing. The indoor decoration materials cause the Sick Building Syndrome, such as headaches, dizziness, or lack of concentraion, and they in turn cause serious deterioration in people's health. In this study, I probed the status of the indoor air pollution and carried on an investigation and analysis about the prevention technique. In doing so, I performed experimental tests and an assessment of the indoor decoration materials of an apartment. I also examined elements of the emitted and the emission. Finally, I examined the character of emissions, by changing environmental conditions, such as the temperature, humidity, and ventilation. With respect to VOCs tests, I applied the method of solid state adsorption using the adsorptive tube, based on the measurement of the American EPA TO-17, ASTM 5116-97, and the measurement of the Japanese Wall Decoration Industrial Association. The tested sample was analyzed by High Performance Liquid Chromatography, after going through the process of dissolvent extraction. As subjects of the test, Paint were selected. The process of this test is as follows; first, I figured out the character of the emission, by measuring the emitted concentration of VOCs and HOHC from the indoor decoration materials of an apartment. Second, I made a small-scale chamber and the test was processed in the chamber in order to suggest an environment-friendly prediction modlel development.