• Title/Summary/Keyword: small RNA (sRNA)

Search Result 342, Processing Time 0.017 seconds

Effect of Vinclozolin on the Onset of Puberty in Immature Female Rats (미성숙 암컷 흰쥐의 사춘기 개시에 미치는 Vinclozolin의 영향)

  • An, Na-Kyung;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.11 no.3
    • /
    • pp.245-251
    • /
    • 2007
  • Vinclozolin(VCZ), a systemic dicarboximide fungicide, has been used in the control of diseases caused by microorganism of some species in fruits, vegatables and ornamental plants. Although VCZ itself is a very weak antagonist for androgen receptor binding, both melabolites M1 and M2 are effective antagonists. The present study was undertaken to examine whether prepubertal exposure to VCZ affects on the onset of puberty and the associated reproductive parameters such as hormone receptor expressions in female rats. VCZ(10 mg/kg/day) was administered daily from postnatal day 21(PND 21) through the day when the first vaginal opening(V.O.) was observed. Gross anatomy and weight of reproductive tissues were compared to test the VCZ's effects on the cell proliferation. Furthermore, histological studies were performed to assess the structural alterations in the tissues. To determine the transcriptional changes in progesterone receptor(PR), total RNAs were extracted and applied to the semi-quantitative reverse transcription polymerase chain reaction(RT-PCR). As a result, delayed V.O. was shown in the VCZ group(PND $34.00{\pm}1.22$) compared to the control group(PND $38.20{\pm}1.92$; p<0.01). VCZ treatment significantly decreased the wet weight of ovaries and uteri compared to the control group(p<0.01). Graafian follicles and corpora lutea were observed only in the ovaries from the control animals, while numerous primary, secondary follicles and small atretic follicles were observed in the ovaries from VCZ group. Similarly, hypotrophy of luminal and glandular uterine epithelium was found in the VCZ group. In the semi-quantitative RT-PCR studies, the transcriptional activity of PR in ovary(p<0.01) from VCZ group were significantly lower than those from the control group while in uterus were similar compared with the control group. The present studies demonstrated that the acute exposure to VCZ during the critical period of prepubertal stage could inactivate the reproductive system resulting delayed puberty in female rats.

  • PDF

Analysis of Respiratory Motional Effect on the Cone-beam CT Image (Cone-beam CT 영상 획득 시 호흡에 의한 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mi-Sun
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • The cone-beam CT (CBCT) which is acquired using on-board imager (OBI) attached to a linear accelerator is widely used for the image guided radiation therapy. In this study, the effect of respiratory motion on the quality of CBCT image was evaluated. A phantom system was constructed in order to simulate respiratory motion. One part of the system is composed of a moving plate and a motor driving component which can control the motional cycle and motional range. The other part is solid water phantom containing a small cubic phantom ($2{\times}2{\times}2cm^3$) surrounded by air which simulate a small tumor volume in the lung air cavity CBCT images of the phantom were acquired in 20 different cases and compared with the image in the static status. The 20 different cases are constituted with 4 different motional ranges (0.7 cm, 1.6 cm, 2.4 cm, 3.1 cm) and 5 different motional cycles (2, 3, 4, 5, 6 sec). The difference of CT number in the coronal image was evaluated as a deformation degree of image quality. The relative average pixel intensity values as a compared CT number of static CBCT image were 71.07% at 0.7 cm motional range, 48.88% at 1.6 cm motional range, 30.60% at 2.4 cm motional range, 17.38% at 3.1 cm motional range The tumor phantom sizes which were defined as the length with different CT number compared with air were increased as the increase of motional range (2.1 cm: no motion, 2.66 cm: 0.7 cm motion, 3.06 cm: 1.6 cm motion, 3.62 cm: 2.4 cm motion, 4.04 cm: 3.1 cm motion). This study shows that respiratory motion in the region of inhomogeneous structures can degrade the image quality of CBCT and it must be considered in the process of setup error correction using CBCT images.

  • PDF