• Title/Summary/Keyword: sliding test

Search Result 655, Processing Time 0.036 seconds

A STUDY OF THE NORMAL & ABNORMAL OCCULSAL PATERNS IN ADULTS USING THE SUPERIMPOSED RUBBER PATTERN METHOD (Superimposed Rubber Pattern법에 의한 성인 정상 및 비정상 교합자의 교합 양상에 관한 연구)

  • Choi, Dae-Gyun;Lee, Sung-Bok;Kwon, Young-Hyuk;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.467-491
    • /
    • 1995
  • In order to analyze the occlusin of intercuspation with maximun bite force, fifteen healthy adult subjects with the ages 23 to 27 were studied(Group1 ; 5-normal occlusion with Angle's Class1, Group2 ; 5-Angle's Class2 malocclusion, Group3 ; 5-Angle’s Class3 malocclusion). Head Position was fixed with occlusal plane paralleling to horizontal line and occlusal registration r cord was made with polyether rubber impression material(Ramitec, ESPECo. West Germany). After all subject were trained for maximum intercuspation at least 5 times, occlusal registration procedure was repeated for this study. Lower posterior rubber occlusal registration records were sliced with 1mm thickness using precision metal sliding channel(Hitachi Ind. Co., Japan). Gross sectional drawings were traced from occluding view of upper and lower posterior teeth on the rubber slices using digitizer, and superimposed for the determination of each drawing distance(Superimposed Rubber Pattern Method). Based on superimposed rubber pattern drawings, total area of occlusal view, sum of each area of the 5 divided occlusal contact provinces and its ratio, total area and number of occlusal contact area were determined to elucidate occlusal stability in the normal and abnormal occlusion groups. The data were analysed by t-test(p=0.05) to determine statistical significance. The obtained results were as follows : 1. Group1 showed the largest standard area with occlusal view of the lower posterior teeth and Group3 showed the smallest area. There was a significant difference between Group2 and Group3(p=0.025), and Gropu1 was not statistically different for both Group2 and Group3. 2. Means and ratio of the under 2.0mm area(D) and ratio showed $197.49mm^2$, 59.76% in Group1, $188,69mm^2$, 56.10% in Group2, and $174.23mm^2$, 55.76% in Group3. The results that Group1 has the most area/ratio and Group3 has the least area/ratio can be considered Group1 is the most advantageous for masticatory effective area, and Group3 is the least adnantageous. 3. Means and ratio of the under 1.0mm area(C) were $198.96mm^2$, 42.65% in Group1, 123.06$mm^2$, 46.58% in Group2, and $92.24mm^2$, 29.52% in Group3. These data means that Group1 is the most advantageous in terms of masticatory effective area and Group3 is the least. 4. Means and ratio of the under 0.5mm area(B) were $86.68mm^2$, 26.68% in Group1, $62.98mm^2$, 18.71% in Group2, and $36.44mm^2$, 11.66% in Group3. These can also be considered Group1 is the most advantageous for masticatory effective area and occlusal stability. 5. Means and ratio of the under 0.05mm area(A) were $30.92mm^2$, 9.21% in Group1, $14.31mm^2$, 4.25% in Group2, and $7.59mm^2$, 2.43% in Group3. The area ratio of the each subject group was(4.1) : (1.9) : (1)and the data of the under 0.05mm area has the intimate relationship with inter-group and intra-group data/ratio. 6. First molar showed the most occlusal contact points in all subject group and Group1 showed somewhat uniformly distributed occlusal contact point except first premolar. In Group2, all contact point in posterior teeth showed significantly reduced distribution except first molar. Group3 showed evenly distributed contace points in first and second molars.

  • PDF

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Relation Between Degree of Consistency of Elementary Students' Preconceptions on the Brightness of Electric Bulb and Their Cognitive Conflict (전구의 밝기에 대한 초등학생들의 사전개념 일관성 정도와 인지갈등 정도와의 관계)

  • Jung Mee-young;Kim Kung-suk;Kwon Jaesoo
    • Journal of Korean Elementary Science Education
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This study was to investigate the elementary students' preconception on the brightness of electric bulb and degree of consistency on their preconceptions. Participants were 160 students of fifth graders in Seoul area. They had already teamed about the brightness of series circuit and parallel circuit of batteries. After they solved six problems in the same context, we provided them a pair of circuit which was an anomalous situation. And then they conducted CCLT (Cognitive Conflict Level Test). Elementary school students showed various preconceptions when they explained the light of bulb of two Simple electric Circuits. Many Students Consistently Showed the Scientific misconceptions like 'the light of bulb of two simple electric circuits was that the more batteries and the fewer bulbs were brighter.' The level of consistency that students presented scientific misconceptions was grouped all of four, such as 'high, middle, low, and nothing.' Therefore the higher scientific achievement they have, the higher consistency they have. As the students had high consistency level, they revealed high cognitive conflict level significantly. This high consistency will help them to change their preconception on the brightness of electric bulb and their cognitive conflict.

  • PDF

The Tooth Size RelaTionship Between Crowding Patients and Normal Subjects in Korean (총생치열을 갖는 교정환자와 정상인의 치아크기 비교)

  • Han, Man-Deuk;Jeon, Eun-Sook
    • Journal of dental hygiene science
    • /
    • v.6 no.1
    • /
    • pp.29-34
    • /
    • 2006
  • This study was undertaken to compare the tooth and arch size between crowding patient and normal subjects. Two group of dental casts were selected on the basis of crowding patients and normal subjects. One group, consisting of 40 pair of dental casts(20 male and 20 female), exhibited noncrowded dentitions. A second group, consisting of 40 pairs of dental cast(21 male and 21 female), exhibited remarkably crowding need for orthodontic treatment. Tooth width measurements were made with a sliding digital caliper with Vernier scale neared 0.01 mm. Mean, standard deviation, T-test of the following parameters were used to compare two group : individual mesiodistal crown widths, arch width and arch length. The following result were obtained. In the mesiodistal crown widths, normal subjects had generalized larger teeth than Wheeler's results(human tooth size index), except for maxillary central incisor, maxillary 2nd premolar, mandibular canine, and mandibular 1st molar. In the orthodontic patients with crowded dentitions, the mesiodistal tooth crown widths were generalized larger teeth than noncrowded normal subjects. In the arch width and arch length, the crowded dentition group had smaller arch width and arch length than the normal group.

  • PDF

Studies on the Mechanical Properties of Weathered Granitic Soil -On the Elements of Shear Strength and Hardness- (화강암질풍화토(花崗岩質風化土)의 역학적(力學的) 성질(性質)에 관(關)한 연구(硏究) -전단강도(剪斷强度)의 영향요소(影響要素)와 견밀도(堅密度)에 대(對)하여-)

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.66 no.1
    • /
    • pp.16-36
    • /
    • 1984
  • It is very important in forestry to study the shear strength of weathered granitic soil, because the soil covers 66% of our country, and because the majority of land slides have been occured in the soil. In general, the causes of land slide can be classified both the external and internal factors. The external factors are known as vegetations, geography and climate, but internal factors are known as engineering properties originated from parent rocks and weathering. Soil engineering properties are controlled by the skeleton structure, texture, consistency, cohesion, permeability, water content, mineral components, porosity and density etc. of soils. And the effects of these internal factors on sliding down summarize as resistance, shear strength, against silding of soil mass. Shear strength basically depends upon effective stress, kinds of soils, density (void ratio), water content, the structure and arrangement of soil particles, among the properties. But these elements of shear strength work not all alone, but together. The purpose of this thesis is to clarify the characteristics of shear strength and the related elements, such as water content ($w_o$), void ratio($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$), and the interrelationship among related elements in order to decide the dominant element chiefly influencing on shear strength in natural/undisturbed state of weathered granitic soil, in addition to the characteristics of soil hardness of weathered granitic soil and root distribution of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands. For the characteristics of shear strength of weathered granitic soil and the related elements of shear strength, three sites were selected from Kwangju district. The outlines of sampling sites in the district were: average specific gravity, 2.63 ~ 2.79; average natural water content, 24.3 ~ 28.3%; average dry density, $1.31{\sim}1.43g/cm^3$, average void ratio, 0.93 ~ 1.001 ; cohesion, $ 0.2{\sim}0.75kg/cm^2$ ; angle of internal friction, $29^{\circ}{\sim}45^{\circ}$ ; soil texture, SL. The shear strength of the soil in different sites was measured by a direct shear apparatus (type B; shear box size, $62.5{\times}20mm$; ${\sigma}$, $1.434kg/cm^2$; speed, 1/100mm/min.). For the related element analyses, water content was moderated through a series of drainage experiments with 4 levels of drainage period, specific gravity was measured by KS F 308, analysis of particle size distribution, by KS F 2302 and soil samples were dried at $110{\pm}5^{\circ}C$ for more than 12 hours in dry oven. Soil hardness represents physical properties, such as particle size distribution, porosity, bulk density and water content of soil, and test of the hardness by soil hardness tester is the simplest approach and totally indicative method to grasp the mechanical properties of soil. It is important to understand the mechanical properties of soil as well as the chemical in order to realize the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to study the correlation between the soil hardness and the distribution of tree roots of Pinus rigida Mill. planted in 1966 and Pinus rigida ${\times}$ taeda in 199 to 1960 in the denuded forest lands with and after several erosion control works. The soil texture of the sites investigated was SL originated from weathered granitic soil. The former is situated at Py$\ddot{o}$ngchangri, Ky$\ddot{o}$m-my$\ddot{o}$n, Kogs$\ddot{o}$ng-gun, Ch$\ddot{o}$llanam-do (3.63 ha; slope, $17^{\circ}{\sim}41^{\circ}$ soil depth, thin or medium; humidity, dry or optimum; height, 5.66/3.73 ~ 7.63 m; D.B.H., 9.7/8.00 ~ 12.00 cm) and the Latter at changun-long Kwangju-shi (3.50 ha; slope, $12^{\circ}{\sim}23^{\circ}$; soil depth, thin; humidity, dry; height, 10.47/7.3 ~ 12.79 m; D.B.H., 16.94/14.3 ~ 19.4 cm).The sampling areas were 24quadrats ($10m{\times}10m$) in the former area and 12 in the latter expanding from summit to foot. Each sampling trees for hardness test and investigation of root distribution were selected by purposive selection and soil profiles of these trees were made at the downward distance of 50 cm from the trees, at each quadrat. Soil layers of the profile were separated by the distance of 10 cm from the surface (layer I, II, ... ...). Soil hardness was measured with Yamanaka soil hardness tester and indicated as indicated soil hardness at the different soil layers. The distribution of tree root number per unit area in different soil depth was investigated, and the relationship between the soil hardness and the number of tree roots was discussed. The results obtained from the experiments are summarized as follows. 1. Analyses of simple relationship between shear strength and elements of shear strength, water content ($w_o$), void ratio ($e_o$), dry density (${\gamma}_d$) and specific gravity ($G_s$). 1) Negative correlation coefficients were recognized between shear strength and water content. and shear strength and void ratio. 2) Positive correlation coefficients were recognized between shear strength and dry density. 3) The correlation coefficients between shear strength and specific gravity were not significant. 2. Analyses of partial and multiple correlation coefficients between shear strength and the related elements: 1) From the analyses of the partial correlation coefficients among water content ($x_1$), void ratio ($x_2$), and dry density ($x_3$), the direct effect of the water content on shear strength was the highest, and effect on shear strength was in order of void ratio and dry density. Similar trend was recognized from the results of multiple correlation coefficient analyses. 2) Multiple linear regression equations derived from two independent variables, water content ($x_1$ and dry density ($x_2$) were found to be ineffective in estimating shear strength ($\hat{Y}$). However, the simple linear regression equations with an independent variable, water content (x) were highly efficient to estimate shear strength ($\hat{Y}$) with relatively high fitness. 3. A relationship between soil hardness and the distribution of root number: 1) The soil hardness increased proportionally to the soil depth. Negative correlation coefficients were recognized between indicated soil hardness and the number of tree roots in both plantations. 2) The majority of tree roots of Pinus rigida Mill and Pinus rigida ${\times}$ taeda planted in erosion-controlled lands distributed at 20 cm deep from the surface. 3) Simple linear regression equations were derived from indicated hardness (x) and the number of tree roots (Y) to estimate root numbers in both plantations.

  • PDF