• 제목/요약/키워드: slit damper

검색결과 34건 처리시간 0.018초

Development of a seismic retrofit system made of steel frame with vertical slits

  • Kang, Hyungoo;Adane, Michael;Chun, Seungho;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • 제44권2호
    • /
    • pp.283-294
    • /
    • 2022
  • In this study, a new seismic retrofit scheme of building structures is developed by combining a steel moment frame and steel slit plates to be installed inside of an existing reinforced concrete frame. This device has the energy dissipation capability of slit dampers with slight loss of stiffness compared to the conventional steel frame reinforcement method. In order to investigate the seismic performance of the retrofit system, it was installed inside of a reinforced concrete frame and tested under cyclic loading. Finite element analysis was carried out for validation of the test results, and it was observed that the analysis and the test results match well. An analytical model was developed to apply the retrofit system to a commercial software to be used for seismic retrofit design of an example structure. The effectiveness of the retrofit scheme was investigated through nonlinear time-history response analysis (NLTHA). The cyclic loading test showed that the steel frame with slit dampers provides significant increase in strength and ductility to the bare structure. According to the analysis results of a case study building, the proposed system turned out to be effective in decreasing the seismic response of the model structure below the given target limit state.

V형 강재댐퍼의 이력특성 평가 (Evaluation on Hysteretic Behaviors of V Shaped Metallic Dampers)

  • 이현호;김세일
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.254-262
    • /
    • 2011
  • 본 연구의 목적은 슬릿형 강재댐퍼보다 에너지 소산능력 등이 우수할 것으로 예상되는 V형 강재 댐퍼 개발에 있다. 이를 위하여 댐퍼 스트럿의 높이 및 각도에 대한 실험체 9개를 만들어 전단실험을 수행하였다. 실험결과, 스트럿 높이가 270mm이고, 스트럿 각도 $60^{\circ}$인 경우의 V형 강재댐퍼가 가장 우수한 내진성능 보유한 것으로 평가되었다. 또한 기존내력식을 이용한 댐퍼의 항복강도를 비교한 결과, 기존 실험결과를 분석한 범위 내에서 V형 댐퍼의 실험결과가 높게 평가되는 것으로 나타났다.

고감쇠고무와 강재슬릿의 복합 댐퍼로 보강한 건축물의 해석적 성능평가 (Analytical Performance Evaluation of Structure Reinforced with HRS Damper)

  • 김유성;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.31-38
    • /
    • 2022
  • In this study, an incremental loading test of the HRS(Hybrid Rubber Slit) damper was additionally performed to define the physical characteristics according to the incremental test results, and an analytical study was performed according to the damping design procedure by selecting an example structure. As a result of performing seismic performance evaluation before reinforcement by selecting a RC structure similar to an actual school structure as an example structure, the story drift ratio was satisfied, but some column members collapsed due to bending deformation. In order to secure the seismic performance, the damping design procedure of the HRS damper was presented and performed. As a result of calculating the amount of damping device according to the expected damping ratio and applying it to the example structure, the hysteresis behavior was stable without decrease in strength, and the story drift ratio and the shear force were reduced according to the damping effect. Finally the column members that had collapsed before reinforcement satisfied the LS Level.

꺽쇠형 강재 댐퍼의 변위 및 속도 의존성 (Displacement and Velocity Dependence of Clamped Shape Metallic Dampers)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.62-70
    • /
    • 2013
  • 본 연구의 목적은 일자형 슬릿형 강재댐퍼보다 에너지 소산능력 등이 우수할 것으로 평가된 꺽쇠형 강재 댐퍼의 변위 및 속도의존성 평가에 있다. 이를 위하여 6개의 시험체를 대상으로 의존성 시험을 수행하였다. 시험변수는 변위의존성 및 속도의존성이다. 변위의존성 시험결과, 큰 목표변위 (50mm)의 반복횟수 및 누적에너지소산능력은 적은 목표변위 (25mm)에 비하여 감소하였다. 또한 짧은 목표변위보다 큰 항복강도 및 조기파단을 나타내었다. 속도의존성 평가에서는 빠른 목표속도(60mm/sec)의 반복횟수 및 누적에너지소산능력이 느린 목표속도 (40mm/sec)에 비하여 감소하였다. 따라서 강재댐퍼의 이력 의존성은 가력 변위 및 속도와 밀접한 연관이 있는 것으로 평가되었다.